{"id":222484,"date":"2025-11-10T22:40:39","date_gmt":"2025-11-10T22:40:39","guid":{"rendered":"https:\/\/www.solinst.com\/battery-drawer-replacement\/"},"modified":"2026-05-07T22:34:30","modified_gmt":"2026-05-07T22:34:30","slug":"battery-drawer-replacement","status":"publish","type":"page","link":"https:\/\/www.solinst.com\/en-gb\/products\/level-measurement-devices\/101d-water-level-drawdown-meter\/101d-water-level-drawdown-meter-instructions\/battery-drawer-replacement\/","title":{"rendered":"Battery Drawer Replacement"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; admin_label=&#8221;H1 and breadcrumbs&#8221; _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;792ca5bd-0808-46bd-9ce7-3bcb8e74f4d3&#8243; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;4b28f470-0d73-4e9d-b92d-e6f41f2cea24&#8243; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.25.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_heading title=&#8221;Battery Drawer Replacement&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;6983e4e7-a6e0-4a8d-b486-49939fd240c0&#8243; hover_enabled=&#8221;0&#8243; sticky_enabled=&#8221;0&#8243;][\/et_pb_heading][dsm_breadcrumbs disabled_on=&#8221;on|off|off&#8221; _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; home_icon_text_color=&#8221;#d6d6d6&#8243; global_colors_info=&#8221;{}&#8221;][\/dsm_breadcrumbs][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;4759a92f-4b27-4854-bb2c-299854634e93&#8243; global_module=&#8221;121878&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; width=&#8221;90%&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_code admin_label=&#8221;101D Mobile Nav &#8211; Select Dropdown&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_css_free_form=&#8221;select {||||      font-size: 1em; \/* Adjust font size *\/||      padding: 10px;   \/* Optional: Increase padding for better spacing *\/||      width: 100%;||      box-sizing: border-box;\/* Optional: Adjust width to fit the container *\/||      height: 50px;||}||||    \/* Style for dropdown options (fallback if needed) *\/||select option {||      font-size: 1.2em; \/* Ensures option text matches select styling *\/||      width: 100%;||    }&#8221; global_colors_info=&#8221;{}&#8221;]<select name=\"dropdown\" onchange=\"location = this.value;\"><!-- [et_pb_line_break_holder] --><option value=\"\">101D Water Level DrawDown Meter Link Menu<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/level-measurement-devices\/101d-water-level-drawdown-meter\/\">Water Level DrawDown Meter Main Page<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/level-measurement-devices\/101-water-level-meter\/get-quote.php?prod=101d\">Get a Quote<\/option><!-- [et_pb_line_break_holder] -->  <!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/Forms\/sol.php\">Send Me Info<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/level-measurement-devices\/101d-water-level-drawdown-meter\/datasheet\/\">Datasheet<\/option><!-- [et_pb_line_break_holder] --><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/level-measurement-devices\/101d-water-level-drawdown-meter\/instructions\/\">Instructions<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/level-measurement-devices\/101d-water-level-drawdown-meter\/instructions\/101d-water-level-drawdown-meter-operating-instructions\/\">-Operating Instructions<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/level-measurement-devices\/101d-water-level-drawdown-meter\/instructions\/connecting-laser-marked-replacement-tape-to-reel\/\">-Connecting Laser Marked Replacement Tape to Reel<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/level-measurement-devices\/101d-water-level-drawdown-meter\/instructions\/probe-crimp-terminal-replacement\/\">-Probe Crimp Terminal Replacement<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/level-measurement-devices\/101d-water-level-drawdown-meter\/instructions\/backplate-replacement\/\">-Backplate Replacement<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/level-measurement-devices\/101d-water-level-drawdown-meter\/instructions\/battery-drawer-replacement\/\">-Battery Drawer Replacement<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/level-measurement-devices\/101-water-level-meter\/operating-instructions\/101-frame-break-probe-holder-replacement.pdf\">-Frame, Brake, and Probe Holder Replacement (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/level-measurement-devices\/101d-water-level-drawdown-meter\/instructions\/tape-seal-plug-brass-tube-replacement\/\">-Tape Seal Plug Brass Tubes Replacement<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/data\/wlm-comparison.pdf\">Meter Comparison Chart (PDF)<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/data\/wlm-tape-probe-comparison.pdf\">Tape &amp; Probe Comparison Chart (PDF)<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/instruments\/level-measurement-devices\/\">Level Measurement Devices<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/level-measurement-devices\/lmd-comparison.php\">Level Measurement Devices Comparison Chart<\/option><!-- [et_pb_line_break_holder] -->\t<!-- [et_pb_line_break_holder] --><option value=\"https:\/\/www.solinst.com\/products\/level-measurement-devices\/lmd-comparison-tape-probe.php\">Level Measurement Devices \u2013 Tape &amp; Probe Comparison<\/option><!-- [et_pb_line_break_holder] --><!-- [et_pb_line_break_holder] --><\/select>[\/et_pb_code][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; specialty=&#8221;on&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;5a5bca26-a9a5-4e6c-8fca-d64da3bdcd40&#8243; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;1_4&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_menu menu_id=&#8221;404&#8243; admin_label=&#8221;101D Water Level DrawDown Meter Main Nav&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;242faa89-ac4f-4e46-90fe-505e8c1eab79&#8243; global_module=&#8221;121778&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_menu][et_pb_slider disabled_on=&#8221;on|on|off&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; display_conditions=&#8221;W10=&#8221; link_option_url=&#8221;https:\/\/downloads.solinst.com\/free-shipping?utm_source=solinst&#038;utm_medium=WC-global-sidebar-position1&#038;utm_campaign=free-shipping&#8221; global_module=&#8221;53188&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_slide button_text=&#8221;Advantages of Using Water Flute&#8221; button_link=&#8221;https:\/\/www.solinst.com\/en-gb\/products\/solinst-flute\/405-water-flute\/?utm_source=solinst&amp;utm_medium=WC-global-sidebar-position1&amp;utm_campaign=405-water-flute&#8221; use_bg_overlay=&#8221;on&#8221; bg_overlay_color=&#8221;rgba(224,97,0,0.58)&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; background_color=&#8221;#F07C00&#8243; background_enable_color=&#8221;on&#8221; background_image=&#8221;https:\/\/www.solinst.com\/wp-content\/uploads\/2024\/12\/405-water-flute-multilevel-groundwater-system-installation.webp&#8221; background_enable_image=&#8221;on&#8221; background_position=&#8221;top_center&#8221; custom_button=&#8221;on&#8221; button_bg_color=&#8221;#f58025&#8243; button_border_width=&#8221;2px&#8221; button_border_radius=&#8221;20px&#8221; button_font=&#8221;|600|||||||&#8221; background_last_edited=&#8221;on|desktop&#8221; global_colors_info=&#8221;{}&#8221; sticky_transition=&#8221;on&#8221;]<\/p>\n<h2><strong><\/strong><\/h2>\n<h2><strong><\/strong><\/h2>\n<h2><strong><\/strong><\/h2>\n<p>&nbsp;<\/p>\n<h2>Depth Discrete Groundwater Monitoring<\/h2>\n<p><b>Reduce Costs and Field Time<\/b><\/p>\n<p>[\/et_pb_slide][\/et_pb_slider][et_pb_slider disabled_on=&#8221;on|off|off&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; link_option_url=&#8221;https:\/\/www.solinst.com\/instruments\/groundwater-samplers\/410-peristaltic-pumps\/?utm_source=solinst&#038;utm_medium=WC-global-sidebar-position2&#038;utm_campaign=410-101d&#8221; global_module=&#8221;53561&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_slide heading=&#8221;Automated Pumping with DrawDown Mode&#8221; button_text=&#8221;New Peristaltic Pump Mk5&#8243; button_link=&#8221;https:\/\/www.solinst.com\/instruments\/groundwater-samplers\/410-peristaltic-pumps\/?utm_source=solinst&amp;utm_medium=WC-global-sidebar-position2&amp;utm_campaign=410-101d&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; header_text_color=&#8221;#000000&#8243; background_color=&#8221;RGBA(255,255,255,0)&#8221; background_enable_color=&#8221;on&#8221; background_image=&#8221;https:\/\/www.solinst.com\/wp-content\/uploads\/2026\/01\/101d-water-level-drawdown-meter-2-965&#215;500-1.webp&#8221; background_enable_image=&#8221;on&#8221; background_size=&#8221;contain&#8221; custom_button=&#8221;on&#8221; button_bg_color=&#8221;#f58025&#8243; button_border_width=&#8221;2px&#8221; button_border_radius=&#8221;20px&#8221; button_font=&#8221;|600|||||||&#8221; button_custom_margin=&#8221;||||false|false&#8221; button_custom_padding=&#8221;1px||||false|false&#8221; custom_padding=&#8221;76px||||false|false&#8221; header_text_shadow_style=&#8221;preset3&#8243; global_colors_info=&#8221;{}&#8221; sticky_transition=&#8221;on&#8221;]<\/p>\n<h2\/>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>[\/et_pb_slide][\/et_pb_slider][\/et_pb_column][et_pb_column type=&#8221;3_4&#8243; specialty_columns=&#8221;3&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_row_inner _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;3d68e16c-1ed2-447f-b17f-a63c20af3cf6&#8243; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner saved_specialty_column_type=&#8221;3_4&#8243; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][dsm_icon_list icon_font_size=&#8221;30px&#8221; list_alignment=&#8221;flex-end&#8221; text_indent=&#8221;10px&#8221; list_alignment_tablet=&#8221;flex-end&#8221; list_alignment_phone=&#8221;flex-start&#8221; list_alignment_last_edited=&#8221;on|desktop&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;|600|||||||&#8221; link_option_url_new_window=&#8221;on&#8221; global_colors_info=&#8221;{}&#8221;][dsm_icon_list_child text=&#8221;Battery Drawer Replacement PDF&#8221; font_icon=&#8221;&#xf1c1;||fa||900&#8243; icon_color=&#8221;#ff8500&#8243; url=&#8221;https:\/\/www.solinst.com\/products\/level-measurement-devices\/101-water-level-meter\/operating-instructions\/battery-drawer-replacement-106974\/battery-drawer-replacement.pdf&#8221; url_new_window=&#8221;on&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; icon_color__hover_enabled=&#8221;on|hover&#8221; icon_color__hover=&#8221;#828282&#8243; text_text_color__hover_enabled=&#8221;on|hover&#8221; text_text_color__hover=&#8221;#7a7a7a&#8221;][\/dsm_icon_list_child][\/dsm_icon_list][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner column_structure=&#8221;1_2,1_2&#8243; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;3676f7e6-7b83-4698-94ce-2cc9fa9ae43d&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner type=&#8221;1_2&#8243; saved_specialty_column_type=&#8221;3_4&#8243; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_heading title=&#8221;Tools and Materials Needed&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;46ad5c23-ecb8-466b-9973-452975f03683&#8243; hover_enabled=&#8221;0&#8243; sticky_enabled=&#8221;0&#8243;][\/et_pb_heading][et_pb_text admin_label=&#8221;research article&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; header_font_size=&#8221;26px&#8221; header_2_font_size=&#8221;22px&#8221; hover_enabled=&#8221;0&#8243; global_colors_info=&#8221;{}&#8221; sticky_enabled=&#8221;0&#8243;]<\/p>\n<ol>\n<li>Replacement Battery Drawer Assembly (#103559), includes:\n<ul>\n<li>Single 9 Volt Battery Tray\/Drawer (#103308)<\/li>\n<li>2 x #4 x 1\/2&#8243; Phillips Screws (#101712) for plastic reels<\/li>\n<li>2 x #4-40 x 1\/2&#8243; Phillips Bolts (#100103)<br \/>\nand 2 x #4-40 Nuts #102154) for metal reels<\/li>\n<\/ul>\n<\/li>\n<li>Phillips Screwdriver<\/li>\n<li>#4-40 Spanner (for metal reels)<\/li>\n<li>Wire Cutters and Strippers (if required)<\/li>\n<li>Soldering Wire and Iron (if required)<\/li>\n<\/ol>\n<p>[\/et_pb_text][\/et_pb_column_inner][et_pb_column_inner type=&#8221;1_2&#8243; saved_specialty_column_type=&#8221;3_4&#8243; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text admin_label=&#8221;research article&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; header_font_size=&#8221;26px&#8221; header_2_font_size=&#8221;22px&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2><img decoding=\"async\" src=\"\/products\/level-measurement-devices\/101-water-level-meter\/images\/operating-instructions\/battery-drawer.jpg\" alt=\"solinst meters battery drawer\" width=\"500\" title=\"Solinst Meters Battery Drawer\"><\/h2>\n<p>[\/et_pb_text][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner column_structure=&#8221;1_2,1_2&#8243; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;3676f7e6-7b83-4698-94ce-2cc9fa9ae43d&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner type=&#8221;1_2&#8243; saved_specialty_column_type=&#8221;3_4&#8243; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_heading title=&#8221;Instructions&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;46ad5c23-ecb8-466b-9973-452975f03683&#8243; hover_enabled=&#8221;0&#8243; sticky_enabled=&#8221;0&#8243;][\/et_pb_heading][et_pb_text admin_label=&#8221;research article&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; header_font_size=&#8221;26px&#8221; header_2_font_size=&#8221;22px&#8221; hover_enabled=&#8221;0&#8243; global_colors_info=&#8221;{}&#8221; sticky_enabled=&#8221;0&#8243;]1. Remove the battery drawer from the faceplate.[\/et_pb_text][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;e910b435-fe18-45d2-b351-bda808b1a267&#8243; hover_enabled=&#8221;0&#8243; global_colors_info=&#8221;{}&#8221; sticky_enabled=&#8221;0&#8243;]<\/p>\n<div class=\"boxColumn\">\n<div class=\"boxContent\">\n<h3><strong>Note:  <\/strong><\/h3>\n<p>To remove the battery drawer, press the drawer in, lift, then pull. The battery drawer should slide out of the faceplate enough to allow it to be pulled out and removed. <\/p>\n<\/div>\n<\/div>\n<p>[\/et_pb_text][et_pb_text admin_label=&#8221;research article&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; header_font_size=&#8221;26px&#8221; header_2_font_size=&#8221;22px&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p>2. Undo the three screws from the front of the faceplate and remove the faceplate from the reel.<\/p>\n<p>3. For Meters with a Molex connection, undo the connector that links the faceplate electronics to the tape.<\/p>\n<p>4. For Meters with the tape leads connected to the circuit board, press down on the white terminals of the push-release fittings and pull to remove the tape\/cable leads. <strong>Note how they are connected<\/strong>.<\/p>\n<p>5. For the Meters with a Molex connection, cut the red and black wires from the back of the battery tray close to the terminals.<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;e910b435-fe18-45d2-b351-bda808b1a267&#8243; global_colors_info=&#8221;{}&#8221;]<\/p>\n<div class=\"boxColumn\">\n<div class=\"boxContent\">\n<h3><strong>Note:  <\/strong><\/h3>\n<p>Model 122 P8 Interface Meters have two black wires connected to the battery tray.<\/p>\n<\/div>\n<\/div>\n<p>[\/et_pb_text][\/et_pb_column_inner][et_pb_column_inner type=&#8221;1_2&#8243; saved_specialty_column_type=&#8221;3_4&#8243; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text admin_label=&#8221;research article&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; header_font_size=&#8221;26px&#8221; header_2_font_size=&#8221;22px&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p>6. For the Meters where tape leads were connected to the circuit board, simply pull to remove the red and black wires from the terminals on the battery tray.<\/p>\n<p>7. Undo the two screws (and nuts for metal reels) holding the battery tray in the faceplate. Remove the old battery tray. <\/p>\n<p>8. Place the new battery tray through the faceplate and secure it with the two screws (and nuts where required).<\/p>\n<p>9. For the Meters with a Molex connection, strip the red and black wires, cut from the old battery tray, by approximately 1\/4&#8243; (6 mm). Solder the black wire(s) to the negative terminal on the battery tray, and the red wire to the positive terminal. The terminals are labelled on the tray.  <\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;e910b435-fe18-45d2-b351-bda808b1a267&#8243; global_colors_info=&#8221;{}&#8221;]<\/p>\n<div class=\"boxColumn\">\n<div class=\"boxContent\">\n<h3><strong>Note:  <\/strong><\/h3>\n<p>For Model 122 P8 Interface Meters, solder the black wire with brown resistor to the positive terminal on the battery tray.<\/p>\n<\/div>\n<\/div>\n<p>[\/et_pb_text][et_pb_text admin_label=&#8221;research article&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; header_font_size=&#8221;26px&#8221; header_2_font_size=&#8221;22px&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p>10. For the Meters where tape leads were connected to the circuit board, use the quick-connect fittings on the red and black wires to connect the black wire to the negative terminal on the battery tray, and the red wire to the positive terminal. The terminals are labelled on the tray. <\/p>\n<p>11. Note the polarity and place the battery in the new battery drawer. The positive terminal of the battery is placed towards the small notch in the end of the drawer. <\/p>\n<p>12. Slide the battery drawer into the battery tray in the faceplate.<\/p>\n<p>13. If applicable, reconnect the Molex connector from the faceplate electronics to the tape.<\/p>\n<p>14. If applicable, press down on the white terminals on the circuit board and insert the tape\/cable leads. Release the terminals and the leads should be secured. <\/p>\n<p>For the Mk3 107 and 201, the lead on the top of the tape is inserted into the terminal labelled TOP on the circuit board.<\/p>\n<p>For the Mk2 101, 101D, and 105, the lead on the top of the tape (top of numbers or see note below) is inserted into the terminal with a white square below it on the circuit board.<\/p>\n<p>&nbsp;<\/p>\n<p>[\/et_pb_text][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;3676f7e6-7b83-4698-94ce-2cc9fa9ae43d&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner saved_specialty_column_type=&#8221;3_4&#8243; _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;e910b435-fe18-45d2-b351-bda808b1a267&#8243; global_colors_info=&#8221;{}&#8221;]<\/p>\n<div class=\"boxColumn\">\n<div class=\"boxContent\">\n<h3><strong>Note:  <\/strong><\/h3>\n<p>There is a &#8220;P&#8221; etched on the tape to help denote the proper orientation of the tape \u2013 top and bottom leads.<\/p>\n<p><img decoding=\"async\" src=\"\/products\/level-measurement-devices\/101-water-level-meter\/operating-instructions\/101-button-replacement-113769\/images\/101-p-etched-1x.jpg\" alt=\"there is a \"p\" etched on the tape to help denote the proper orientation of the tape \u2013 top and bottom leads\" width=\"500\" title=\"There is a \"P\" etched on the tape to help denote the proper orientation of the tape \u2013 top and bottom leads.\"><\/p>\n<\/div>\n<\/div>\n<p>[\/et_pb_text][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;3676f7e6-7b83-4698-94ce-2cc9fa9ae43d&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner saved_specialty_column_type=&#8221;3_4&#8243; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text admin_label=&#8221;research article&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; header_font_size=&#8221;26px&#8221; header_2_font_size=&#8221;22px&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p>For the Model Mk2 102, the negative lead is inserted into the terminal with a white square below it on the circuit board. The negative pin is connected to the black insulated braided wire. <\/p>\n<p>15. Test that the Meter is working correctly. Refer to the Operating Instructions, if required. <\/p>\n<p>16. Use the three screws to replace the faceplate back on the reel.<\/p>\n<p>&nbsp;<\/p>\n<p>[\/et_pb_text][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;3676f7e6-7b83-4698-94ce-2cc9fa9ae43d&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner saved_specialty_column_type=&#8221;3_4&#8243; _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_heading title=&#8221;Related Products&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;46ad5c23-ecb8-466b-9973-452975f03683&#8243; hover_enabled=&#8221;0&#8243; global_colors_info=&#8221;{}&#8221; sticky_enabled=&#8221;0&#8243;][\/et_pb_heading][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner column_structure=&#8221;1_2,1_2&#8243; disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; border_width_bottom=&#8221;1px&#8221; border_color_bottom=&#8221;#d3d3d3&#8243; global_module=&#8221;120903&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner type=&#8221;1_2&#8243; _builder_version=&#8221;4.25.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_image src=&#8221;https:\/\/www.solinst.com\/wp-content\/uploads\/2025\/09\/407-bladder-pumps.webp&#8221; alt=&#8221;solinst model 407 bladder pumps&#8221; title_text=&#8221;Solinst Model 407 Bladder Pumps&#8221; url=&#8221;https:\/\/www.solinst.com\/products\/groundwater-samplers\/407-bladder-pumps\/index.php&#8221; align=&#8221;center&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; border_color_all=&#8221;#bcbcbc&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][\/et_pb_column_inner][et_pb_column_inner type=&#8221;1_2&#8243; _builder_version=&#8221;4.25.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; header_2_line_height=&#8221;1.3em&#8221; custom_margin=&#8221;60px||||false|false&#8221; custom_margin_tablet=&#8221;0px||||false|false&#8221; custom_margin_phone=&#8221;0px||||false|false&#8221; custom_margin_last_edited=&#8221;on|desktop&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2><strong>Bladder Pumps with Easy to Replace Bladder Cartridges<\/strong><\/h2>\n<p><a href=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/407-bladder-pumps\/index.php\" title=\"Solinst Bladder Pumps\"><strong>Solinst Bladder Pumps<\/strong><\/a> now feature Santoprene\u00ae bladder cartridges that are quick and easy to replace in the field \u2013 no tools required. PVC Bladder Pumps are low cost and excellent for metals sampling and in harsh, corrosive environments. <\/p>\n<p>[\/et_pb_text][et_pb_button button_url=&#8221;https:\/\/www.solinst.com\/products\/groundwater-samplers\/407-bladder-pumps\/index.php&#8221; button_text=&#8221;Low Flow Groundwater Sampling&#8221; button_alignment=&#8221;right&#8221; button_alignment_tablet=&#8221;center&#8221; button_alignment_phone=&#8221;center&#8221; button_alignment_last_edited=&#8221;on|phone&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_button=&#8221;on&#8221; button_text_size=&#8221;20px&#8221; button_text_color=&#8221;#000000&#8243; button_bg_color=&#8221;#FFFFFF&#8221; button_border_color=&#8221;#ff8500&#8243; button_border_radius=&#8221;20px&#8221; button_icon=&#8221;&#x3d;||divi||400&#8243; custom_padding=&#8221;0px|||||&#8221; button_text_size_tablet=&#8221;18px&#8221; button_text_size_phone=&#8221;16px&#8221; button_text_size_last_edited=&#8221;on|desktop&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner column_structure=&#8221;1_2,1_2&#8243; disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; border_width_bottom=&#8221;1px&#8221; border_color_bottom=&#8221;#d3d3d3&#8243; global_module=&#8221;120904&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner type=&#8221;1_2&#8243; _builder_version=&#8221;4.25.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_image src=&#8221;https:\/\/www.solinst.com\/wp-content\/uploads\/2025\/09\/101d-water-level-drawdown-meter-and-power-winder.webp&#8221; alt=&#8221;101d water level drawdown meter with power winder installed&#8221; title_text=&#8221;101D Water Level DrawDown Meter with Power Winder Installed&#8221; url=&#8221;https:\/\/www.solinst.com\/products\/level-measurement-devices\/101-power-winder\/101-power-winder.php&#8221; align=&#8221;center&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; border_color_all=&#8221;#bcbcbc&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][\/et_pb_column_inner][et_pb_column_inner type=&#8221;1_2&#8243; _builder_version=&#8221;4.25.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; header_2_line_height=&#8221;1.3em&#8221; custom_margin=&#8221;60px||||false|false&#8221; custom_margin_tablet=&#8221;0px||||false|false&#8221; custom_margin_phone=&#8221;0px||||false|false&#8221; custom_margin_last_edited=&#8221;on|desktop&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2><strong>101 Power Winder<\/strong><\/h2>\n<p>The <a href=\"https:\/\/www.solinst.com\/products\/level-measurement-devices\/101-power-winder\/101-power-winder.php\" title=\"101 Power Winder\"><strong>101 Power Winder<\/strong><\/a> provides both convenience and ease of use for all Solinst reel-mounted devices. It is lightweight and easy to attach to small, medium or large size Solinst reels, and is simple to adjust to fit other reels in the market. Effortlessly wind longer tape lengths.  <\/p>\n<p>(Image shows 101 Power Winder Installed on Solinst Model 101D Water Level DrawDown Meter)<\/p>\n<p>[\/et_pb_text][et_pb_button button_url=&#8221;https:\/\/www.solinst.com\/products\/level-measurement-devices\/101-power-winder\/101-power-winder.php&#8221; button_text=&#8221;Effortlessly Wind Longer Tape Lengths&#8221; button_alignment=&#8221;right&#8221; button_alignment_tablet=&#8221;center&#8221; button_alignment_phone=&#8221;center&#8221; button_alignment_last_edited=&#8221;on|phone&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_button=&#8221;on&#8221; button_text_size=&#8221;20px&#8221; button_text_color=&#8221;#000000&#8243; button_bg_color=&#8221;#FFFFFF&#8221; button_border_color=&#8221;#ff8500&#8243; button_border_radius=&#8221;20px&#8221; button_icon=&#8221;&#x3d;||divi||400&#8243; custom_padding=&#8221;0px|||||&#8221; button_text_size_tablet=&#8221;18px&#8221; button_text_size_phone=&#8221;16px&#8221; button_text_size_last_edited=&#8221;on|desktop&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner column_structure=&#8221;1_2,1_2&#8243; disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; border_width_bottom=&#8221;1px&#8221; border_color_bottom=&#8221;#d3d3d3&#8243; global_module=&#8221;120905&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner type=&#8221;1_2&#8243; _builder_version=&#8221;4.25.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_image src=&#8221;https:\/\/www.solinst.com\/wp-content\/uploads\/2025\/09\/615ml-multilevel-drive-point-piezometer.webp&#8221; alt=&#8221;615ml multilevel drive point piezometers&#8221; title_text=&#8221;615ML Multilevel Drive Point Piezometers&#8221; url=&#8221;https:\/\/www.solinst.com\/products\/direct-push-equipment\/615-drive-point-piezometers\/index.php&#8221; align=&#8221;center&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; border_color_all=&#8221;#bcbcbc&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][\/et_pb_column_inner][et_pb_column_inner type=&#8221;1_2&#8243; _builder_version=&#8221;4.25.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; header_2_line_height=&#8221;1.3em&#8221; custom_margin=&#8221;60px||||false|false&#8221; custom_margin_tablet=&#8221;0px||||false|false&#8221; custom_margin_phone=&#8221;0px||||false|false&#8221; custom_margin_last_edited=&#8221;on|desktop&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2><strong>Multilevel Drive Point Piezometers<\/strong><\/h2>\n<p>The <a href=\"https:\/\/www.solinst.com\/products\/direct-push-equipment\/615-drive-point-piezometers\/index.php\" title=\"615ML Multilevel Drive-Point System\"><strong>615ML Multilevel Drive-Point System<\/strong><\/a> allows monitoring of up to 6 zones in one drive, using ports with a dual barb stem to attach either \u00bc&#8221; or \u215c&#8221; OD tubing. Install using extensions and a Manual Slide Hammer, similar to standard 615 installations, for high-resolution vertical groundwater or soil gas profiling. <\/p>\n<p>[\/et_pb_text][et_pb_button button_url=&#8221;https:\/\/www.solinst.com\/products\/direct-push-equipment\/615-drive-point-piezometers\/index.php&#8221; button_text=&#8221;Monitor Up To 6 Zones At the Same Time&#8221; button_alignment=&#8221;right&#8221; button_alignment_tablet=&#8221;center&#8221; button_alignment_phone=&#8221;center&#8221; button_alignment_last_edited=&#8221;on|phone&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_button=&#8221;on&#8221; button_text_size=&#8221;20px&#8221; button_text_color=&#8221;#000000&#8243; button_bg_color=&#8221;#FFFFFF&#8221; button_border_color=&#8221;#ff8500&#8243; button_border_radius=&#8221;20px&#8221; button_icon=&#8221;&#x3d;||divi||400&#8243; custom_padding=&#8221;0px|||||&#8221; button_text_size_tablet=&#8221;18px&#8221; button_text_size_phone=&#8221;16px&#8221; button_text_size_last_edited=&#8221;on|desktop&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner column_structure=&#8221;1_2,1_2&#8243; disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; border_width_bottom=&#8221;1px&#8221; border_color_bottom=&#8221;#d3d3d3&#8243; global_module=&#8221;120906&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner type=&#8221;1_2&#8243; _builder_version=&#8221;4.25.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_image src=&#8221;https:\/\/www.solinst.com\/wp-content\/uploads\/2025\/09\/104-sonic-water-level-meter.webp&#8221; alt=&#8221;solinst model 104 sonic water level meter&#8221; title_text=&#8221;Solinst Model 104 Sonic Water Level Meter&#8221; url=&#8221;https:\/\/www.solinst.com\/products\/level-measurement-devices\/104-sonic-water-level-meter\/104.php&#8221; align=&#8221;center&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; border_color_all=&#8221;#bcbcbc&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][\/et_pb_column_inner][et_pb_column_inner type=&#8221;1_2&#8243; _builder_version=&#8221;4.25.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; header_2_line_height=&#8221;1.3em&#8221; custom_margin=&#8221;60px||||false|false&#8221; custom_margin_tablet=&#8221;0px||||false|false&#8221; custom_margin_phone=&#8221;0px||||false|false&#8221; custom_margin_last_edited=&#8221;on|desktop&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2><strong>Measure Water Levels <br \/>Without Lowering Equipment Down the Well<\/strong><\/h2>\n<p>The <a href=\"https:\/\/www.solinst.com\/products\/level-measurement-devices\/104-sonic-water-level-meter\/104.php\" title=\"104 Solinst Sonic Water Level Meter\"><strong>104 Solinst Sonic Water Level Meter<\/strong><\/a> is a portable, acoustic ranging instrument designed to simply and quickly provide depth to static water level measurements down to 600 m (2000 ft), without the need to lower equipment down a well. Ideal for straight, crooked, narrow, hard to access, or contaminated wells. <\/p>\n<p>[\/et_pb_text][et_pb_button button_url=&#8221;https:\/\/www.solinst.com\/products\/level-measurement-devices\/104-sonic-water-level-meter\/104.php&#8221; button_text=&#8221;No Contact Sonic Water Level Meters&#8221; button_alignment=&#8221;right&#8221; button_alignment_tablet=&#8221;center&#8221; button_alignment_phone=&#8221;center&#8221; button_alignment_last_edited=&#8221;on|phone&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_button=&#8221;on&#8221; button_text_size=&#8221;20px&#8221; button_text_color=&#8221;#000000&#8243; button_bg_color=&#8221;#FFFFFF&#8221; button_border_color=&#8221;#ff8500&#8243; button_border_radius=&#8221;20px&#8221; button_icon=&#8221;&#x3d;||divi||400&#8243; custom_padding=&#8221;0px|||||&#8221; button_text_size_tablet=&#8221;18px&#8221; button_text_size_phone=&#8221;16px&#8221; button_text_size_last_edited=&#8221;on|desktop&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;3676f7e6-7b83-4698-94ce-2cc9fa9ae43d&#8221; custom_margin=&#8221;50px||3em||false|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner saved_specialty_column_type=&#8221;3_4&#8243; _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_heading title=&#8221;Related Blog Posts&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; title_level=&#8221;h2&#8243; title_font=&#8221;|700|||||||&#8221; title_font_size=&#8221;22px&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_heading][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner column_structure=&#8221;1_2,1_2&#8243; disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; border_width_bottom=&#8221;1px&#8221; border_color_bottom=&#8221;#d3d3d3&#8243; global_module=&#8221;120907&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column_inner type=&#8221;1_2&#8243; _builder_version=&#8221;4.25.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_image src=&#8221;https:\/\/www.solinst.com\/wp-content\/uploads\/2025\/09\/importance-of-measuring-water-level-drawdown.webp&#8221; alt=&#8221;importance of measuring water level drawdown&#8221; title_text=&#8221;Importance of Measuring Water Level DrawDown&#8221; url=&#8221;https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/the-importance-of-measuring-drawdown\/&#8221; align=&#8221;center&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; border_color_all=&#8221;#bcbcbc&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][\/et_pb_column_inner][et_pb_column_inner type=&#8221;1_2&#8243; _builder_version=&#8221;4.25.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; header_2_line_height=&#8221;1.3em&#8221; custom_margin=&#8221;60px||||false|false&#8221; custom_margin_tablet=&#8221;0px||||false|false&#8221; custom_margin_phone=&#8221;0px||||false|false&#8221; custom_margin_last_edited=&#8221;on|desktop&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2><strong>The Importance of Measuring Water Level Drawdown<\/strong><\/h2>\n<p>How Using a <strong>Levelogger<\/strong> and <strong>101D Water Level DrawDown<\/strong> <strong>Meter<\/strong> Together Provides Essential Data.<br \/>What is Drawdown? Drawdown is a change in groundwater level due to an applied stress, caused by events such as: Pumping from a well Pumping from a neighbouring well Intensive water taking from local area Seasonal declines as recharge rates lower&#8230;. <\/p>\n<p>[\/et_pb_text][et_pb_button button_url=&#8221;https:\/\/www.solinst.com\/products\/level-measurement-devices\/101d-water-level-drawdown-meter\/101d.php&#8221; button_text=&#8221;How is Drawdown Measured?&#8221; button_alignment=&#8221;right&#8221; button_alignment_tablet=&#8221;center&#8221; button_alignment_phone=&#8221;center&#8221; button_alignment_last_edited=&#8221;on|phone&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_button=&#8221;on&#8221; button_text_size=&#8221;20px&#8221; button_text_color=&#8221;#000000&#8243; button_bg_color=&#8221;#FFFFFF&#8221; button_border_color=&#8221;#ff8500&#8243; button_border_radius=&#8221;20px&#8221; button_icon=&#8221;&#x3d;||divi||400&#8243; custom_padding=&#8221;0px|||||&#8221; button_text_size_tablet=&#8221;18px&#8221; button_text_size_phone=&#8221;16px&#8221; button_text_size_last_edited=&#8221;on|desktop&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][\/et_pb_column][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; admin_label=&#8221;Adobe Analytics Code&#8221; _builder_version=&#8221;4.27.0&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;||4px|||&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.27.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_code admin_label=&#8221;AA Code for this page&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]<!-- SiteCatalyst code version: H.21. Copyright 1996-2010 Adobe, Inc. All Rights Reserved More info available at http:\/\/www.omniture.com --><!-- [et_pb_line_break_holder] --><script language=\"JavaScript\" type=\"text\/javascript\" src=\"\/\/www.solinst.com\/s_code.js\"><\/script><!-- [et_pb_line_break_holder] --><script language=\"JavaScript\" type=\"text\/javascript\"><!--<!-- [et_pb_line_break_holder] -->s.pageName=\"101d battery drawer replacement instructions\"<!-- [et_pb_line_break_holder] -->s.server=\"\"<!-- [et_pb_line_break_holder] -->s.channel=\"products\"<!-- [et_pb_line_break_holder] -->s.pageType=\"\"<!-- [et_pb_line_break_holder] -->s.prop1=\"level measurement devices\"<!-- [et_pb_line_break_holder] -->s.prop2=\"101d\"<!-- [et_pb_line_break_holder] -->s.prop3=\"101d instructions\"<!-- [et_pb_line_break_holder] -->s.prop4=\"101d battery drawer replacement instructions\"<!-- [et_pb_line_break_holder] -->s.prop5=\"\"<!-- [et_pb_line_break_holder] -->s.prop6=\"\"<!-- [et_pb_line_break_holder] -->s.prop7=\"\"<!-- [et_pb_line_break_holder] -->s.prop8=\"\"<!-- [et_pb_line_break_holder] -->s.prop9=\"\"<!-- [et_pb_line_break_holder] -->s.prop10=\"\"<!-- [et_pb_line_break_holder] -->s.prop11=\"\"<!-- [et_pb_line_break_holder] -->s.prop12=\"\"<!-- [et_pb_line_break_holder] -->s.prop13=\"\"<!-- [et_pb_line_break_holder] -->s.prop14=\"\"<!-- [et_pb_line_break_holder] -->s.prop15=\"\"<!-- [et_pb_line_break_holder] -->s.prop16=\"\"<!-- [et_pb_line_break_holder] -->s.prop17=\"\"<!-- [et_pb_line_break_holder] -->s.prop18=\"\"<!-- [et_pb_line_break_holder] -->s.prop19=\"\"<!-- [et_pb_line_break_holder] -->s.prop20=\"\"<!-- [et_pb_line_break_holder] -->s.prop21=\"\"<!-- [et_pb_line_break_holder] -->s.prop22=\"\"<!-- [et_pb_line_break_holder] -->s.prop23=\"\"<!-- [et_pb_line_break_holder] -->s.prop24=\"\"<!-- [et_pb_line_break_holder] -->s.prop25=\"\"<!-- [et_pb_line_break_holder] -->s.prop26=\"\"<!-- [et_pb_line_break_holder] -->s.prop27=\"\"<!-- [et_pb_line_break_holder] -->s.prop28=\"\"<!-- [et_pb_line_break_holder] -->s.prop29=\"\"<!-- [et_pb_line_break_holder] -->s.prop30=\"\"<!-- [et_pb_line_break_holder] -->s.prop31=\"\"<!-- [et_pb_line_break_holder] -->s.prop32=\"\"<!-- [et_pb_line_break_holder] -->s.prop33=\"\"<!-- [et_pb_line_break_holder] -->s.hier1=\"solinst:products:level measurement devices:101d:101d instructions:101d battery drawer replacement instructions\"<!-- [et_pb_line_break_holder] --><!-- [et_pb_line_break_holder] -->\/* Conversion Variables *\/<!-- [et_pb_line_break_holder] -->s.campaign=\"\"<!-- [et_pb_line_break_holder] -->s.events=\"\"<!-- [et_pb_line_break_holder] -->s.eVar1=\"\"<!-- [et_pb_line_break_holder] -->s.eVar2=\"\"<!-- [et_pb_line_break_holder] -->s.eVar3=\"\"<!-- [et_pb_line_break_holder] -->s.eVar4=\"\"<!-- [et_pb_line_break_holder] -->s.eVar5=\"\"<!-- [et_pb_line_break_holder] -->s.eVar6=\"\"<!-- [et_pb_line_break_holder] -->s.eVar7=\"\"<!-- [et_pb_line_break_holder] -->s.eVar8=\"\"<!-- [et_pb_line_break_holder] -->s.eVar9=\"\"<!-- [et_pb_line_break_holder] -->s.eVar10=\"\"<!-- [et_pb_line_break_holder] -->s.eVar11=\"\"<!-- [et_pb_line_break_holder] -->s.eVar12=\"\"<!-- [et_pb_line_break_holder] -->s.eVar13=\"\"<!-- [et_pb_line_break_holder] -->s.eVar14=\"\"<!-- [et_pb_line_break_holder] -->s.eVar15=\"\"<!-- [et_pb_line_break_holder] -->s.eVar16=\"\"<!-- [et_pb_line_break_holder] -->s.eVar17=\"\"<!-- [et_pb_line_break_holder] -->s.state=\"\"<!-- [et_pb_line_break_holder] -->s.zip=\"\"<!-- [et_pb_line_break_holder] -->\/************* DO NOT ALTER ANYTHING BELOW THIS LINE ! **************\/<!-- [et_pb_line_break_holder] -->var s_code=s.t();if(s_code)document.write(s_code)\/\/--><\/script><!-- [et_pb_line_break_holder] --><script language=\"JavaScript\" type=\"text\/javascript\"><!--<!-- [et_pb_line_break_holder] -->if(navigator.appVersion.indexOf('MSIE')>=0)document.write(unescape('%3C')+'!-'+'-')<!-- [et_pb_line_break_holder] -->\/\/--><\/script><!-- [et_pb_line_break_holder] --><noscript><!-- [et_pb_line_break_holder] -->  <a href=\"https:\/\/www.omniture.com\" title=\"Web Analytics\"><!-- [et_pb_line_break_holder] -->    <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/solinst.d2.sc.omtrdc.net\/b\/ss\/solinst-prod\/1\/H.21--NS\/0\" height=\"1\" width=\"1\" border=\"0\" alt=\"\"><!-- [et_pb_line_break_holder] -->  <\/a><!-- [et_pb_line_break_holder] --><\/noscript><!-- [et_pb_line_break_holder] --><!--\/DO NOT REMOVE\/--><!-- [et_pb_line_break_holder] --><!-- End SiteCatalyst code version: H.21. -->[\/et_pb_code][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p><div class=\"et_pb_module dsm_breadcrumbs dsm_breadcrumbs_0\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module_inner\">\n\t\t\t\t\t<nav class=\"dsm_breadcrumbs_wrap\">\n\t\t\t\t<ul class=\"dsm_breadcrumbs\" itemscope itemtype=\"https:\/\/schema.org\/BreadcrumbList\">\t\t\t<li class=\"dsm_breadcrumbs_item dsm_home_item dsm_home_item_custom\" itemprop=\"itemListElement\" itemscope\n\t\t\titemtype=\"https:\/\/schema.org\/ListItem\">\n\t\t\t\t<a href=\"https:\/\/www.solinst.com\/en-gb\/\" itemprop=\"item\" target=\"\">\n\t\t\t\t\t<span class='dsm_home_text_wrapper'>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"et-pb-icon dsm_home_icon\">\ue009<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"dsm_home_text\" itemprop=\"name\">\n\t\t\t\t\t\t\t\tHome\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t<\/a>\n\t\t\t\t<meta itemprop=\"position\" content=\"1\" \/>\n\t\t\t<\/li>\n\n\t\t<li class=\"dsm_breadcrumbs_separator\"> <span class=\"et-pb-icon dsm_separator_icon\">5<\/span><\/li><\/ul>\n\t\t\t<\/nav>\n\t\t\t\t<\/div>\n\t\t\t<\/div> &nbsp; Depth Discrete Groundwater Monitoring Reduce Costs and Field Time &nbsp; &nbsp; &nbsp;<div class=\"et_pb_module dsm_icon_list dsm_icon_list_0\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module_inner\">\n\t\t\t\t\t<ul class=\"dsm_icon_list_items dsm_icon_list_ltr_direction dsm_icon_list_layout_vertical\"><li class=\"dsm_icon_list_child dsm_icon_list_child_0\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<a href=\"https:\/\/www.solinst.com\/products\/level-measurement-devices\/101-water-level-meter\/operating-instructions\/battery-drawer-replacement-106974\/battery-drawer-replacement.pdf\" target=\"_blank\"><span class=\"dsm_icon_list_wrapper\"><span class=\"dsm_icon_list_icon\">\uf1c1<\/span><\/span><span class=\"dsm_icon_list_text\">Battery Drawer Replacement PDF<\/span><\/a>\n\t\t\t<\/li><\/ul>\n\t\t\t\t<\/div>\n\t\t\t<\/div> Replacement Battery Drawer Assembly (#103559), includes: Single 9 Volt Battery Tray\/Drawer (#103308) 2 x #4 x 1\/2&#8243; Phillips Screws (#101712) for plastic reels 2 x #4-40 x 1\/2&#8243; Phillips Bolts (#100103) and 2 x #4-40 Nuts #102154) for metal reels Phillips Screwdriver #4-40 Spanner (for metal reels) Wire Cutters and Strippers (if required) Soldering Wire and Iron (if required) 1. Remove the battery drawer from the faceplate. Note: To remove the battery drawer, press the drawer in, lift, then pull. The battery drawer should slide out of the faceplate enough to allow it to be pulled out and removed. 2. Undo the three screws from the front of the faceplate and remove the faceplate from the reel. 3. For Meters with a Molex connection, undo the connector that links the faceplate electronics to the tape. 4. For Meters with the tape leads connected to the circuit board, press down on the white terminals of the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":222487,"parent":222521,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"folder":[410],"class_list":["post-222484","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.5 (Yoast SEO v27.5) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Solinst 101D Water Level DrawDown Meter Battery Drawer Replacement<\/title>\n<meta name=\"description\" content=\"To remove the battery drawer from Solinst 101D Water Level DrawDown Meters, press the drawer in, lift, then pull. The battery drawer should slide out of the faceplate enough to allow it to be pulled out and removed.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.solinst.com\/en-gb\/products\/level-measurement-devices\/101d-water-level-drawdown-meter\/101d-water-level-drawdown-meter-instructions\/battery-drawer-replacement\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Battery Drawer Replacement\" \/>\n<meta property=\"og:description\" content=\"Discover how to perform a Water Level DrawDown Meter battery drawer replacement easily and effectively.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solinst.com\/en-gb\/products\/level-measurement-devices\/101d-water-level-drawdown-meter\/101d-water-level-drawdown-meter-instructions\/battery-drawer-replacement\/\" \/>\n<meta property=\"og:site_name\" content=\"Solinst Groundwater and Surface Water Monitoring Instrumentation, Water Level Meters, Interface Meters, Dataloggers\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-07T22:34:30+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solinst.com\/wp-content\/uploads\/2025\/12\/featureimages-lmd-101d-battery-replacement-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:description\" content=\"Discover how to perform a Water Level DrawDown Meter battery drawer replacement easily and effectively.\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"19 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/products\\\/level-measurement-devices\\\/101d-water-level-drawdown-meter\\\/101d-water-level-drawdown-meter-instructions\\\/battery-drawer-replacement\\\/\",\"url\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/products\\\/level-measurement-devices\\\/101d-water-level-drawdown-meter\\\/101d-water-level-drawdown-meter-instructions\\\/battery-drawer-replacement\\\/\",\"name\":\"Solinst 101D Water Level DrawDown Meter Battery Drawer Replacement\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/products\\\/level-measurement-devices\\\/101d-water-level-drawdown-meter\\\/101d-water-level-drawdown-meter-instructions\\\/battery-drawer-replacement\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/products\\\/level-measurement-devices\\\/101d-water-level-drawdown-meter\\\/101d-water-level-drawdown-meter-instructions\\\/battery-drawer-replacement\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.solinst.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/featureimages-lmd-101d-battery-replacement-1.webp\",\"datePublished\":\"2025-11-10T22:40:39+00:00\",\"dateModified\":\"2026-05-07T22:34:30+00:00\",\"description\":\"To remove the battery drawer from Solinst 101D Water Level DrawDown Meters, press the drawer in, lift, then pull. The battery drawer should slide out of the faceplate enough to allow it to be pulled out and removed.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/products\\\/level-measurement-devices\\\/101d-water-level-drawdown-meter\\\/101d-water-level-drawdown-meter-instructions\\\/battery-drawer-replacement\\\/#breadcrumb\"},\"inLanguage\":\"en-gb\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/products\\\/level-measurement-devices\\\/101d-water-level-drawdown-meter\\\/101d-water-level-drawdown-meter-instructions\\\/battery-drawer-replacement\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-gb\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/products\\\/level-measurement-devices\\\/101d-water-level-drawdown-meter\\\/101d-water-level-drawdown-meter-instructions\\\/battery-drawer-replacement\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.solinst.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/featureimages-lmd-101d-battery-replacement-1.webp\",\"contentUrl\":\"https:\\\/\\\/www.solinst.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/featureimages-lmd-101d-battery-replacement-1.webp\",\"width\":1200,\"height\":675},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/products\\\/level-measurement-devices\\\/101d-water-level-drawdown-meter\\\/101d-water-level-drawdown-meter-instructions\\\/battery-drawer-replacement\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/home\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Battery Drawer Replacement\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/#website\",\"url\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/\",\"name\":\"Solinst Groundwater and Surface Water Monitoring Instrumentation, Water Level Meters, Interface Meters, Dataloggers\",\"description\":\"High quality groundwater monitoring instruments and surface water monitoring instruments including water level meters, interface meters, groundwater samplers, dataloggers and more!\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.solinst.com\\\/en-gb\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-gb\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Solinst 101D Water Level DrawDown Meter Battery Drawer Replacement","description":"To remove the battery drawer from Solinst 101D Water Level DrawDown Meters, press the drawer in, lift, then pull. The battery drawer should slide out of the faceplate enough to allow it to be pulled out and removed.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.solinst.com\/en-gb\/products\/level-measurement-devices\/101d-water-level-drawdown-meter\/101d-water-level-drawdown-meter-instructions\/battery-drawer-replacement\/","og_locale":"en_US","og_type":"article","og_title":"Battery Drawer Replacement","og_description":"Discover how to perform a Water Level DrawDown Meter battery drawer replacement easily and effectively.","og_url":"https:\/\/www.solinst.com\/en-gb\/products\/level-measurement-devices\/101d-water-level-drawdown-meter\/101d-water-level-drawdown-meter-instructions\/battery-drawer-replacement\/","og_site_name":"Solinst Groundwater and Surface Water Monitoring Instrumentation, Water Level Meters, Interface Meters, Dataloggers","article_modified_time":"2026-05-07T22:34:30+00:00","og_image":[{"width":1200,"height":675,"url":"https:\/\/www.solinst.com\/wp-content\/uploads\/2025\/12\/featureimages-lmd-101d-battery-replacement-1.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_description":"Discover how to perform a Water Level DrawDown Meter battery drawer replacement easily and effectively.","twitter_misc":{"Est. reading time":"19 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.solinst.com\/en-gb\/products\/level-measurement-devices\/101d-water-level-drawdown-meter\/101d-water-level-drawdown-meter-instructions\/battery-drawer-replacement\/","url":"https:\/\/www.solinst.com\/en-gb\/products\/level-measurement-devices\/101d-water-level-drawdown-meter\/101d-water-level-drawdown-meter-instructions\/battery-drawer-replacement\/","name":"Solinst 101D Water Level DrawDown Meter Battery Drawer Replacement","isPartOf":{"@id":"https:\/\/www.solinst.com\/en-gb\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solinst.com\/en-gb\/products\/level-measurement-devices\/101d-water-level-drawdown-meter\/101d-water-level-drawdown-meter-instructions\/battery-drawer-replacement\/#primaryimage"},"image":{"@id":"https:\/\/www.solinst.com\/en-gb\/products\/level-measurement-devices\/101d-water-level-drawdown-meter\/101d-water-level-drawdown-meter-instructions\/battery-drawer-replacement\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solinst.com\/wp-content\/uploads\/2025\/12\/featureimages-lmd-101d-battery-replacement-1.webp","datePublished":"2025-11-10T22:40:39+00:00","dateModified":"2026-05-07T22:34:30+00:00","description":"To remove the battery drawer from Solinst 101D Water Level DrawDown Meters, press the drawer in, lift, then pull. The battery drawer should slide out of the faceplate enough to allow it to be pulled out and removed.","breadcrumb":{"@id":"https:\/\/www.solinst.com\/en-gb\/products\/level-measurement-devices\/101d-water-level-drawdown-meter\/101d-water-level-drawdown-meter-instructions\/battery-drawer-replacement\/#breadcrumb"},"inLanguage":"en-gb","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solinst.com\/en-gb\/products\/level-measurement-devices\/101d-water-level-drawdown-meter\/101d-water-level-drawdown-meter-instructions\/battery-drawer-replacement\/"]}]},{"@type":"ImageObject","inLanguage":"en-gb","@id":"https:\/\/www.solinst.com\/en-gb\/products\/level-measurement-devices\/101d-water-level-drawdown-meter\/101d-water-level-drawdown-meter-instructions\/battery-drawer-replacement\/#primaryimage","url":"https:\/\/www.solinst.com\/wp-content\/uploads\/2025\/12\/featureimages-lmd-101d-battery-replacement-1.webp","contentUrl":"https:\/\/www.solinst.com\/wp-content\/uploads\/2025\/12\/featureimages-lmd-101d-battery-replacement-1.webp","width":1200,"height":675},{"@type":"BreadcrumbList","@id":"https:\/\/www.solinst.com\/en-gb\/products\/level-measurement-devices\/101d-water-level-drawdown-meter\/101d-water-level-drawdown-meter-instructions\/battery-drawer-replacement\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.solinst.com\/en-gb\/home\/"},{"@type":"ListItem","position":2,"name":"Battery Drawer Replacement"}]},{"@type":"WebSite","@id":"https:\/\/www.solinst.com\/en-gb\/#website","url":"https:\/\/www.solinst.com\/en-gb\/","name":"Solinst Groundwater and Surface Water Monitoring Instrumentation, Water Level Meters, Interface Meters, Dataloggers","description":"High quality groundwater monitoring instruments and surface water monitoring instruments including water level meters, interface meters, groundwater samplers, dataloggers and more!","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solinst.com\/en-gb\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-gb"}]}},"_links":{"self":[{"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/pages\/222484","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/comments?post=222484"}],"version-history":[{"count":12,"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/pages\/222484\/revisions"}],"predecessor-version":[{"id":222534,"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/pages\/222484\/revisions\/222534"}],"up":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/pages\/222521"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/media\/222487"}],"wp:attachment":[{"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/media?parent=222484"}],"wp:term":[{"taxonomy":"folder","embeddable":true,"href":"https:\/\/www.solinst.com\/en-gb\/wp-json\/wp\/v2\/folder?post=222484"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}