{"id":219711,"date":"2025-12-31T02:57:39","date_gmt":"2025-12-31T02:57:39","guid":{"rendered":"https:\/\/www.solinst.com\/410-peristaltic-pump-instructions\/solinst-410-mk4-peristaltic-pump-operating-instructions\/"},"modified":"2026-05-07T21:01:52","modified_gmt":"2026-05-07T21:01:52","slug":"solinst-410-mk4-peristaltic-pump-operating-instructions","status":"publish","type":"page","link":"https:\/\/www.solinst.com\/en-gb\/products\/groundwater-samplers\/410-peristaltic-pumps\/410-peristaltic-pump-instructions\/solinst-410-mk4-peristaltic-pump-operating-instructions\/","title":{"rendered":"Solinst 410 Mk4 Peristaltic Pump Operating Instructions"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; admin_label=&#8221;H1 and breadcrumbs&#8221; _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;792ca5bd-0808-46bd-9ce7-3bcb8e74f4d3&#8243; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;4b28f470-0d73-4e9d-b92d-e6f41f2cea24&#8243; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.25.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; header_font=&#8221;|700|||||||&#8221; header_font_size=&#8221;36px&#8221; custom_margin=&#8221;||5px|||&#8221; header_text_align_tablet=&#8221;&#8221; header_text_align_phone=&#8221;&#8221; header_text_align_last_edited=&#8221;on|desktop&#8221; header_font_size_tablet=&#8221;30px&#8221; header_font_size_phone=&#8221;26px&#8221; header_font_size_last_edited=&#8221;on|phone&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h1 role=\"heading\" aria-level=\"2\" data-uw-rm-heading=\"level\">410 Mk4 Peristaltic Pump Operating Instructions<\/h1>\n<p>[\/et_pb_text][dsm_breadcrumbs disabled_on=&#8221;on|off|off&#8221; _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; home_icon_text_color=&#8221;#d6d6d6&#8243; global_colors_info=&#8221;{}&#8221;][\/dsm_breadcrumbs][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; admin_label=&#8221;Mobile-Only Nav with Offset&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;4759a92f-4b27-4854-bb2c-299854634e93&#8243; global_module=&#8221;120567&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; width=&#8221;90%&#8221; custom_margin=&#8221;0px||||false|false&#8221; custom_padding=&#8221;0px||||false|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_code admin_label=&#8221;410 Peristaltic Pumps Mobile Nav &#8211; Select Dropdown&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_css_free_form=&#8221;select {||||      font-size: 1em; \/* Adjust font size *\/||      padding: 10px;   \/* Optional: Increase padding for better spacing *\/||      width: 100%;||      box-sizing: border-box;\/* Optional: Adjust width to fit the container *\/||      height: 50px;||}||||    \/* Style for dropdown options (fallback if needed) *\/||select option {||      font-size: 1.2em; \/* Ensures option text matches select styling *\/||      width: 100%;||    }&#8221; global_colors_info=&#8221;{}&#8221;]<select name=\"dropdown\" onchange=\"location = this.value;\"><!-- [et_pb_line_break_holder] --><option value=\"\">410 Peristaltic Pumps Menu<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/multilevel-systems\/403-cmt-multilevel-systems\/\">Peristaltic Pumps Main Page<\/option><!-- [et_pb_line_break_holder] -->  <!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/410-peristaltic-pumps\/get-quote.php\">Get a Quote<\/option><!-- [et_pb_line_break_holder] -->  <!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/Forms\/sol.php\">Send Me Info<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/groundwater-samplers\/410-peristaltic-pumps\/datasheet\/\">Datasheet<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/data\/410.pdf\">&#8211;Download (PDF)<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/groundwater-samplers\/410-peristaltic-pumps\/peristaltic-pump-instructions\/\">Instructions<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/410-mk5-peristaltic-pump-operating-ins-117865\/410-mk5-operating-ins-117865.pdf\">-Mk5 Peristaltic Pump Operating Instructions (PDF)<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/groundwater-samplers\/410-peristaltic-pumps\/peristaltic-pump-instructions\/410-mk4-peristatlic-pump-operating-instructions\/\">-Mk4 Peristaltic Pump Operating Instructions<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/peristaltic-pump\/410-instructions.pdf\">&#8211;Download (PDF)<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/groundwater-samplers\/410-peristaltic-pumps\/peristaltic-pump-instructions\/pump-head-replacement-410-mk4\/\">-Mk4\/Mk3 Pump Head Replacement<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/410-peristaltic-pump-head-replacement-113953\/410-113953.pdf\">&#8211;Download (PDF)<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/groundwater-samplers\/410-peristaltic-pumps\/peristaltic-pump-instructions\/potentiometer-replacement-410-mk4\/\">-Mk4 Potentiometer Replacement<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/410-potentiometer-replacement-109903\/410-potentiometer-replacement.pdf\">&#8211;Download (PDF)<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/groundwater-samplers\/410-peristaltic-pumps\/peristaltic-pump-instructions\/control-board-replacement-model-410-mk4\/\">-Mk4 Control Board Replacement<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/410-peristaltic-pump-control-board-replacement-109708\/410-peristaltic-pump-control-board-replacement.pdf\">&#8211;Download (PDF)<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/groundwater-samplers\/410-peristaltic-pumps\/peristaltic-pump-instructions\/motor-replacement\/\">-Mk4 Motor Replacement<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/410-motor-replacement-114332\/410-motor-replacement.pdf\">&#8211;Download (PDF)<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/groundwater-samplers\/410-peristaltic-pumps\/peristaltic-pump-instructions\/peristaltic-pump-motor-gear-inspection-and-lubrication\/\">-Mk4 Motor Gear Inspection and Lubrication<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/410-gear-inspection-lubrication\/410-gear-inspection-lubrication.pdf\">&#8211;Download (PDF)<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/groundwater-samplers\/410-peristaltic-pumps\/peristaltic-pump-instructions\/410-battery-clip-replacement\/\">-Battery Clip Replacement<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/410-clip-replacement-111799\/410-battery-clip-replacement-111799.pdf\">&#8211;Download (PDF)<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/groundwater-samplers\/410-peristaltic-pumps\/peristaltic-pump-instructions\/peristaltic-pump-12v-battery-holder-instructions\/\">-12V Battery Holder<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/410-12v-battery-holder-114675\/410-12v-battery-holder-114675.pdf\">&#8211;Download (PDF)<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/data\/groundwater-samplers.pdf\">-Solinst Groundwater Samplers (PDF)<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/groundwater-samplers\/410-peristaltic-pumps\/peristaltic-pump-instructions\/potentiometer-replacement-410-mk3\/\">-Mk3 Potentiometer Replacement<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/410-potentiometer-replacement-109903\/410-mk3-potentiometer-replacement.pdf\">&#8211;Download (PDF)<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/groundwater-samplers\/410-peristaltic-pumps\/peristaltic-pump-instructions\/fuse-holder-replacement-model-410-mkiii\/\">-Mk3 Fuse Holder Assembly Replacement<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/410-peristaltic-pump-fuse-holder-assembly-replacement-110734\/410-peristaltic-pump-fuse-holder-assembly-replacement.pdf\">&#8211;Download (PDF)<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/groundwater-samplers\/410-peristaltic-pumps\/peristaltic-pump-instructions\/power-cable-assembly-replacement-410-mk3\/\">-Mk3 Power Cable Assembly Replacement<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/410-peristaltic-pump-power-cable-assembly-replacement-110793\/410-peristaltic-pump-power-cable-assembly-replacement.pdf\">&#8211;Download (PDF)<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/groundwater-samplers\/410-peristaltic-pumps\/peristaltic-pump-instructions\/410-mk3-control-board-replacement\/\">-Mk3 Control Board Replacement<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/410-peristaltic-pump-control-board-replacement-109708\/410-mk3-peristaltic-pump-control-board-replacement.pdf\">&#8211;Download (PDF)<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/groundwater-samplers\/410-peristaltic-pumps\/peristaltic-pump-instructions\/strain-relief-replacement-410-mk3\/\">-Mk3 Strain Relief Replacement<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/410-strain-relief-replacement\/410-strain-relief-replacement-112243.pdf\">&#8211;Download (PDF)<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><\/select>[\/et_pb_code][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; specialty=&#8221;on&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;5a5bca26-a9a5-4e6c-8fca-d64da3bdcd40&#8243; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;1_4&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_menu menu_id=&#8221;402&#8243; admin_label=&#8221;410 Peristaltic Pumps Main Nav&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;242faa89-ac4f-4e46-90fe-505e8c1eab79&#8243; global_module=&#8221;120318&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_menu][et_pb_slider disabled_on=&#8221;on|on|off&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; display_conditions=&#8221;W10=&#8221; link_option_url=&#8221;https:\/\/downloads.solinst.com\/free-shipping?utm_source=solinst&#038;utm_medium=WC-global-sidebar-position1&#038;utm_campaign=free-shipping&#8221; global_module=&#8221;53188&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_slide button_text=&#8221;Advantages of Using Water Flute&#8221; button_link=&#8221;https:\/\/www.solinst.com\/instruments\/solinst-flute\/405-water-flute\/?utm_source=solinst&amp;utm_medium=WC-global-sidebar-position1&amp;utm_campaign=405-water-flute&#8221; use_bg_overlay=&#8221;on&#8221; bg_overlay_color=&#8221;rgba(224,97,0,0.58)&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; background_color=&#8221;#F07C00&#8243; background_enable_color=&#8221;on&#8221; background_image=&#8221;https:\/\/www.solinst.com\/wp-content\/uploads\/2024\/12\/405-water-flute-multilevel-groundwater-system-installation.webp&#8221; background_enable_image=&#8221;on&#8221; background_position=&#8221;top_center&#8221; custom_button=&#8221;on&#8221; button_bg_color=&#8221;#f58025&#8243; button_border_width=&#8221;2px&#8221; button_border_radius=&#8221;20px&#8221; button_font=&#8221;|600|||||||&#8221; background_last_edited=&#8221;on|desktop&#8221; global_colors_info=&#8221;{}&#8221; sticky_transition=&#8221;on&#8221;]<\/p>\n<h2><strong><\/strong><\/h2>\n<h2><strong><\/strong><\/h2>\n<h2><strong><\/strong><\/h2>\n<p>&nbsp;<\/p>\n<h2>Depth Discrete Groundwater Monitoring<\/h2>\n<p><b>Reduce Costs and Field Time<\/b><\/p>\n<p>[\/et_pb_slide][\/et_pb_slider][et_pb_slider disabled_on=&#8221;on|on|on&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; link_option_url=&#8221;https:\/\/connect.spohr-messtechnik.de\/spohr-10-percent-off?utm_source=solinst&#038;utm_medium=WC-global-sidebar-position2&#038;utm_campaign=spohr-lw-wlm&#8221; disabled=&#8221;on&#8221; global_module=&#8221;53561&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_slide heading=&#8221;Spohr Low Cost Water Level Meters&#8221; button_text=&#8221;10% OFF&#8221; button_link=&#8221;https:\/\/connect.spohr-messtechnik.de\/spohr-10-percent-off?utm_source=solinst&amp;utm_medium=WC-global-sidebar-position2&amp;utm_campaign=spohr-lw-wlm&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; header_text_color=&#8221;#000000&#8243; background_color=&#8221;RGBA(255,255,255,0)&#8221; background_enable_color=&#8221;on&#8221; background_image=&#8221;https:\/\/www.solinst.com\/wp-content\/uploads\/2025\/11\/spohr-lightweight-water-level-meter-10off-965&#215;500-1.webp&#8221; background_enable_image=&#8221;on&#8221; background_size=&#8221;contain&#8221; custom_button=&#8221;on&#8221; button_bg_color=&#8221;#f58025&#8243; button_border_width=&#8221;2px&#8221; button_border_radius=&#8221;20px&#8221; button_font=&#8221;|600|||||||&#8221; header_text_shadow_style=&#8221;preset3&#8243; global_colors_info=&#8221;{}&#8221; sticky_transition=&#8221;on&#8221;]<\/p>\n<h2\/>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>[\/et_pb_slide][\/et_pb_slider][\/et_pb_column][et_pb_column type=&#8221;3_4&#8243; specialty_columns=&#8221;3&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_row_inner _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;3d68e16c-1ed2-447f-b17f-a63c20af3cf6&#8243; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner saved_specialty_column_type=&#8221;3_4&#8243; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][dsm_icon_list icon_font_size=&#8221;30px&#8221; list_alignment=&#8221;flex-end&#8221; text_indent=&#8221;10px&#8221; list_alignment_tablet=&#8221;flex-end&#8221; list_alignment_phone=&#8221;flex-start&#8221; list_alignment_last_edited=&#8221;on|desktop&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;|600|||||||&#8221; link_option_url_new_window=&#8221;on&#8221; global_colors_info=&#8221;{}&#8221;][dsm_icon_list_child text=&#8221;410 Mk4 Peristaltic Pump Operating Instructions PDF&#8221; font_icon=&#8221;&#xf1c1;||fa||900&#8243; icon_color=&#8221;#ff8500&#8243; url=&#8221;https:\/\/www.solinst.com\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/peristaltic-pump\/410-instructions.pdf&#8221; url_new_window=&#8221;on&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; icon_color__hover_enabled=&#8221;on|hover&#8221; icon_color__hover=&#8221;#828282&#8243; text_text_color__hover_enabled=&#8221;on|hover&#8221; text_text_color__hover=&#8221;#7a7a7a&#8221;][\/dsm_icon_list_child][\/dsm_icon_list][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;3676f7e6-7b83-4698-94ce-2cc9fa9ae43d&#8221; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner saved_specialty_column_type=&#8221;3_4&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text _builder_version=&#8221;4.27.4&#8243; hover_enabled=&#8221;0&#8243; border_width_all=&#8221;1px&#8221; border_color_all=&#8221;rgba(0,0,0,0.23)&#8221; global_colors_info=&#8221;{}&#8221; _module_preset=&#8221;e910b435-fe18-45d2-b351-bda808b1a267&#8243; sticky_enabled=&#8221;0&#8243;]<\/p>\n<h3><strong>IMPORTANT<\/strong><\/h3>\n<ul>\n<li>The pump should be operated in an upright position, sitting on the rubber feet on the bottom of the pump (handle and dial on top).<\/li>\n<li>Pump is water resistant but not waterproof. Do not submerge in water. <\/li>\n<li>Pump is not designed for long-term continuous uninterrupted use.<\/li>\n<li>To avoid motor damage due to overheating, allow pump to cool fully at least every 7\u20138 hours, or more often under high ambient heat conditions.<\/li>\n<li>Pumping rates will decrease with elevation, and as the amount of lift increases.<\/li>\n<li>Replace the tubing regularly. Worn tubing can cause the pump to be inefficient. This will show as a limited ability to lift water. If the tubing looks worn, flattened or cracked, replace the tubing.   <\/li>\n<li>If used in cold weather, ensure that there is no ice in the tubing before starting the pump.<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/peristaltic-pump\/images\/410-labelled-1x.jpg\" alt=\"solinst peristaltic pumps diagram\" width=\"500\" title=\"Solinst Peristaltic Pumps Diagram\"><\/p>\n<p>Solinst Model 410 Peristaltic Pump (#112981)<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.27.4&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2>Power Requirements for Solinst Peristaltic Pumps<\/h2>\n<p>The pump operates from an external 12V DC power supply such as a car, lorry or marine 12 volt battery that can supply at least 3\u20135 amps at maximum draw. The pump has a 3 m (10 ft) power cable with connector clips for direct battery connection. <\/p>\n<p>For more portable, short duration sampling events, attach the optional 12V Battery Holder (see separate instructions).<\/p>\n<p>The power cable clips are oversized for use with automotive batteries. The red clip connects to the positive (+) battery terminal, black to negative (-) battery terminal. If the battery is connected with reverse polarity the pump will not be harmed, but it will NOT operate until the polarity is connected correctly.  <\/p>\n<p>A circuit breaker reset button is located on the side of the pump. In the event the pump amperage exceeds 10 amps, the circuit breaker will trip (button pops out) and turn the pump off. To reset the breaker, simply press the reset button back in to regain operation of the pump.  <\/p>\n<p>If the pump is to be powered by a typical 45Ah vehicle battery for more than 3 continuous hours, start vehicle and run for 15 minutes to recharge the battery.<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.27.4&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2>Operation<\/h2>\n<ul>\n<li>The Solinst Peristaltic Pump has an integral forward\/reverse, variable flow dial with an OFF position, which has a central detent. When turning the unit OFF, ensure you feel the dial snap into position. <\/li>\n<li>The pump should always be kept with the control in the OFF position when it is being attached to a power source or stored.<\/li>\n<li>Once attached to a power source, turn the dial in the direction required and adjust the flow as desired.<\/li>\n<li>The standard 5\/8&#8243; (16 mm) OD medical grade silicone tubing can be attached to 1\/2&#8243; (13 mm) OD down-hole sample tubing and gives sample rates up to 3.2 L\/min.<\/li>\n<li>The 3\/8&#8243; (10 mm) OD silicone tubing and adaptor kit allows the use of 1\/4&#8243; (6 mm) OD down-hole sample tubing, giving sampling rates as low as 40 mL\/min.<\/li>\n<\/ul>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.16&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<ol>\n<li>Ensure that the chosen silicone tubing has been properly installed in the pump head.<\/li>\n<li>Connect one end of the silicone tubing to the down-hole sample line. See diagram below. <\/li>\n<li>Either connect the other end of the silicone tubing to a discharge tube, or simply discharge out of this end of the tubing. See diagram below. <\/li>\n<li>Connect the negative (black) battery clip to the negative terminal post on a 12V DC battery and the positive (red) battery clip to the positive terminal.<\/li>\n<li> Turn the dial in the direction required and adjust the flow as desired.<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/peristaltic-pump\/images\/410-setup-1x.jpg\" alt=\"solinst peristaltic pumps diagram showing sampling setup\" width=\"500\" title=\"Solinst Peristaltic Pump Sampling Setup\"><\/p>\n<p>Solinst Model 410 Peristaltic Pump Setup<\/p>\n<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.16&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<table>\n<tr>\n<th>Down-hole Tubing Specifications<\/th>\n<\/tr>\n<tr>\n<th>Use with Standard 5\/8&#8243; OD Silicon Tubing<\/th>\n<\/tr>\n<tr>\n<td>1\/2&#8243; OD x 3\/8&#8243; ID LDPE (100 ft coil)<\/td>\n<td>109490<\/td>\n<\/tr>\n<tr>\n<td>1\/2&#8243; OD x 3\/8&#8243; ID LDPE (250 ft coil)<\/td>\n<td>109489<\/td>\n<\/tr>\n<tr>\n<td>1\/2&#8243; OD x 3\/8&#8243; ID LDPE (500 ft coil)<\/td>\n<td>109488<\/td>\n<\/tr>\n<tr>\n<th>Use with Optional 3\/8&#8243; OD (with Adaptor Kit) Silicon Tubing<\/th>\n<\/tr>\n<tr>\n<td>1\/4&#8243; OD x 0.17&#8243; ID LDPE Tubing (100 ft coil)<\/td>\n<td>109465<\/td>\n<\/tr>\n<tr>\n<td>1\/4&#8243; OD x 0.17&#8243; ID LDPE Tubing (250 ft coil)<\/td>\n<td>109464<\/td>\n<\/tr>\n<tr>\n<td>1\/4&#8243; OD x 0.17&#8243; ID LDPE Tubing (500 ft coil)<\/td>\n<td>109463<\/td>\n<\/tr>\n<tr>\n<td>1\/4&#8243; OD x 0.17&#8243; ID PTFE-lined LDPE Tubing (100 ft coil)<\/td>\n<td>109454<\/td>\n<\/tr>\n<tr>\n<td>1\/4&#8243; OD x 0.17&#8243; ID PTFE-lined LDPE Tubing (250 ft coil)<\/td>\n<td>109444<\/td>\n<\/tr>\n<\/table>\n<p>[\/et_pb_text][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;3676f7e6-7b83-4698-94ce-2cc9fa9ae43d&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner saved_specialty_column_type=&#8221;3_4&#8243; _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_button button_url=&#8221;https:\/\/www.solinst.com\/products\/groundwater-samplers\/410-peristaltic-pumps\/get-quote.php&#8221; button_text=&#8221;Get Quote&#8221; admin_label=&#8221;410 get quote&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;c9e00792-1360-4998-8cf9-5f6772c944ba&#8221; custom_padding=&#8221;6px|47px|6px|47px|false|false&#8221; global_module=&#8221;120346&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;3676f7e6-7b83-4698-94ce-2cc9fa9ae43d&#8221; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner saved_specialty_column_type=&#8221;3_4&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text _builder_version=&#8221;4.27.4&#8243; hover_enabled=&#8221;0&#8243; border_width_all=&#8221;1px&#8221; border_color_all=&#8221;rgba(0,0,0,0.23)&#8221; global_colors_info=&#8221;{}&#8221; _module_preset=&#8221;e910b435-fe18-45d2-b351-bda808b1a267&#8243; sticky_enabled=&#8221;0&#8243;]<\/p>\n<p><strong>Note:<\/strong><br \/>Always disconnect from the power source while the pump head cover is removed.<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.27.4&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2>Changing or Installing 5\/8&#8243; Silicone Tubing<\/h2>\n<p><img decoding=\"async\" src=\"\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/peristaltic-pump\/images\/410-pump-w-adaptor-kit-1-1x.jpg\" alt=\"solinst peristaltic pump with tubing adaptor kit installed\" width=\"360\" title=\"Solinst 410 Peristaltic Pump - Pump Head Illustration\">[\/et_pb_text][et_pb_text _builder_version=&#8221;4.16&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<ol>\n<li>To install or replace the tubing, disconnect the pump from its power supply, then undo the four thumbscrews on the pump head (clear plastic end). Remove the pump head cover. <\/li>\n<li>Manually rotate the pump impeller in any direction while gently pulling on the tubing to pull it out of the pump head.<\/li>\n<li>Position the new tubing around the impeller in a &#8220;U&#8221; shape with equal lengths. Turn the impeller to the 6 and 12 o&#8217;clock position and push the right hand tubing into the tubing pathway, holding near the bottom. Rotate the impeller clockwise until tubing is in place. Push the left half of the tubing into place and rotate the impeller.   <\/li>\n<li>Reposition the pump head cover and screw firmly in place, but only finger tight. Do not use a spanner or overtighten. <\/li>\n<\/ol>\n<h2>Installing Adapter Kit &amp; 3\/8&#8243; Tubing (#113913)<\/h2>\n<h3><strong>Includes<\/strong>:<\/h3>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.16&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<ul>\n<li>3 ft of 3\/8\u201d OD Silicone Tubing <\/li>\n<li>1 Pump Head Insert<\/li>\n<li>2 Tubing Inserts<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/peristaltic-pump\/images\/410-components-1x.jpg\" alt=\"solinst 3\/8 inch tubing adapter kit for peristaltic pump\" width=\"500\" title=\"3\/8 inch Tubing Adaptor Kit For Peristaltic Pump\"><\/p>\n<p><img decoding=\"async\" src=\"\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/peristaltic-pump\/images\/410-pump-w-adaptor-kit-2-1x.jpg\" alt=\"solinst peristaltic pump with tubing adaptor kit installed\" width=\"360\" title=\"Solinst 410 Peristaltic Pump - Pump Head Illustration\"><\/p>\n<p>Peristaltic Pump with Tubing Adaptor Kit Installed<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.27.4&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<ol>\n<li>Disconnect the pump from the power supply, then undo the four thumbscrews on the pump head (clear plastic end). Remove the pump head cover. Remove the existing tubing (see step #2 above).  <\/li>\n<li>Slide the tubing inserts into the pump head tubing inlet\/outlets.<\/li>\n<li>Make a &#8220;U&#8221; shape with the white plastic pump head insert and place around the tubing pathway in the pump head. The angled cutouts on the two corners of the insert face outwards. <\/li>\n<li>Position the new tubing around the impeller, following instruction #3 above.<\/li>\n<li>Re-position the pump head cover and screw it firmly in place, but only finger tight. Do not use a spanner or overtighten. <\/li>\n<\/ol>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.27.4&#8243; hover_enabled=&#8221;0&#8243; border_width_all=&#8221;1px&#8221; border_color_all=&#8221;rgba(0,0,0,0.23)&#8221; global_colors_info=&#8221;{}&#8221; sticky_enabled=&#8221;0&#8243; _module_preset=&#8221;e910b435-fe18-45d2-b351-bda808b1a267&#8243;]<\/p>\n<h2><a href=\"..\/..\/index.php\" title=\"Solinst Peristaltic Pumps\">Peristaltic Pump<\/a> Maintenance<\/h2>\n<ul>\n<li>Remove tubing when stored.<\/li>\n<li>Replace the tubing regularly.<\/li>\n<li>To avoid motor damage due to overheating, allow pump to cool fully at least every 7\u20138 hours, or more often under high ambient heat conditions.<\/li>\n<li>In the event of a tripped circuit breaker, simply press the reset button on the side of the pump to regain operation of the pump.<\/li>\n<li>With heavy usage we recommend opening the motor to inspect the gears periodically. Clean the gears and add grease if necessary. Contact Solinst for instructions.  <\/li>\n<\/ul>\n<p>[\/et_pb_text][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;3676f7e6-7b83-4698-94ce-2cc9fa9ae43d&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner saved_specialty_column_type=&#8221;3_4&#8243; _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_button button_url=&#8221;https:\/\/www.solinst.com\/products\/groundwater-samplers\/410-peristaltic-pumps\/get-quote.php&#8221; button_text=&#8221;Get Quote&#8221; admin_label=&#8221;410 get quote&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;c9e00792-1360-4998-8cf9-5f6772c944ba&#8221; custom_padding=&#8221;6px|47px|6px|47px|false|false&#8221; global_module=&#8221;120346&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;3676f7e6-7b83-4698-94ce-2cc9fa9ae43d&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner saved_specialty_column_type=&#8221;3_4&#8243; _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_heading title=&#8221;Related Products&#8221; _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; title_level=&#8221;h2&#8243; title_font=&#8221;|700|||||||&#8221; title_font_size=&#8221;22px&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_heading][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner column_structure=&#8221;1_2,1_2&#8243; disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; border_width_bottom=&#8221;1px&#8221; border_color_bottom=&#8221;#d3d3d3&#8243; global_module=&#8221;119863&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner type=&#8221;1_2&#8243; _builder_version=&#8221;4.25.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_image src=&#8221;https:\/\/www.solinst.com\/wp-content\/uploads\/2025\/09\/415-12v-submersible-pump.webp&#8221; alt=&#8221;solinst model 415 12v submersible pump&#8221; title_text=&#8221;Solinst Model 415 12V Submersible Pump&#8221; url=&#8221;https:\/\/www.solinst.com\/products\/level-measurement-devices\/103-tag-line\/&#8221; align=&#8221;center&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; border_color_all=&#8221;#bcbcbc&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][\/et_pb_column_inner][et_pb_column_inner type=&#8221;1_2&#8243; _builder_version=&#8221;4.25.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; header_2_line_height=&#8221;1.3em&#8221; custom_margin=&#8221;60px||||false|false&#8221; custom_margin_tablet=&#8221;0px||||false|false&#8221; custom_margin_phone=&#8221;0px||||false|false&#8221; custom_margin_last_edited=&#8221;on|desktop&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2><strong>415 12V Submersible Pump<\/strong><\/h2>\n<p>The <a href=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/415-12v-submersible-pump\/415.php\" title=\"Solinst 12V Submersible Pump\"><strong>Solinst 12V Submersible Pump<\/strong><\/a> provides an efficient means of purging and obtaining groundwater samples from 2&#8243; OD monitoring wells. The compact pump can sample from depths of 36.5 m (120 ft) below ground surface, and is easy to adjust the flow rates up to 13.5 L\/min (3.6 US gpm) in shallower applications. <\/p>\n<p>[\/et_pb_text][et_pb_button button_url=&#8221;https:\/\/www.solinst.com\/products\/groundwater-samplers\/415-12v-submersible-pump\/415.php&#8221; button_text=&#8221;12V Submersible Pump&#8221; button_alignment=&#8221;right&#8221; button_alignment_tablet=&#8221;center&#8221; button_alignment_phone=&#8221;center&#8221; button_alignment_last_edited=&#8221;on|phone&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_button=&#8221;on&#8221; button_text_size=&#8221;20px&#8221; button_text_color=&#8221;#000000&#8243; button_bg_color=&#8221;#FFFFFF&#8221; button_border_color=&#8221;#ff8500&#8243; button_border_radius=&#8221;20px&#8221; button_icon=&#8221;&#x3d;||divi||400&#8243; custom_padding=&#8221;0px|||||&#8221; button_text_size_tablet=&#8221;18px&#8221; button_text_size_phone=&#8221;16px&#8221; button_text_size_last_edited=&#8221;on|desktop&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner column_structure=&#8221;1_2,1_2&#8243; disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; border_width_bottom=&#8221;1px&#8221; border_color_bottom=&#8221;#d3d3d3&#8243; global_module=&#8221;119816&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner type=&#8221;1_2&#8243; _builder_version=&#8221;4.25.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_image src=&#8221;https:\/\/www.solinst.com\/wp-content\/uploads\/2025\/09\/800m-mini-low-pressure-packer.webp&#8221; alt=&#8221;solinst model 800m mini low pressure packer&#8221; title_text=&#8221;Solinst Model 800M Mini Low Pressure Packer&#8221; url=&#8221;https:\/\/www.solinst.com\/products\/level-measurement-devices\/103-tag-line\/&#8221; align=&#8221;center&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; border_color_all=&#8221;#bcbcbc&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][\/et_pb_column_inner][et_pb_column_inner type=&#8221;1_2&#8243; _builder_version=&#8221;4.25.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; header_2_line_height=&#8221;1.3em&#8221; custom_margin=&#8221;60px||||false|false&#8221; custom_margin_tablet=&#8221;0px||||false|false&#8221; custom_margin_phone=&#8221;0px||||false|false&#8221; custom_margin_last_edited=&#8221;on|desktop&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2><strong>800M Mini Packer<\/strong><\/h2>\n<p>The <a href=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/800-low-pressure-packers\/index.php\" title=\"800M Mini Packer\"><strong>800M Mini Packer<\/strong><\/a> is 1 ft in length and is designed to fit in nominal 2&#8243; OD monitoring wells to temporarily isolate discrete zones for groundwater monitoring and sampling applications \u2013 available as a single and straddle packer setup.<\/p>\n<p>[\/et_pb_text][et_pb_button button_url=&#8221;https:\/\/www.solinst.com\/products\/groundwater-samplers\/800-low-pressure-packers\/index.php&#8221; button_text=&#8221;Mini Low Pressure Groundwater Packer&#8221; button_alignment=&#8221;right&#8221; button_alignment_tablet=&#8221;center&#8221; button_alignment_phone=&#8221;center&#8221; button_alignment_last_edited=&#8221;on|phone&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_button=&#8221;on&#8221; button_text_size=&#8221;20px&#8221; button_text_color=&#8221;#000000&#8243; button_bg_color=&#8221;#FFFFFF&#8221; button_border_color=&#8221;#ff8500&#8243; button_border_radius=&#8221;20px&#8221; button_icon=&#8221;&#x3d;||divi||400&#8243; custom_padding=&#8221;0px|||||&#8221; button_text_size_tablet=&#8221;18px&#8221; button_text_size_phone=&#8221;16px&#8221; button_text_size_last_edited=&#8221;on|desktop&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner column_structure=&#8221;1_2,1_2&#8243; disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; border_width_bottom=&#8221;1px&#8221; border_color_bottom=&#8221;#d3d3d3&#8243; global_module=&#8221;119793&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner type=&#8221;1_2&#8243; _builder_version=&#8221;4.25.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_image src=&#8221;https:\/\/www.solinst.com\/wp-content\/uploads\/2025\/09\/880-well-mount-field-table.webp&#8221; alt=&#8221;solinst model 880 well mount field table&#8221; title_text=&#8221;Solinst Model 880 Well Mount Field Table&#8221; url=&#8221;https:\/\/www.solinst.com\/products\/level-measurement-devices\/103-tag-line\/&#8221; align=&#8221;center&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; border_color_all=&#8221;#bcbcbc&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][\/et_pb_column_inner][et_pb_column_inner type=&#8221;1_2&#8243; _builder_version=&#8221;4.25.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; header_2_line_height=&#8221;1.3em&#8221; custom_margin=&#8221;60px||||false|false&#8221; custom_margin_tablet=&#8221;0px||||false|false&#8221; custom_margin_phone=&#8221;0px||||false|false&#8221; custom_margin_last_edited=&#8221;on|desktop&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2><strong>Make Your Life Easier In The Field<\/strong><\/h2>\n<p>Consider making your life easier in the field by ordering one of our convenient <a href=\"https:\/\/www.solinst.com\/products\/field-equipment\/880-field-table\/field-table.php\" title=\"Solinst Field Tables\"><strong>Field Tables<\/strong><\/a>. We have two models available, Well-mount and Stand-alone, to keep your equipment organised and provide a clean, sturdy surface to hold your field tools. <\/p>\n<p>Well-mount Field Table &#8211; 115209<br \/>Stand-alone Field Table &#8211; 115312<\/p>\n<p>[\/et_pb_text][et_pb_button button_url=&#8221;https:\/\/www.solinst.com\/products\/field-equipment\/880-field-table\/field-table.php&#8221; button_text=&#8221;Convenient Field Tables&#8221; button_alignment=&#8221;right&#8221; button_alignment_tablet=&#8221;center&#8221; button_alignment_phone=&#8221;center&#8221; button_alignment_last_edited=&#8221;on|phone&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_button=&#8221;on&#8221; button_text_size=&#8221;20px&#8221; button_text_color=&#8221;#000000&#8243; button_bg_color=&#8221;#FFFFFF&#8221; button_border_color=&#8221;#ff8500&#8243; button_border_radius=&#8221;20px&#8221; button_icon=&#8221;&#x3d;||divi||400&#8243; custom_padding=&#8221;0px|||||&#8221; button_text_size_tablet=&#8221;18px&#8221; button_text_size_phone=&#8221;16px&#8221; button_text_size_last_edited=&#8221;on|desktop&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][\/et_pb_column][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; admin_label=&#8221;Adobe Analytics Code&#8221; _builder_version=&#8221;4.27.0&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;||4px|||&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.27.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_code admin_label=&#8221;AA Code for this page&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]<!-- SiteCatalyst code version: H.21. Copyright 1996-2010 Adobe, Inc. All Rights Reserved More info available at http:\/\/www.omniture.com --><!-- [et_pb_line_break_holder] --><script language=\"JavaScript\" type=\"text\/javascript\" src=\"\/\/www.solinst.com\/s_code.js\"><\/script><!-- [et_pb_line_break_holder] --><script language=\"JavaScript\" type=\"text\/javascript\"><!--<!-- [et_pb_line_break_holder] -->s.pageName=\"410 power requirements and operation\"<!-- [et_pb_line_break_holder] -->s.server=\"\"<!-- [et_pb_line_break_holder] -->s.channel=\"products\"<!-- [et_pb_line_break_holder] -->s.pageType=\"\"<!-- [et_pb_line_break_holder] -->s.prop1=\"groundwater samplers\"<!-- [et_pb_line_break_holder] -->s.prop2=\"410 peristalic pump\"<!-- [et_pb_line_break_holder] -->s.prop3=\"instructions\"<!-- [et_pb_line_break_holder] -->s.prop4=\"410 operating instructions\"<!-- [et_pb_line_break_holder] -->s.prop5=\"410 power requirements and operation\"<!-- [et_pb_line_break_holder] -->s.prop6=\"\"<!-- [et_pb_line_break_holder] -->s.prop7=\"\"<!-- [et_pb_line_break_holder] -->s.prop8=\"\"<!-- [et_pb_line_break_holder] -->s.prop9=\"\"<!-- [et_pb_line_break_holder] -->s.prop10=\"\"<!-- [et_pb_line_break_holder] -->s.prop11=\"\"<!-- [et_pb_line_break_holder] -->s.prop12=\"\"<!-- [et_pb_line_break_holder] -->s.prop13=\"\"<!-- [et_pb_line_break_holder] -->s.prop14=\"\"<!-- [et_pb_line_break_holder] -->s.prop15=\"\"<!-- [et_pb_line_break_holder] -->s.prop16=\"\"<!-- [et_pb_line_break_holder] -->s.prop17=\"\"<!-- [et_pb_line_break_holder] -->s.prop18=\"\"<!-- [et_pb_line_break_holder] -->s.prop19=\"\"<!-- [et_pb_line_break_holder] -->s.prop20=\"\"<!-- [et_pb_line_break_holder] -->s.prop21=\"\"<!-- [et_pb_line_break_holder] -->s.prop22=\"\"<!-- [et_pb_line_break_holder] -->s.prop23=\"\"<!-- [et_pb_line_break_holder] -->s.prop24=\"\"<!-- [et_pb_line_break_holder] -->s.prop25=\"\"<!-- [et_pb_line_break_holder] -->s.prop26=\"\"<!-- [et_pb_line_break_holder] -->s.prop27=\"\"<!-- [et_pb_line_break_holder] -->s.prop28=\"\"<!-- [et_pb_line_break_holder] -->s.prop29=\"\"<!-- [et_pb_line_break_holder] -->s.prop30=\"\"<!-- [et_pb_line_break_holder] -->s.prop31=\"\"<!-- [et_pb_line_break_holder] -->s.prop32=\"\"<!-- [et_pb_line_break_holder] -->s.prop33=\"\"<!-- [et_pb_line_break_holder] -->s.hier1=\"solinst:products:groundwater samplers:410 peristalic pump:instructions:410 operating instructions:410 power requirements and operation\"<!-- [et_pb_line_break_holder] --><!-- [et_pb_line_break_holder] -->\/* Conversion Variables *\/<!-- [et_pb_line_break_holder] -->s.campaign=\"\"<!-- [et_pb_line_break_holder] -->s.events=\"\"<!-- [et_pb_line_break_holder] -->s.eVar1=\"\"<!-- [et_pb_line_break_holder] -->s.eVar2=\"\"<!-- [et_pb_line_break_holder] -->s.eVar3=\"\"<!-- [et_pb_line_break_holder] -->s.eVar4=\"\"<!-- [et_pb_line_break_holder] -->s.eVar5=\"\"<!-- [et_pb_line_break_holder] -->s.eVar6=\"\"<!-- [et_pb_line_break_holder] -->s.eVar7=\"\"<!-- [et_pb_line_break_holder] -->s.eVar8=\"\"<!-- [et_pb_line_break_holder] -->s.eVar9=\"\"<!-- [et_pb_line_break_holder] -->s.eVar10=\"\"<!-- [et_pb_line_break_holder] -->s.eVar11=\"\"<!-- [et_pb_line_break_holder] -->s.eVar12=\"\"<!-- [et_pb_line_break_holder] -->s.eVar13=\"\"<!-- [et_pb_line_break_holder] -->s.eVar14=\"\"<!-- [et_pb_line_break_holder] -->s.eVar15=\"\"<!-- [et_pb_line_break_holder] -->s.eVar16=\"\"<!-- [et_pb_line_break_holder] -->s.eVar17=\"\"<!-- [et_pb_line_break_holder] -->s.state=\"\"<!-- [et_pb_line_break_holder] -->s.zip=\"\"<!-- [et_pb_line_break_holder] -->\/************* DO NOT ALTER ANYTHING BELOW THIS LINE ! **************\/<!-- [et_pb_line_break_holder] -->var s_code=s.t();if(s_code)document.write(s_code)\/\/--><\/script><!-- [et_pb_line_break_holder] --><script language=\"JavaScript\" type=\"text\/javascript\"><!--<!-- [et_pb_line_break_holder] -->if(navigator.appVersion.indexOf('MSIE')>=0)document.write(unescape('%3C')+'!-'+'-')<!-- [et_pb_line_break_holder] -->\/\/--><\/script><!-- [et_pb_line_break_holder] --><noscript><!-- [et_pb_line_break_holder] -->  <a href=\"https:\/\/www.omniture.com\" title=\"Web Analytics\"><!-- [et_pb_line_break_holder] -->    <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/solinst.d2.sc.omtrdc.net\/b\/ss\/solinst-prod\/1\/H.21--NS\/0\" height=\"1\" width=\"1\" border=\"0\" alt=\"\"><!-- [et_pb_line_break_holder] -->  <\/a><!-- [et_pb_line_break_holder] --><\/noscript><!-- [et_pb_line_break_holder] --><!--\/DO NOT REMOVE\/--><!-- [et_pb_line_break_holder] --><!-- End SiteCatalyst code version: H.21. -->[\/et_pb_code][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>410 Mk4 Peristaltic Pump Operating Instructions<div class=\"et_pb_module dsm_breadcrumbs dsm_breadcrumbs_0\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module_inner\">\n\t\t\t\t\t<nav class=\"dsm_breadcrumbs_wrap\">\n\t\t\t\t<ul class=\"dsm_breadcrumbs\" itemscope itemtype=\"https:\/\/schema.org\/BreadcrumbList\">\t\t\t<li class=\"dsm_breadcrumbs_item dsm_home_item dsm_home_item_custom\" itemprop=\"itemListElement\" itemscope\n\t\t\titemtype=\"https:\/\/schema.org\/ListItem\">\n\t\t\t\t<a href=\"https:\/\/www.solinst.com\/en-gb\/\" itemprop=\"item\" target=\"\">\n\t\t\t\t\t<span class='dsm_home_text_wrapper'>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"et-pb-icon dsm_home_icon\">\ue009<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"dsm_home_text\" itemprop=\"name\">\n\t\t\t\t\t\t\t\tHome\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t<\/a>\n\t\t\t\t<meta itemprop=\"position\" content=\"1\" \/>\n\t\t\t<\/li>\n\n\t\t<li class=\"dsm_breadcrumbs_separator\"> <span class=\"et-pb-icon dsm_separator_icon\">5<\/span><\/li><\/ul>\n\t\t\t<\/nav>\n\t\t\t\t<\/div>\n\t\t\t<\/div> &nbsp; Depth Discrete Groundwater Monitoring Reduce Costs and Field Time &nbsp; &nbsp; &nbsp;<div class=\"et_pb_module dsm_icon_list dsm_icon_list_0\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module_inner\">\n\t\t\t\t\t<ul class=\"dsm_icon_list_items dsm_icon_list_ltr_direction dsm_icon_list_layout_vertical\"><li class=\"dsm_icon_list_child dsm_icon_list_child_0\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<a href=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/410-peristaltic-pumps\/operating-instructions\/peristaltic-pump\/410-instructions.pdf\" target=\"_blank\"><span class=\"dsm_icon_list_wrapper\"><span class=\"dsm_icon_list_icon\">\uf1c1<\/span><\/span><span class=\"dsm_icon_list_text\">410 Mk4 Peristaltic Pump Operating Instructions PDF<\/span><\/a>\n\t\t\t<\/li><\/ul>\n\t\t\t\t<\/div>\n\t\t\t<\/div>IMPORTANT The pump should be operated in an upright position, sitting on the rubber feet on the bottom of the pump (handle and dial on top). Pump is water resistant but not waterproof. Do not submerge in water. Pump is not designed for long-term continuous uninterrupted use. To avoid motor damage due to overheating, allow pump to cool fully at least every 7\u20138 hours, or more often under high ambient heat conditions. Pumping rates will decrease with elevation, and as the amount of lift increases. Replace the tubing regularly. Worn tubing can cause the pump to be inefficient. This will show as a limited ability to lift water. If the tubing looks worn, flattened or cracked, replace the tubing. If used in cold weather, ensure that there is no ice in the tubing before starting the pump. Solinst Model 410 Peristaltic Pump (#112981)Power Requirements for Solinst Peristaltic Pumps [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":219685,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"folder":[412],"class_list":["post-219711","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.5 (Yoast SEO v27.5) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Solinst 410 MK4 Peristaltic Pump Operating Instructions<\/title>\n<meta name=\"description\" content=\"Solinst Peristaltic Pump has an integral Forward\/Reverse, variable flow dial with an OFF position, providing flexibility during Peristaltic Pump Sampling operation.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.solinst.com\/en-gb\/products\/groundwater-samplers\/410-peristaltic-pumps\/410-peristaltic-pump-instructions\/solinst-410-mk4-peristaltic-pump-operating-instructions\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Solinst 410 Mk4 Peristaltic Pump Operating Instructions\" \/>\n<meta property=\"og:description\" content=\"Find essential Peristaltic Pump Mk4 operating instructions to optimise your equipment&#039;s performance and ensure proper handling.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solinst.com\/en-gb\/products\/groundwater-samplers\/410-peristaltic-pumps\/410-peristaltic-pump-instructions\/solinst-410-mk4-peristaltic-pump-operating-instructions\/\" \/>\n<meta property=\"og:site_name\" content=\"Solinst Groundwater and Surface Water Monitoring Instrumentation, Water Level Meters, Interface Meters, Dataloggers\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-07T21:01:52+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/solinst.d2.sc.omtrdc.net\/b\/ss\/solinst-prod\/1\/H.21--NS\/0\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"18 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/products\\\/groundwater-samplers\\\/410-peristaltic-pumps\\\/410-peristaltic-pump-instructions\\\/solinst-410-mk4-peristaltic-pump-operating-instructions\\\/\",\"url\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/products\\\/groundwater-samplers\\\/410-peristaltic-pumps\\\/410-peristaltic-pump-instructions\\\/solinst-410-mk4-peristaltic-pump-operating-instructions\\\/\",\"name\":\"Solinst 410 MK4 Peristaltic Pump Operating Instructions\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/products\\\/groundwater-samplers\\\/410-peristaltic-pumps\\\/410-peristaltic-pump-instructions\\\/solinst-410-mk4-peristaltic-pump-operating-instructions\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/products\\\/groundwater-samplers\\\/410-peristaltic-pumps\\\/410-peristaltic-pump-instructions\\\/solinst-410-mk4-peristaltic-pump-operating-instructions\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/solinst.d2.sc.omtrdc.net\\\/b\\\/ss\\\/solinst-prod\\\/1\\\/H.21--NS\\\/0\",\"datePublished\":\"2025-12-31T02:57:39+00:00\",\"dateModified\":\"2026-05-07T21:01:52+00:00\",\"description\":\"Solinst Peristaltic Pump has an integral Forward\\\/Reverse, variable flow dial with an OFF position, providing flexibility during Peristaltic Pump Sampling operation.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/products\\\/groundwater-samplers\\\/410-peristaltic-pumps\\\/410-peristaltic-pump-instructions\\\/solinst-410-mk4-peristaltic-pump-operating-instructions\\\/#breadcrumb\"},\"inLanguage\":\"en-gb\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/products\\\/groundwater-samplers\\\/410-peristaltic-pumps\\\/410-peristaltic-pump-instructions\\\/solinst-410-mk4-peristaltic-pump-operating-instructions\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-gb\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/products\\\/groundwater-samplers\\\/410-peristaltic-pumps\\\/410-peristaltic-pump-instructions\\\/solinst-410-mk4-peristaltic-pump-operating-instructions\\\/#primaryimage\",\"url\":\"https:\\\/\\\/solinst.d2.sc.omtrdc.net\\\/b\\\/ss\\\/solinst-prod\\\/1\\\/H.21--NS\\\/0\",\"contentUrl\":\"https:\\\/\\\/solinst.d2.sc.omtrdc.net\\\/b\\\/ss\\\/solinst-prod\\\/1\\\/H.21--NS\\\/0\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/products\\\/groundwater-samplers\\\/410-peristaltic-pumps\\\/410-peristaltic-pump-instructions\\\/solinst-410-mk4-peristaltic-pump-operating-instructions\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/home\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Groundwater Samplers\",\"item\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/groundwater-samplers\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"410 Peristaltic Pumps\",\"item\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/groundwater-samplers\\\/410-peristaltic-pumps\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"410 Peristaltic Pump Instructions\",\"item\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/groundwater-samplers\\\/410-peristaltic-pumps\\\/410-peristaltic-pump-instructions\\\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"Solinst 410 Mk4 Peristaltic Pump Operating Instructions\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/#website\",\"url\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/\",\"name\":\"Solinst Groundwater and Surface Water Monitoring Instrumentation, Water Level Meters, Interface Meters, Dataloggers\",\"description\":\"High quality groundwater monitoring instruments and surface water monitoring instruments including water level meters, interface meters, groundwater samplers, dataloggers and more!\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-gb\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Solinst 410 MK4 Peristaltic Pump Operating Instructions","description":"Solinst Peristaltic Pump has an integral Forward\/Reverse, variable flow dial with an OFF position, providing flexibility during Peristaltic Pump Sampling operation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.solinst.com\/en-gb\/products\/groundwater-samplers\/410-peristaltic-pumps\/410-peristaltic-pump-instructions\/solinst-410-mk4-peristaltic-pump-operating-instructions\/","og_locale":"en_US","og_type":"article","og_title":"Solinst 410 Mk4 Peristaltic Pump Operating Instructions","og_description":"Find essential Peristaltic Pump Mk4 operating instructions to optimise your equipment's performance and ensure proper handling.","og_url":"https:\/\/www.solinst.com\/en-gb\/products\/groundwater-samplers\/410-peristaltic-pumps\/410-peristaltic-pump-instructions\/solinst-410-mk4-peristaltic-pump-operating-instructions\/","og_site_name":"Solinst Groundwater and Surface Water Monitoring Instrumentation, Water Level Meters, Interface Meters, Dataloggers","article_modified_time":"2026-05-07T21:01:52+00:00","og_image":[{"url":"https:\/\/solinst.d2.sc.omtrdc.net\/b\/ss\/solinst-prod\/1\/H.21--NS\/0","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"18 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.solinst.com\/en-gb\/products\/groundwater-samplers\/410-peristaltic-pumps\/410-peristaltic-pump-instructions\/solinst-410-mk4-peristaltic-pump-operating-instructions\/","url":"https:\/\/www.solinst.com\/en-gb\/products\/groundwater-samplers\/410-peristaltic-pumps\/410-peristaltic-pump-instructions\/solinst-410-mk4-peristaltic-pump-operating-instructions\/","name":"Solinst 410 MK4 Peristaltic Pump Operating Instructions","isPartOf":{"@id":"https:\/\/www.solinst.com\/en-gb\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solinst.com\/en-gb\/products\/groundwater-samplers\/410-peristaltic-pumps\/410-peristaltic-pump-instructions\/solinst-410-mk4-peristaltic-pump-operating-instructions\/#primaryimage"},"image":{"@id":"https:\/\/www.solinst.com\/en-gb\/products\/groundwater-samplers\/410-peristaltic-pumps\/410-peristaltic-pump-instructions\/solinst-410-mk4-peristaltic-pump-operating-instructions\/#primaryimage"},"thumbnailUrl":"https:\/\/solinst.d2.sc.omtrdc.net\/b\/ss\/solinst-prod\/1\/H.21--NS\/0","datePublished":"2025-12-31T02:57:39+00:00","dateModified":"2026-05-07T21:01:52+00:00","description":"Solinst Peristaltic Pump has an integral Forward\/Reverse, variable flow dial with an OFF position, providing flexibility during Peristaltic Pump Sampling operation.","breadcrumb":{"@id":"https:\/\/www.solinst.com\/en-gb\/products\/groundwater-samplers\/410-peristaltic-pumps\/410-peristaltic-pump-instructions\/solinst-410-mk4-peristaltic-pump-operating-instructions\/#breadcrumb"},"inLanguage":"en-gb","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solinst.com\/en-gb\/products\/groundwater-samplers\/410-peristaltic-pumps\/410-peristaltic-pump-instructions\/solinst-410-mk4-peristaltic-pump-operating-instructions\/"]}]},{"@type":"ImageObject","inLanguage":"en-gb","@id":"https:\/\/www.solinst.com\/en-gb\/products\/groundwater-samplers\/410-peristaltic-pumps\/410-peristaltic-pump-instructions\/solinst-410-mk4-peristaltic-pump-operating-instructions\/#primaryimage","url":"https:\/\/solinst.d2.sc.omtrdc.net\/b\/ss\/solinst-prod\/1\/H.21--NS\/0","contentUrl":"https:\/\/solinst.d2.sc.omtrdc.net\/b\/ss\/solinst-prod\/1\/H.21--NS\/0"},{"@type":"BreadcrumbList","@id":"https:\/\/www.solinst.com\/en-gb\/products\/groundwater-samplers\/410-peristaltic-pumps\/410-peristaltic-pump-instructions\/solinst-410-mk4-peristaltic-pump-operating-instructions\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.solinst.com\/en-gb\/home\/"},{"@type":"ListItem","position":2,"name":"Groundwater Samplers","item":"https:\/\/www.solinst.com\/en-gb\/groundwater-samplers\/"},{"@type":"ListItem","position":3,"name":"410 Peristaltic Pumps","item":"https:\/\/www.solinst.com\/en-gb\/groundwater-samplers\/410-peristaltic-pumps\/"},{"@type":"ListItem","position":4,"name":"410 Peristaltic Pump Instructions","item":"https:\/\/www.solinst.com\/en-gb\/groundwater-samplers\/410-peristaltic-pumps\/410-peristaltic-pump-instructions\/"},{"@type":"ListItem","position":5,"name":"Solinst 410 Mk4 Peristaltic Pump Operating Instructions"}]},{"@type":"WebSite","@id":"https:\/\/www.solinst.com\/en-gb\/#website","url":"https:\/\/www.solinst.com\/en-gb\/","name":"Solinst Groundwater and Surface Water Monitoring Instrumentation, Water Level Meters, Interface Meters, Dataloggers","description":"High quality groundwater monitoring instruments and surface water monitoring instruments including water level meters, interface meters, groundwater samplers, dataloggers and more!","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solinst.com\/en-gb\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-gb"}]}},"_links":{"self":[{"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/pages\/219711","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/comments?post=219711"}],"version-history":[{"count":3,"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/pages\/219711\/revisions"}],"predecessor-version":[{"id":219846,"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/pages\/219711\/revisions\/219846"}],"up":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/pages\/219685"}],"wp:attachment":[{"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/media?parent=219711"}],"wp:term":[{"taxonomy":"folder","embeddable":true,"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/folder?post=219711"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}