Datalogger Programming Options |
Datalogger
Type |
Sampling
Options |
Memory
Capacity |
Battery
Life |
| Levelogger Edge |
Linear (0.125 second to 99 hours), Compressed Linear, Event Based, Schedule, Repeat Schedule, Real Time View , Future Start/Stop |
40,000 sets of readings or up to 120,000 Compressed. Slate or Continuous Mode (see note) |
10 years based on 1 reading per minute |
| Barologger Edge |
Linear (0.125 second to 99 hours), Compressed Linear, Event Based, Schedule, Repeat Schedule, Real Time View, Future Start/Stop |
40,000 sets of readings or up to 120,000 Compressed. Slate or Continuous Mode (see note) |
10 years based on 1 reading per minute |
| Levelogger Junior Edge |
Linear (0.5 second to 99 hours), Real Time View |
40,000 sets of readings in Slate Mode |
5 years based on 1 reading per minute |
| LTC Levelogger Junior |
Linear (5 seconds to 99 hours), Real Time View |
16,000 sets of readings in Slate Mode |
5 years based on 1 reading every 5 minutes |
| Rainlogger |
Event Based (records tips from tipping-bucket rain gauge), Real Time View |
Up to 60,000 tip time logs in Slate Mode |
10 years based on 2 parameters logged every 10 minutes |
| Levelogger Gold |
Linear (0.5 second to 99 hours), Event Based, Schedule, Real Time View, Future Start/Stop |
40,000 sets of readings, Slate or Continuous Mode. |
10 years based on 1 reading per minute |
| Barologger Gold |
Linear (0.5 second to 99 hours), Event Based, Schedule, Real Time View, Future Start/Stop |
40,000 sets of readings, Slate or Continuous Mode. |
10 years based on 1 reading per minute |
| Levelogger Junior |
Linear (0.5 second to 99 hours), Real Time View |
32,000 sets of readings in Slate Mode |
5 years based on 1 reading per minute |