{"id":154681,"date":"2026-01-09T20:51:33","date_gmt":"2026-01-09T20:51:33","guid":{"rendered":"https:\/\/www.solinst.com\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/"},"modified":"2026-03-20T21:26:34","modified_gmt":"2026-03-20T21:26:34","slug":"levelogger-faq-preguntas-mas-frecuentes","status":"publish","type":"page","link":"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/","title":{"rendered":"Levelogger FAQ Preguntas m\u00e1s frecuentes"},"content":{"rendered":"<p>[et_pb_section fb_built=\u00bb1&#8243; admin_label=\u00bbH1 and breadcrumbs\u00bb _builder_version=\u00bb4.27.2&#8243; _module_preset=\u00bb792ca5bd-0808-46bd-9ce7-3bcb8e74f4d3&#8243; global_colors_info=\u00bb{}\u00bb][et_pb_row _builder_version=\u00bb4.27.2&#8243; _module_preset=\u00bb4b28f470-0d73-4e9d-b92d-e6f41f2cea24&#8243; global_colors_info=\u00bb{}\u00bb][et_pb_column type=\u00bb4_4&#8243; _builder_version=\u00bb4.25.0&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_heading title=\u00bbSolinst 3001 Levelogger FAQ Preguntas m\u00e1s frecuentes\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bb6983e4e7-a6e0-4a8d-b486-49939fd240c0&#8243; hover_enabled=\u00bb0&#8243; sticky_enabled=\u00bb0&#8243;][\/et_pb_heading][dsm_breadcrumbs disabled_on=\u00bbon|off|off\u00bb _builder_version=\u00bb4.27.2&#8243; _module_preset=\u00bbdefault\u00bb home_icon_text_color=\u00bb#d6d6d6&#8243; global_colors_info=\u00bb{}\u00bb][\/dsm_breadcrumbs][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=\u00bb1&#8243; admin_label=\u00bbMobile-Only Nav with Offset\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bb4759a92f-4b27-4854-bb2c-299854634e93&#8243; display_conditions=\u00bbW10=\u00bb sticky_offset_top=\u00bb127px\u00bb global_module=\u00bb63418&#8243; saved_tabs=\u00bball\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_row _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb width=\u00bb90%\u00bb custom_margin=\u00bb0px||||false|false\u00bb custom_padding=\u00bb0px||||false|false\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_column type=\u00bb4_4&#8243; _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_code admin_label=\u00bb3001 Levelogger Mobile Nav &#8211; Seleccionar desplegable\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb custom_css_free_form=\u00bbselect {||||      font-size: 1em; \/* Adjust font size *\/||      padding: 10px;   \/* Optional: Increase padding for better spacing *\/||      width: 100%;||      box-sizing: border-box;\/* Optional: Adjust width to fit the container *\/||      height: 50px;||}||||    \/* Style for dropdown options (fallback if needed) *\/||select option {||      font-size: 1.2em; \/* Ensures option text matches select styling *\/||      width: 100%;||    }\u00bb global_colors_info=\u00bb{}\u00bb]<select name=\"dropdown\" onchange=\"location = this.value;\"><!-- [et_pb_line_break_holder] --><option value=\"\">3001 Men\u00fa Levelogger 5<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/instruments\/dataloggers-and-telemetry-systems\/3001-levelogger\/\">3001 Levelogger 5 P\u00e1gina principal<\/option><!-- [et_pb_line_break_holder] -->    <!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/get-quote.php\">Pedir presupuesto<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/Forms\/sol.php\">Env\u00edame informaci\u00f3n<\/option><!-- [et_pb_line_break_holder] -->    <!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/getting-started\/getting-started.php\">Primeros pasos con Leveloggers<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/getting-started\/getting-started.php#min-req\">-Requisitos m\u00ednimos<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/getting-started\/getting-started.php#deployment\">-Opciones de despliegue<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/getting-started\/getting-started.php#in-field-cables\">-Cables\/Adaptadores de Comunicaci\u00f3n en el Campo<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/getting-started\/getting-started.php#in-field-devices\">-Dispositivos de comunicaci\u00f3n sobre el terreno<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/getting-started\/getting-started.php#accessories\">-Accesorios de despliegue opcionales<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/getting-started\/getting-started.php#other-req\">-Otros requisitos<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/getting-started\/getting-started.php#remote-data\">-Opciones de Datos Remotos<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/getting-started\/3001-getting-started.pdf\">-Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] -->    <!-- [et_pb_line_break_holder] --><option value=\"\/instruments\/dataloggers-and-telemetry-systems\/3001-levelogger\/levelogger-water-level-dataloggers\/\">Ficha<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/instruments\/dataloggers-and-telemetry-systems\/3001-levelogger\/levelogger-water-level-dataloggers\/ideal-applications-for-leveloggers\/\">-Aplicaciones ideales para Leveloggers<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/instruments\/dataloggers-and-telemetry-systems\/3001-levelogger\/levelogger-water-level-dataloggers\/programming-solinst-leveloggers\/\">-Programaci\u00f3n Solinst Leveloggers<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/instruments\/dataloggers-and-telemetry-systems\/3001-levelogger\/levelogger-water-level-dataloggers\/levelogger-well-cap-assembly\/\">-Conjunto del tap\u00f3n del pozo del nivelador<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/instruments\/dataloggers-and-telemetry-systems\/3001-levelogger\/levelogger-water-level-dataloggers\/levelogger-deployment-options\/\">-Opciones de despliegue de Levelogger<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/instruments\/dataloggers-and-telemetry-systems\/3001-levelogger\/levelogger-water-level-dataloggers\/barologger-for-barometric-compensation\/\">-Barologger para compensaci\u00f3n barom\u00e9trica<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/instruments\/dataloggers-and-telemetry-systems\/3001-levelogger\/levelogger-water-level-dataloggers\/solinst-levelogger-specifications\/\">-Especificaciones del Levelogger 5<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/instruments\/dataloggers-and-telemetry-systems\/3001-levelogger\/levelogger-water-level-dataloggers\/levelogger-portable-data-transfer-and-telemetry\/\">-Transferencia de datos y telemetr\u00eda port\u00e1tiles Levelogger<\/option><!-- [et_pb_line_break_holder] -->    <!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/\">Instrucciones<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/quick-start-guide\/\">-Gu\u00eda de inicio r\u00e1pido del Levelogger Serie 5<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/quick-start-guide\/3001-quick-start-guide.pdf\">&#8211;Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/user-guide\/3001-user-guide.php\">-Gu\u00eda del usuario del software Levelogger Serie 5<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/user-guide\/3001-user-guide.pdf\">&#8211;Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/leveloader\/operating-instructions\/quick-start-guide\/3001-leveloader-quick-start-guide.pdf\">-Gu\u00eda de inicio r\u00e1pido de Leveloader\u2122 (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/leveloader\/operating-instructions\/user-guide\/\">-Gu\u00eda del usuario de Leveloader\u2122.<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/leveloader\/operating-instructions\/user-guide\/3001-leveloader-user-guide.pdf\">&#8211;Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/levelogger-deployment.php\">-Despliegue y comunicaci\u00f3n de Levelogger<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/levelogger-deployment.pdf\">&#8211;Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/3001-5-vs-edge.php\">-Levelogger 5 vs. Levelogger Edge<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/3001-5-vs-edge.pdf\">&#8211;Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/3001-5-vs-3250.php\">-Comparaci\u00f3n de registradores de datos de nivel de agua &#8211; Levelogger 5 vs. LevelVent<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/3001-5-vs-3250.pdf\">&#8211;Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/sdi-12-user-guide\/sdi-12-user-guide.php\">-Gu\u00eda del usuario de SDI-12<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/sdi-12-user-guide\/sdi-12-user-guide.pdf\">&#8211;Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/modbus-user-guide\/modbus-user-guide.pdf\">-Gu\u00eda del usuario de MODBUS (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/artesian-well-fitting.php\">-Conjunto de accesorios de pozo art\u00edstico<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/artesian-well-fitting.pdf\">&#8211;Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/optical-adaptors\/optical-adaptors.php\">-Adaptadores \u00f3pticos L5<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/levelogger-direct-read-optical-adaptor.pdf\">&#8211;Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/levelogger-5-adaptors.pdf\">-Adaptadores Levelogger 5 (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/connect-drc-reel.php\">-Conexi\u00f3n del cable de lectura directa a la bobina<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/connect-drc-reel.pdf\">&#8211;Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] --><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/product-tour\/\">Recorrido por los productos<\/option><!-- [et_pb_line_break_holder] -->    <!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/technical-bulletins\/\">Boletines t\u00e9cnicos<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/\">-Compensaci\u00f3n barom\u00e9trica e importancia de los datos barom\u00e9tricos<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/technical-bulletins\/barometric-compensation.pdf\">&#8211;Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/technical-bulletins\/automatic-manual-barometric-compensation.php\">-Compensaci\u00f3n barom\u00e9trica autom\u00e1tica o manual de los datos de tu Detector de nivel<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/technical-bulletins\/automatic-manual-barometric-compensation.pdf\">&#8211;Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/simplify-your-pumping-test-with-a-water-level-datalogger\/\">-Simplifica tu prueba de bombeo&#8230; Utiliza un registrador de datos del nivel del agua<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/technical-bulletins\/simplify-your-pumping-test.pdf\">&#8211;Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/\">-Comprensi\u00f3n de la exactitud, precisi\u00f3n, resoluci\u00f3n y deriva del sensor de presi\u00f3n<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/technical-bulletins\/understanding-pressure-sensor-drift.pdf\">&#8211;Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-levelogger-battery-life\/\">-Comprender la duraci\u00f3n de la bater\u00eda<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/technical-bulletins\/understanding-battery-life.pdf\">&#8211;Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/ensuring-proper-use-and-levelogger-maintenance\/\">-Asegurar el uso y mantenimiento adecuados de los Leveloggers<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/technical-bulletins\/3001leveloggermaintenance.pdf\">&#8211;Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/\">-Conductividad, Nivel y Temperatura manuales o autom\u00e1ticos<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/technical-bulletins\/manual-automatic-conductivity-level-temperature.pdf\">&#8211;Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/onthelevel-news\/2016\/01\/long-term-open-channel-surface-water-monitoring-with-leveloggers\/\">-Vigilancia a largo plazo de canales abiertos y aguas superficiales con Leveloggers<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/technical-bulletins\/surface-water-monitoring.pdf\">&#8211;Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/onthelevel-news\/2016\/07\/absolute-vs-vented\/\">-Dataloggers absolutos vs. Dataloggers ventilados<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3500-aquavent\/technical-bulletins\/3500-absolute-vs-vented.pdf\">&#8211;Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] -->    <!-- [et_pb_line_break_holder] --><option value=\"\/instruments\/dataloggers-and-telemetry-systems\/3001-levelogger\/levelogger-faq-frequently-asked-questions\/\">Levelogger 5 FAQ<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/levelogger-faq\/3001-faq.pdf\">-Descargar (PDF)<\/option><!-- [et_pb_line_break_holder] -->    <!-- [et_pb_line_break_holder] --><option value=\"\/products\/data\/3001compatibility.pdf\">Compatibilidad de hardware (PDF)<\/option><!-- [et_pb_line_break_holder] --><option value=\"\/products\/data\/datalogger-comparison.pdf\">Comparaci\u00f3n de registradores de datos (PDF)<\/option><!-- [et_pb_line_break_holder] -->    <!-- [et_pb_line_break_holder] --><\/select>[\/et_pb_code][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=\u00bb1&#8243; specialty=\u00bbon\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bb5a5bca26-a9a5-4e6c-8fca-d64da3bdcd40&#8243; global_colors_info=\u00bb{}\u00bb][et_pb_column type=\u00bb1_4&#8243; _builder_version=\u00bb4.16&#8243; custom_padding=\u00bb|||\u00bb global_colors_info=\u00bb{}\u00bb custom_padding__hover=\u00bb|||\u00bb][et_pb_menu menu_id=\u00bb331&#8243; admin_label=\u00bb3001 Levelogger Main Nav\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bb242faa89-ac4f-4e46-90fe-505e8c1eab79&#8243; global_module=\u00bb63349&#8243; global_colors_info=\u00bb{}\u00bb][\/et_pb_menu][et_pb_slider disabled_on=\u00bbon|on|off\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb display_conditions=\u00bbW10=\u00bb link_option_url=\u00bbhttps:\/\/downloads.solinst.com\/free-shipping?utm_source=solinst&#038;utm_medium=WC-global-sidebar-position1&#038;utm_campaign=free-shipping\u00bb disabled=\u00bbon\u00bb global_module=\u00bb53188&#8243; saved_tabs=\u00bball\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_slide button_text=\u00bbVentajas del uso de la flauta de agua\u00bb button_link=\u00bbhttps:\/\/www.solinst.com\/es\/productos\/flauta-solinst\/405-flauta-de-agua\/?utm_source=solinst&amp;utm_medium=WC-global-sidebar-position1&amp;utm_campaign=405-water-flute\u00bb use_bg_overlay=\u00bbon\u00bb bg_overlay_color=\u00bbrgba(224,97,0,0.58)\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb background_color=\u00bb#F07C00&#8243; background_enable_color=\u00bbon\u00bb background_image=\u00bbhttps:\/\/www.solinst.com\/wp-content\/uploads\/2024\/12\/405-water-flute-multilevel-groundwater-system-installation.webp\u00bb background_enable_image=\u00bbon\u00bb background_position=\u00bbtop_center\u00bb custom_button=\u00bbon\u00bb button_bg_color=\u00bb#f58025&#8243; button_border_width=\u00bb2px\u00bb button_border_radius=\u00bb20px\u00bb button_font=\u00bb|600|||||||\u00bb background_last_edited=\u00bbon|desktop\u00bb global_colors_info=\u00bb{}\u00bb sticky_transition=\u00bbon\u00bb]<\/p>\n<h2><strong><\/strong><\/h2>\n<h2><strong><\/strong><\/h2>\n<h2><strong><\/strong><\/h2>\n<p>&nbsp;<\/p>\n<h2>Control discreto de la profundidad de las aguas subterr\u00e1neas<\/h2>\n<p><b>Reducir costes y tiempo de campo<\/b><\/p>\n<p>[\/et_pb_slide][\/et_pb_slider][et_pb_slider disabled_on=\u00bbon|on|off\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb link_option_url=\u00bbhttps:\/\/www.solinst.com\/instruments\/groundwater-samplers\/410-peristaltic-pumps\/?utm_source=solinst&#038;utm_medium=WC-global-sidebar-position2&#038;utm_campaign=410-101d\u00bb disabled=\u00bbon\u00bb global_module=\u00bb53561&#8243; saved_tabs=\u00bball\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_slide heading=\u00bbBombeo autom\u00e1tico con modo DrawDown\u00bb button_text=\u00bbNueva bomba perist\u00e1ltica Mk5&#8243; button_link=\u00bbhttps:\/\/www.solinst.com\/es\/productos\/muestreadores-de-aguas-subterraneas\/410-bombas-peristalticas\/?utm_source=solinst&amp;utm_medium=WC-global-sidebar-position2&amp;utm_campaign=410-101d\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb header_text_color=\u00bb#000000&#8243; background_color=\u00bbRGBA(255,255,255,0)\u00bb background_enable_color=\u00bbon\u00bb background_image=\u00bbhttps:\/\/www.solinst.com\/wp-content\/uploads\/2026\/01\/101d-water-level-drawdown-meter-2-965&#215;500-1.webp\u00bb background_enable_image=\u00bbon\u00bb background_size=\u00bbcontain\u00bb custom_button=\u00bbon\u00bb button_bg_color=\u00bb#f58025&#8243; button_border_width=\u00bb2px\u00bb button_border_radius=\u00bb20px\u00bb button_font=\u00bb|600|||||||\u00bb button_custom_margin=\u00bb||||false|false\u00bb button_custom_padding=\u00bb1px||||false|false\u00bb custom_padding=\u00bb76px||||false|false\u00bb header_text_shadow_style=\u00bbpreset3&#8243; global_colors_info=\u00bb{}\u00bb sticky_transition=\u00bbon\u00bb]<\/p>\n<h2\/>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>[\/et_pb_slide][\/et_pb_slider][et_pb_image src=\u00bbhttps:\/\/www.solinst.com\/wp-content\/uploads\/2025\/02\/3001-solinst-levelogger-pc-software.webp\u00bb alt=\u00bbsolinst levelogger pc software\u00bb title_text=\u00bbSolinst Levelogger Software para PC\u00bb url=\u00bbhttps:\/\/downloads.solinst.com\/?utm_source=solinst&amp;utm_medium=WC&amp;utm_campaign=sidebarbanner&amp;utm_term=solinstsoftware-image\u00bb align=\u00bbcenter\u00bb disabled_on=\u00bbon|on|off\u00bb admin_label=\u00bbLevelogger Software Box\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb z_index=\u00bb1&#8243; width=\u00bb75%\u00bb sticky_position=\u00bbtop\u00bb sticky_offset_top=\u00bb10px\u00bb sticky_limit_bottom=\u00bbbody\u00bb motion_trigger_start=\u00bbtop\u00bb global_module=\u00bb1022&#8243; global_colors_info=\u00bb{}\u00bb][\/et_pb_image][et_pb_button button_url=\u00bbhttps:\/\/downloads.solinst.com\/?utm_source=solinst&amp;utm_medium=WC&amp;utm_campaign=sidebarbanner&amp;utm_term=solinstsoftware-image\u00bb button_text=\u00bbDescargas gratuitas de software\u00bb button_alignment=\u00bbcenter\u00bb disabled_on=\u00bbon|on|off\u00bb admin_label=\u00bbfree software\u00bb _builder_version=\u00bb4.27.2&#8243; _module_preset=\u00bbdefault\u00bb custom_button=\u00bbon\u00bb button_text_size=\u00bb24px\u00bb button_text_color=\u00bb#FFFFFF\u00bb button_bg_color=\u00bb#ff8500&#8243; button_bg_enable_image=\u00bboff\u00bb button_border_color=\u00bb#ff8500&#8243; button_border_radius=\u00bb20px\u00bb button_font=\u00bb|600|||||||\u00bb button_icon=\u00bb&#xe046;||divi||400&#8243; z_index=\u00bb2&#8243; custom_padding=\u00bb6px|25px|6px|25px|false|false\u00bb sticky_position=\u00bbtop\u00bb sticky_offset_top=\u00bb10px\u00bb sticky_limit_bottom=\u00bbbody\u00bb motion_trigger_start=\u00bbtop\u00bb global_module=\u00bb1024&#8243; global_colors_info=\u00bb{}\u00bb][\/et_pb_button][\/et_pb_column][et_pb_column type=\u00bb3_4&#8243; specialty_columns=\u00bb3&#8243; _builder_version=\u00bb4.16&#8243; custom_padding=\u00bb|||\u00bb global_colors_info=\u00bb{}\u00bb custom_padding__hover=\u00bb|||\u00bb][et_pb_row_inner _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bb3d68e16c-1ed2-447f-b17f-a63c20af3cf6&#8243; locked=\u00bboff\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_column_inner saved_specialty_column_type=\u00bb3_4&#8243; _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][dsm_icon_list icon_font_size=\u00bb30px\u00bb list_alignment=\u00bbflex-end\u00bb text_indent=\u00bb10px\u00bb list_alignment_tablet=\u00bbflex-end\u00bb list_alignment_phone=\u00bbflex-start\u00bb list_alignment_last_edited=\u00bbon|desktop\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb text_font=\u00bb|600|||||||\u00bb link_option_url_new_window=\u00bbon\u00bb global_colors_info=\u00bb{}\u00bb][dsm_icon_list_child text=\u00bb3001 Levelogger 5 FAQ PDF\u00bb font_icon=\u00bb&#xf1c1;||fa||900&#8243; icon_color=\u00bb#ff8500&#8243; url=\u00bbhttps:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/levelogger-faq\/3001-faq.pdf\u00bb url_new_window=\u00bbon\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb icon_color__hover_enabled=\u00bbon|hover\u00bb icon_color__hover=\u00bb#828282&#8243; text_text_color__hover_enabled=\u00bbon|hover\u00bb text_text_color__hover=\u00bb#7a7a7a\u00bb][\/dsm_icon_list_child][\/dsm_icon_list][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bb3676f7e6-7b83-4698-94ce-2cc9fa9ae43d\u00bb hover_enabled=\u00bb0&#8243; global_colors_info=\u00bb{}\u00bb sticky_enabled=\u00bb0&#8243;][et_pb_column_inner saved_specialty_column_type=\u00bb3_4&#8243; _builder_version=\u00bb4.27.2&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_text admin_label=\u00bbresearch article\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb hover_enabled=\u00bb0&#8243; global_colors_info=\u00bb{}\u00bb sticky_enabled=\u00bb0&#8243;]<\/p>\n<h2><strong>Preguntas generales frecuentes sobre Levelogger<\/strong><\/h2>\n<p>[\/et_pb_text][dsm_faq dsm_make_accordion_toggle=\u00bbon\u00bb dsm_animate_icon=\u00bbon\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bb77be2b9f-999b-455f-afb8-d94da1ded8dc\u00bb global_colors_info=\u00bb{}\u00bb][dsm_faq_child dsm_title=\u00bb\u00bfCu\u00e1l es la diferencia entre un Levelogger y un Barologger?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>Los Leveloggers registran los cambios en la presi\u00f3n absoluta (presi\u00f3n de la columna de agua + presi\u00f3n barom\u00e9trica) con el tiempo. El Barologger funciona y se comunica de forma similar al Levelogger, pero se utiliza por encima del nivel del agua para registrar la presi\u00f3n barom\u00e9trica ambiente con el fin de corregir barom\u00e9tricamente los datos registrados por los Leveloggers. Normalmente, un Barologger puede cubrir un radio de 30 km (20 millas) y\/o cada 300 m (1000 pies) de cambio de elevaci\u00f3n.  <\/li>\n<li>V\u00e9ase el bolet\u00edn t\u00e9cnico:<span> <\/span><a href=%22https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/%22 title=%22Importancia de la compensaci\u00f3n barom\u00e9trica y los datos barom\u00e9tricos%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/%22>Compensaci\u00f3n barom\u00e9trica e importancia de los datos barom\u00e9tricos<\/a><\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_0&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfCu\u00e1l es la diferencia entre los sensores de presi\u00f3n absoluta y los sensores de presi\u00f3n ventilados (manom\u00e9tricos)?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>V\u00e9ase el bolet\u00edn t\u00e9cnico:<span> <\/span><a href=%22https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/absolute-vs-vented\/%22 title=%22Registradores de datos de nivel de agua absolutos comparados con registradores de datos de nivel de agua ventilados: Diferencias%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/absolute-vs-vented\/%22>Registradores de datos de nivel de agua absolutos y ventilados: \u00bfqu\u00e9 m\u00e9todo es el adecuado para su proyecto?<\/a><\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_0&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfC\u00f3mo selecciono el rango de presi\u00f3n correcto del Levelogger para mi aplicaci\u00f3n?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>La elecci\u00f3n del rango de presi\u00f3n depende en gran medida de la precisi\u00f3n del nivel de agua requerido y de la profundidad de inmersi\u00f3n deseada. No obstante, la selecci\u00f3n debe basarse en la fluctuaci\u00f3n m\u00e1xima prevista del nivel del agua. <\/li>\n<li>Ejemplo: El Levelogger 5 M5 est\u00e1 dise\u00f1ado para una inmersi\u00f3n de 5 metros o 15 pies y proporciona una precisi\u00f3n t\u00edpica del nivel de agua de \u00b13 mm (0,01 pies). Este instrumento es ideal para aplicaciones en aguas superficiales y subterr\u00e1neas poco profundas, donde es esencial medir con precisi\u00f3n el nivel del agua. <\/li>\n<li>Sin embargo, si la fluctuaci\u00f3n prevista del nivel del agua es superior a la gama dise\u00f1ada, deber\u00e1 elegirse la siguiente gama disponible para esa aplicaci\u00f3n.<\/li>\n<li>Ejemplo: Se espera una fluctuaci\u00f3n del nivel del agua de 10 metros (30 pies). Para protegerse de un posible exceso de rango, debe seleccionarse el siguiente instrumento de rango de presi\u00f3n disponible (Levelogger 5 M20). <\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_0&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfC\u00f3mo s\u00e9 si estoy utilizando la versi\u00f3n m\u00e1s reciente de software y firmware?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>Las versiones m\u00e1s recientes de software y firmware del Levelogger est\u00e1n disponibles en el sitio web de Solinst<span> <\/span><a href=%22https:\/\/downloads.solinst.com\/solinst-software-firmware-downloads\/bf666c8da49%22 data-et-target-link=%22_blank%22 title=%22P\u00e1gina de descargas de Solinst%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22https:\/\/downloads.solinst.com\/solinst-software-firmware-downloads\/bf666c8da49%22 aria-label=%22Downloads - open in a new tab%22 data-uw-rm-ext-link=%22%22 uw-rm-external-link-id=%22https:\/\/downloads.solinst.com\/solinst-software-firmware-downloads\/bf666c8da49$downloads%22 rel=%22noopener%22>Descargas<\/a><span> <\/span>p\u00e1gina. Puedes comprobar de vez en cuando si tienes la versi\u00f3n m\u00e1s reciente o, si registras el software cuando lo descargues, recibir\u00e1s mensajes de correo electr\u00f3nico autom\u00e1ticos que te avisar\u00e1n cuando haya nuevo software o firmware disponible. <\/li>\n<li>Adem\u00e1s, cuando se utiliza la versi\u00f3n de software Levelogger (4.0.1 y superiores) en un ordenador con conexi\u00f3n a Internet, se proporcionar\u00e1n notificaciones autom\u00e1ticas cuando est\u00e9n disponibles nuevas versiones de software y firmware. Al hacer clic en el mensaje de notificaci\u00f3n, acceder\u00e1 directamente a la p\u00e1gina de descarga de software\/firmware. <\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_0&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfTengo que pagar por el software y el firmware?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>No, todas las versiones actuales de software y firmware est\u00e1n disponibles para su descarga gratuita en el sitio web de Solinst. Si registra el software cuando lo descargue, recibir\u00e1 avisos autom\u00e1ticos cuando se publique nuevo software o firmware. <\/li>\n<li>Consulte la p\u00e1gina de<a href=%22https:\/\/downloads.solinst.com\/solinst-software-firmware-downloads\/bf666c8da49%22 data-et-target-link=%22_blank%22 title=%22Descargas de software Solinst%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22https:\/\/downloads.solinst.com\/solinst-software-firmware-downloads\/bf666c8da49%22 aria-label=%22Downloads - open in a new tab%22 data-uw-rm-ext-link=%22%22 uw-rm-external-link-id=%22https:\/\/downloads.solinst.com\/solinst-software-firmware-downloads\/bf666c8da49$downloads%22 rel=%22noopener%22>descargas de<\/a> Solinst<span> <\/span><span> <\/span><\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_0&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfC\u00f3mo actualizo el software?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>Descargue gratuitamente nuevas versiones de software desde el sitio web de Solinst a medida que est\u00e9n disponibles.<\/li>\n<li>Consulte la p\u00e1gina de<a href=%22https:\/\/downloads.solinst.com\/solinst-software-firmware-downloads\/bf666c8da49%22 data-et-target-link=%22_blank%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22https:\/\/downloads.solinst.com\/solinst-software-firmware-downloads\/bf666c8da49%22 aria-label=%22Downloads - open in a new tab%22 data-uw-rm-ext-link=%22%22 uw-rm-external-link-id=%22https:\/\/downloads.solinst.com\/solinst-software-firmware-downloads\/bf666c8da49$downloads%22 rel=%22noopener%22>descargas de<\/a> Solinst<span> <\/span><span> <\/span><\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_0&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfC\u00f3mo actualizo el firmware de Levelogger?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>El software Levelogger viene equipado con una %22Utilidad de actualizaci\u00f3n de firmware%22. A medida que hay nuevas versiones de firmware disponibles, pueden descargarse gratuitamente de la p\u00e1gina web de Solinst y cargarse en su Levelogger utilizando la Utilidad. Aseg\u00farese de que el software es la \u00faltima versi\u00f3n, ya que contiene la Utilidad de Actualizaci\u00f3n de Firmware m\u00e1s reciente.  <\/li>\n<li>Consulte la p\u00e1gina de<a href=%22https:\/\/downloads.solinst.com\/solinst-software-firmware-downloads\/bf666c8da49%22 data-et-target-link=%22_blank%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22https:\/\/downloads.solinst.com\/solinst-software-firmware-downloads\/bf666c8da49%22 aria-label=%22Downloads - open in a new tab%22 data-uw-rm-ext-link=%22%22 uw-rm-external-link-id=%22https:\/\/downloads.solinst.com\/solinst-software-firmware-downloads\/bf666c8da49$downloads%22 rel=%22noopener%22>descargas de<\/a> Solinst<span> <\/span><span> <\/span><\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_0&#8243;][\/dsm_faq_child][\/dsm_faq][et_pb_button button_url=\u00bbhttps:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/get-quote.php\u00bb button_text=\u00bbObtener presupuesto\u00bb admin_label=\u00bb3001 get quote\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbc9e00792-1360-4998-8cf9-5f6772c944ba\u00bb custom_margin=\u00bb20px||||false|false\u00bb custom_padding=\u00bb6px|47px|6px|47px|false|false\u00bb global_module=\u00bb62109&#8243; saved_tabs=\u00bball\u00bb global_colors_info=\u00bb{}\u00bb][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bb3676f7e6-7b83-4698-94ce-2cc9fa9ae43d\u00bb hover_enabled=\u00bb0&#8243; global_colors_info=\u00bb{}\u00bb sticky_enabled=\u00bb0&#8243;][et_pb_column_inner saved_specialty_column_type=\u00bb3_4&#8243; _builder_version=\u00bb4.27.2&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_text admin_label=\u00bbresearch article\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb hover_enabled=\u00bb0&#8243; global_colors_info=\u00bb{}\u00bb sticky_enabled=\u00bb0&#8243;]<\/p>\n<h2><strong>Aplicaciones<\/strong><\/h2>\n<p>[\/et_pb_text][dsm_faq dsm_make_accordion_toggle=\u00bbon\u00bb dsm_animate_icon=\u00bbon\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bb77be2b9f-999b-455f-afb8-d94da1ded8dc\u00bb global_colors_info=\u00bb{}\u00bb][dsm_faq_child dsm_title=\u00bb\u00bfPara qu\u00e9 tipo de aplicaciones son adecuados los Leveloggers?\u00bb dsm_content=\u00bb<\/p>\n<p>Los Leveloggers son adecuados para las siguientes aplicaciones:<\/p>\n<ul>\n<li>Control a largo plazo de las aguas subterr\u00e1neas<\/li>\n<li>Medici\u00f3n de r\u00edos, lagos y arroyos<\/li>\n<li>Gesti\u00f3n de los recursos h\u00eddricos<\/li>\n<li>Pruebas de acu\u00edferos &#8211; bombeo, slug, step, recuperaci\u00f3n<\/li>\n<li>Control remoto con aplicaciones de telemetr\u00eda<\/li>\n<li>Control de las fluctuaciones portuarias y de las mareas y de la acci\u00f3n del oleaje<\/li>\n<li>Control del nivel de tanques industriales<\/li>\n<li>Gesti\u00f3n de la captaci\u00f3n\/bombeo de agua<\/li>\n<li>Estudios de recarga de cuencas hidrogr\u00e1ficas o de drenaje<\/li>\n<li>Control de los humedales y de la escorrent\u00eda de las aguas pluviales<\/li>\n<li>Control a largo plazo del nivel del agua en los pozos<\/li>\n<li>Control de presas, embalses y esclusas<\/li>\n<li>Desbordamiento del alcantarillado combinado (CSO) y gesti\u00f3n de las aguas pluviales<\/li>\n<li>Proyectos de desag\u00fce<\/li>\n<li>Observaci\u00f3n del almacenamiento y recuperaci\u00f3n de acu\u00edferos<\/li>\n<li>Control de la intrusi\u00f3n de agua salada y de la salinizaci\u00f3n del suelo<\/li>\n<li>Vigilancia y estudios de recuperaci\u00f3n de plumas<\/li>\n<li>Control de lixiviados en vertederos, escombreras y dep\u00f3sitos de residuos<\/li>\n<li>Aplicaciones de vigilancia de PFAS<\/li>\n<li>Pruebas de trazadores<\/li>\n<li>Control de la escorrent\u00eda agr\u00edcola y pluvial<\/li>\n<li><a href=%22https:\/\/www.solinst.com\/onthelevel-news\/%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/onthelevel-news\/%22>Y m\u00e1s&#8230;<\/a><\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_1&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfPuede utilizarse el Levelogger para el control continuo de las aguas subterr\u00e1neas?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>S\u00ed, los Leveloggers son registradores de datos aut\u00f3nomos dise\u00f1ados para registrar continuamente las fluctuaciones del nivel del agua y la temperatura a lo largo del tiempo. Los Leveloggers est\u00e1n disponibles en varios rangos de presi\u00f3n diferentes, que pueden utilizarse desde piez\u00f3metros poco profundos hasta la monitorizaci\u00f3n de pozos de bombeo profundos. El paquete de software del Levelogger de Solinst incluye funciones que le permiten incorporar mediciones manuales de campo del nivel del agua; realizar compensaciones barom\u00e9tricas; o ajustar los datos relativos a otro punto de referencia (profundidad al agua, elevaci\u00f3n de la superficie del suelo, etc.).  <\/li>\n<li>La supervisi\u00f3n remota mediante telemetr\u00eda tambi\u00e9n es una opci\u00f3n.<\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_1&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfSe puede utilizar el Levelogger en pruebas de bombeo?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>S\u00ed, los Leveloggers son excelentes para utilizar durante todas las pruebas de bombeo. El Levelogger 5 y el Levelogger 5 LTC se pueden programar con un calendario de muestreo personalizado que establece las tasas a las que se recogen los datos de nivel de agua para una serie de intervalos separados. Puede personalizar diferentes frecuencias de muestreo y duraciones para registrar las lecturas del nivel de agua antes, durante y despu\u00e9s de la prueba de bombeo (l\u00ednea de base, bombeo y recuperaci\u00f3n). Si se despliega en un cable de lectura directa, las lecturas en tiempo real del Levelogger se pueden ver y guardar en un ordenador port\u00e1til o dispositivo inteligente durante la prueba de bombeo.   <\/li>\n<li>Consulte el bolet\u00edn t\u00e9cnico:<span> <\/span><a href=%22https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/technical-bulletins\/simplify-your-pumping-test.php%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/technical-bulletins\/simplify-your-pumping-test.php%22>Simplifique su prueba de bombeo&#8230; Utilice un registrador de datos de nivel de agua<\/a><\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_1&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfPuedo colocar un Levelogger junto a una bomba el\u00e9ctrica de fondo?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>S\u00ed, debido al dise\u00f1o de la jaula de Faraday, todos los datos registrados internamente por el Levelogger no se ver\u00e1n afectados por el ruido el\u00e9ctrico cercano. Lo ideal, sin embargo, es que cuando se instale un Levelogger en un pozo con bomba, el Levelogger se coloque m\u00e1s all\u00e1 de cualquier interferencia potencial\/efecto de turbulencia de la entrada de la bomba. Si se utiliza un cable de lectura directa, tambi\u00e9n se recomienda una tuber\u00eda de inserci\u00f3n separada, que est\u00e9 conectada a tierra, para evitar posibles interferencias el\u00e9ctricas con la comunicaci\u00f3n cuando se recopilan o visualizan datos en modo de tiempo real. En ausencia de un tubo de inserci\u00f3n conectado a tierra, aseg\u00farese de que la bomba est\u00e9 apagada antes de establecer la interfaz a trav\u00e9s del cable de lectura directa.   <\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_1&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfSon adecuados los Leveloggers para aplicaciones en aguas superficiales?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>S\u00ed, los instrumentos Levelogger 5 M5, Levelogger 5 Junior y Levelogger 5 LTC utilizan un sensor de presi\u00f3n altamente sensible para una precisi\u00f3n y resoluci\u00f3n exactas del nivel del agua, ideal para aplicaciones en aguas superficiales (lagos, humedales, cuencas hidrogr\u00e1ficas, r\u00edos o arroyos). El Levelogger 5 M5 utilizado en t\u00e1ndem con un Barologger 5 puede alcanzar precisiones de nivel de agua de \u00b18 mm\/ 0,017 pies. <\/li>\n<li>Asimismo, considere la posibilidad de utilizar los registradores de datos de nivel de agua con ventilaci\u00f3n Solinst<span> <\/span><a href=%22https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3250-levelvent\/levelvent.php%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/products\/dataloggers-and-telemetry\/3250-levelvent\/levelvent.php%22>LevelVent 5<\/a><span> <\/span>o<span> <\/span><a href=%22https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3500-aquavent\/aquavent.php%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/products\/dataloggers-and-telemetry\/3500-aquavent\/aquavent.php%22>AquaVent 5<\/a><span> <\/span>para obtener la m\u00e1xima precisi\u00f3n en aplicaciones de aguas poco profundas.<\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_1&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfSe pueden utilizar Leveloggers en entornos de agua salada?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>S\u00ed, el Levelogger 5, el Levelogger 5 Junior y el Levelogger 5 LTC pueden utilizarse en la monitorizaci\u00f3n a corto y largo plazo en entornos de agua salada o salobre. El Levelogger 5 y el Levelogger 5 LTC tienen un revestimiento resistente a la corrosi\u00f3n. Sin embargo, en entornos m\u00e1s duros, puede proteger el Levelogger 5 Junior utilizando un globo lleno de fluido no corrosivo\/no t\u00f3xico (agua del grifo). A medida que cambia la presi\u00f3n, el fluido que recubre los registradores transmitir\u00e1 el diferencial de presi\u00f3n al transductor de presi\u00f3n del registrador, sin exponerlo a condiciones corrosivas. Consulte la Gu\u00eda del usuario de la serie Levelogger para obtener m\u00e1s recomendaciones de mantenimiento.    <\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_1&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfPuedo utilizar el mismo Levelogger en un arroyo poco profundo y luego en un pozo de aguas profundas?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>S\u00ed, pero como con cualquier sensor de presi\u00f3n, tenga en cuenta que al seleccionar un sensor de rango superior (por ejemplo, M100) proporciona menos precisi\u00f3n que un sensor de rango inferior (por ejemplo, M5). Elija el rango de presi\u00f3n que mejor se adapte a las necesidades de su programa de monitorizaci\u00f3n (sin sumergirse m\u00e1s all\u00e1 del rango calibrado). <\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_1&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfPuedo utilizar los Leveloggers de Solinst en mi proyecto de control de PFAS?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>S\u00ed, los PFAS no se utilizan ni est\u00e1n presentes a sabiendas en la fabricaci\u00f3n o producci\u00f3n de los productos Solinst. Los materiales h\u00famedos del Levelogger 5 son: revestimiento de PTFE resistente a la corrosi\u00f3n horneado mediante tecnolog\u00eda de polimerizaci\u00f3n, cono de nariz, filtro y tapa superior de acetal\/Delrin\u00ae, acero inoxidable 316L, sensor de presi\u00f3n de Hastelloy y junta t\u00f3rica de Viton\u00ae. El Levelogger 5 LTC tambi\u00e9n incluye: Una c\u00e9lula de conductividad de acetal y alambres de n\u00facleo de Niobio revestidos de Platino.  <\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_1&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfPuedo utilizar Solinst Leveloggers en aguas subterr\u00e1neas con un pH de 4?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>Como se recomienda con todos nuestros productos, antes de iniciar cualquier proyecto de control ambiental, es esencial tomar algunas medidas para evaluar si el equipo que elija funcionar\u00e1 como se espera en su lugar de control espec\u00edfico. Esto significa comparar los materiales h\u00famedos de su Levelogger con las condiciones y los productos qu\u00edmicos que espera encontrar en su proyecto de monitorizaci\u00f3n, incluido el pH. <\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_1&#8243;][\/dsm_faq_child][\/dsm_faq][et_pb_button button_url=\u00bbhttps:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/get-quote.php\u00bb button_text=\u00bbObtener presupuesto\u00bb admin_label=\u00bb3001 get quote\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbc9e00792-1360-4998-8cf9-5f6772c944ba\u00bb custom_margin=\u00bb20px||||false|false\u00bb custom_padding=\u00bb6px|47px|6px|47px|false|false\u00bb global_module=\u00bb62109&#8243; saved_tabs=\u00bball\u00bb global_colors_info=\u00bb{}\u00bb][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bb3676f7e6-7b83-4698-94ce-2cc9fa9ae43d\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_column_inner saved_specialty_column_type=\u00bb3_4&#8243; _builder_version=\u00bb4.27.2&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_text admin_label=\u00bbresearch article\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb hover_enabled=\u00bb0&#8243; global_colors_info=\u00bb{}\u00bb sticky_enabled=\u00bb0&#8243;]<\/p>\n<h2><strong>Instalaci\u00f3n<\/strong><\/h2>\n<p>[\/et_pb_text][dsm_faq dsm_make_accordion_toggle=\u00bbon\u00bb dsm_animate_icon=\u00bbon\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bb77be2b9f-999b-455f-afb8-d94da1ded8dc\u00bb global_colors_info=\u00bb{}\u00bb][dsm_faq_child dsm_title=\u00bb\u00bfA qu\u00e9 profundidad puedo instalar mi Levelogger?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<ul>\n<li>La profundidad de inmersi\u00f3n para el Levelogger (en el nivel de agua m\u00e1s alto esperado) se basa en el rango de presi\u00f3n especificado para el instrumento. En <span> <\/span><a href=%22https:\/\/www.solinst.com\/instruments\/dataloggers-and-telemetry-systems\/3001-levelogger\/%22 title=%22Registradores de datos de nivel de agua Solinst Levelogger 5%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/%22>Levelogger 5<\/a><span> <\/span>y<span> <\/span><a href=%22https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/ltc-levelogger\/%22 title=%22Registradores de datos de conductividad Solinst Levelogger 5 LTC%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/ltc-levelogger\/%22>Levelogger 5 LTC<\/a><span> <\/span>est\u00e1n disponibles en los siguientes rangos de presi\u00f3n:\n<div id=%22grey-table-wrapper%22>\n<table>\n<tbody>\n<tr>\n<td><strong>Rango de presi\u00f3n:<\/strong><\/td>\n<td><strong>Inmersi\u00f3n m\u00e1xima para alcanzar la precisi\u00f3n declarada:<\/strong><\/td>\n<\/tr>\n<tr>\n<td>M5<\/td>\n<td>5 metros (15 pies)<\/td>\n<\/tr>\n<tr>\n<td>M10<\/td>\n<td>10 metros (30 pies)<\/td>\n<\/tr>\n<tr>\n<td>M20<\/td>\n<td>20 metros (65 pies)<\/td>\n<\/tr>\n<tr>\n<td>M30<\/td>\n<td>30 metros (100 pies)<\/td>\n<\/tr>\n<tr>\n<td>M100<\/td>\n<td>100 metros (300 pies)<\/td>\n<\/tr>\n<tr>\n<td>M200<\/td>\n<td>200 metros (600 pies)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/li>\n<li>El Levelogger 5 Junior est\u00e1 disponible en rangos de presi\u00f3n M5 y M10.<\/li>\n<\/ul>\n<\/ul>\n<p>Nota: Los registradores de datos Levelogger 5 y Edge Series se pueden sobrepresurizar 2 veces (1,5 veces para los modelos Gold) el rango de inmersi\u00f3n\/calibrado indicado sin da\u00f1ar el sensor de presi\u00f3n, lo que permite una mayor flexibilidad de despliegue.<\/p>\n<ul><\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_2&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfC\u00f3mo instalo mi Levelogger en un pozo de agua subterr\u00e1nea?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>Dado que los Leveloggers est\u00e1n dise\u00f1ados para registrar las fluctuaciones del nivel del agua y de la temperatura a lo largo del tiempo (conductividad disponible con el Levelogger 5 LTC), para un rendimiento satisfactorio en una aplicaci\u00f3n de aguas subterr\u00e1neas, deben instalarse justo por debajo del nivel de agua m\u00e1s bajo previsto para ese pozo.<\/li>\n<li>Los registradores de nivel se instalan utilizando una l\u00ednea de suspensi\u00f3n o un despliegue de lectura directa. En ambas opciones de despliegue, los instrumentos se suspenden libremente, desde la parte superior del pozo hasta la profundidad deseada, mediante una l\u00ednea de suspensi\u00f3n (cable de acero inoxidable o Kevlar) o un cable de comunicaci\u00f3n de lectura directa. El cable de suspensi\u00f3n ofrece un m\u00e9todo de instalaci\u00f3n de menor coste, ideal para pozos de aguas subterr\u00e1neas poco profundas. El cable de lectura directa permite la comunicaci\u00f3n con el Levelogger desplegado en la boca del pozo.   <\/li>\n<li>Consulte la<a href=%22https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/levelogger-deployment.php%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/levelogger-deployment.php%22>Gu\u00eda de implantaci\u00f3n y comunicaci\u00f3n de Levelogger<\/a> de Solinst<span> <\/span><\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_2&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfC\u00f3mo instalo mi Levelogger en una aplicaci\u00f3n de aguas superficiales?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>Para instalaciones en r\u00edos, arroyos, humedales, lagos y control de cuencas hidrogr\u00e1ficas o de drenaje, debe considerarse el Levelogger de rango de presi\u00f3n menos profundo (M5).<\/li>\n<li>Asimismo, considere la posibilidad de utilizar los registradores de datos de nivel de agua con ventilaci\u00f3n Solinst<span> <\/span><a href=%22https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3250-levelvent\/levelvent.php%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/products\/dataloggers-and-telemetry\/3250-levelvent\/levelvent.php%22>LevelVent 5<\/a><span> <\/span>o<span> <\/span><a href=%22https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3500-aquavent\/aquavent.php%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/products\/dataloggers-and-telemetry\/3500-aquavent\/aquavent.php%22>AquaVent 5<\/a><span> <\/span>para obtener la m\u00e1xima precisi\u00f3n en aplicaciones de aguas poco profundas.<\/li>\n<li>Para la instalaci\u00f3n directa en arroyos o r\u00edos, se pueden construir pozos amortiguadores que protejan el instrumento de las turbulencias del agua. Alternativamente, los Leveloggers se pueden bajar a una tuber\u00eda o carcasa protectora y luego fijarse a un accesorio permanente, como un puente, un muelle o un marcador\/varilla accionado manualmente. <\/li>\n<li>En este tipo de aplicaciones, Solinst recomienda utilizar tambi\u00e9n un Barologger, para tener en cuenta con precisi\u00f3n las fluctuaciones de la presi\u00f3n barom\u00e9trica.<\/li>\n<li>V\u00e9anse los boletines t\u00e9cnicos:<span> <\/span><a href=%22https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/long-term-open-channel-surface-water-monitoring-with-leveloggers\/%22 title=%22Control a largo plazo de canales abiertos y aguas superficiales con Leveloggers%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/long-term-open-channel-surface-water-monitoring-with-leveloggers\/%22>Control a largo plazo de canales abiertos y aguas superficiales con registradores<\/a><a href=%22https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/absolute-vs-vented\/%22 title=%22Registradores de datos de nivel de agua absolutos vs. ventilados: \u00bfqu\u00e9 m\u00e9todo es el adecuado para su proyecto?%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/absolute-vs-vented\/%22>de<\/a>nivel<span> <\/span>y<span> <\/span>Registradores de nivel de agua absolutos frente a ventilados: \u00bfqu\u00e9 m\u00e9todo es el adecuado para su proyecto?<\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_2&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfC\u00f3mo instalo mi Barologger?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>El Barologger est\u00e1 dise\u00f1ado para registrar las fluctuaciones de la presi\u00f3n barom\u00e9trica y, por lo tanto, debe colocarse donde pueda captar los cambios en las condiciones atmosf\u00e9ricas. Para aplicaciones en aguas subterr\u00e1neas o superficiales, se recomienda suspender el Barologger en un pozo de monitorizaci\u00f3n o un pozo amortiguador por encima del nivel de agua m\u00e1s alto previsto. El Barologger debe instalarse en un entorno t\u00e9rmico similar al de los Leveloggers. Normalmente, un Barologger puede cubrir un radio de 30 km (20 millas) y\/o cada 300 m (1000 pies) de cambio de elevaci\u00f3n.   <\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_2&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfDebo utilizar el punto cero del Levelogger o medir la longitud de un cable Kevlar desplegado, una l\u00ednea de cable o un cable de lectura directa para calcular los niveles de agua?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>Medir con precisi\u00f3n la longitud del conjunto de despliegue\/cord\u00f3n puede ser problem\u00e1tico, especialmente sobre el terreno, donde no se desea que el despliegue entre en contacto con la superficie (sucia) del suelo. Adem\u00e1s, para obtener mediciones precisas y coherentes, debe asegurarse de que cada conjunto tiene la misma tensi\u00f3n medida. Si la tensi\u00f3n no es la misma, la precisi\u00f3n de la medici\u00f3n ser\u00e1 probablemente mucho menor que la del Levelogger. La medici\u00f3n de conjuntos desplegados para determinar los niveles de agua no suele ser pr\u00e1ctica ni necesaria.   <\/li>\n<li>Antes del despliegue, y antes de cada descarga de datos, Solinst recomienda medir la profundidad del agua con un medidor de nivel de agua de alta precisi\u00f3n, as\u00ed como registrar la hora del reloj. Utilizando el software Levelogger, ahora tiene la posibilidad de agregar todas sus lecturas espec\u00edficas de %22Campo Cero%22 a la hora del reloj en el Asistente de Datos, permitiendo que todas las lecturas de nivel de agua se ajusten con precisi\u00f3n a esa hora del reloj y profundidad espec\u00edficas. <\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_2&#8243;][\/dsm_faq_child][\/dsm_faq][et_pb_button button_url=\u00bbhttps:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/get-quote.php\u00bb button_text=\u00bbObtener presupuesto\u00bb admin_label=\u00bb3001 get quote\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbc9e00792-1360-4998-8cf9-5f6772c944ba\u00bb custom_margin=\u00bb20px||||false|false\u00bb custom_padding=\u00bb6px|47px|6px|47px|false|false\u00bb global_module=\u00bb62109&#8243; saved_tabs=\u00bball\u00bb global_colors_info=\u00bb{}\u00bb][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bb3676f7e6-7b83-4698-94ce-2cc9fa9ae43d\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_column_inner saved_specialty_column_type=\u00bb3_4&#8243; _builder_version=\u00bb4.27.2&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_text admin_label=\u00bbresearch article\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb hover_enabled=\u00bb0&#8243; global_colors_info=\u00bb{}\u00bb sticky_enabled=\u00bb0&#8243;]<\/p>\n<h2><strong>Supervisi\u00f3n<\/strong><\/h2>\n<p>[\/et_pb_text][dsm_faq dsm_make_accordion_toggle=\u00bbon\u00bb dsm_animate_icon=\u00bbon\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bb77be2b9f-999b-455f-afb8-d94da1ded8dc\u00bb global_colors_info=\u00bb{}\u00bb][dsm_faq_child dsm_title=\u00bb\u00bfQu\u00e9 funciones de software est\u00e1n disponibles para mis necesidades de supervisi\u00f3n?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>El<span> <\/span><a href=%22https:\/\/www.solinst.com\/instruments\/dataloggers-and-telemetry-systems\/3001-levelogger\/%22 title=%22Registradores de datos de nivel de agua Solinst Levelogger 5%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/%22>Levelogger 5<\/a><span> <\/span>y<span> <\/span><a href=%22https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/ltc-levelogger\/%22 title=%22Solinst Levelogger 5 LTC Registradores de datos de conductividad del agua%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/ltc-levelogger\/%22>Levelogger 5 LTC<\/a><span> <\/span>pueden ser programados usando Lineal, Basado en Eventos, o un Horario Personalizado.<\/li>\n<li>Lineal: se refiere a un intervalo de tiempo establecido entre la recogida de datos. La frecuencia de muestreo puede ajustarse desde 0,125 segundos hasta 99 horas. Este m\u00e9todo suele utilizarse tanto para la vigilancia a corto plazo como a largo plazo, respectivamente. La frecuencia de muestreo deseada se basa en la cantidad de datos requeridos en las especificaciones del proyecto.   <\/li>\n<li>Basado en eventos: permite al usuario definir un intervalo de muestreo (similar al modo lineal), sin embargo, el Levelogger s\u00f3lo registrar\u00e1 si el valor del par\u00e1metro ha cambiado en un umbral definido desde la \u00faltima lectura. El muestreo basado en eventos puede configurarse para cambios espec\u00edficos en el nivel del agua, la temperatura o la conductividad. Este modo de muestreo es ideal para la monitorizaci\u00f3n remota cuando s\u00f3lo deben registrarse los eventos significativos.  <\/li>\n<li>Programaci\u00f3n: permite establecer una serie de intervalos de tiempo, cada uno con su propia frecuencia de muestreo definida. Este modo de muestreo es ideal para pruebas de acu\u00edferos (slug, bombeo, recuperaci\u00f3n o paso) en las que se utiliza una frecuencia de muestreo r\u00e1pida al principio y\/o al final de la prueba para capturar la extracci\u00f3n y la recuperaci\u00f3n. La frecuencia de muestreo puede reducirse gradualmente con el tiempo (similar al muestreo logar\u00edtmico).  <\/li>\n<\/ul>\n<ul><\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_3&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfEs importante la presi\u00f3n barom\u00e9trica?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>S\u00ed. Todos los Leveloggers miden la presi\u00f3n total o absoluta. Cuando el Levelogger est\u00e1 sumergido, est\u00e1 registrando una combinaci\u00f3n de presi\u00f3n barom\u00e9trica + presi\u00f3n del agua. El nivel de agua real se obtiene eliminando los efectos de la presi\u00f3n barom\u00e9trica.  <\/li>\n<li>Solinst recomienda el uso del Barologger junto con los Leveloggers sumergibles. El software Levelogger incluye un Asistente de Datos, que gu\u00eda al usuario a trav\u00e9s del proceso automatizado de compensaci\u00f3n barom\u00e9trica de sus datos. <\/li>\n<li>V\u00e9ase el bolet\u00edn t\u00e9cnico:<span> <\/span><a href=%22https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/%22 title=%22Compensaci\u00f3n barom\u00e9trica: La importancia de los datos barom\u00e9tricos%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/%22>Compensaci\u00f3n barom\u00e9trica e importancia de los datos barom\u00e9tricos<\/a><\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_3&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfQu\u00e9 pasa si no tengo un Barologger? (C\u00f3mo realizar compensaciones barom\u00e9tricas manuales) \u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>Cuando el Levelogger est\u00e1 sumergido, est\u00e1 registrando la combinaci\u00f3n de presi\u00f3n barom\u00e9trica + presi\u00f3n del agua. Los datos meteorol\u00f3gicos recogidos localmente pueden utilizarse para corregir barom\u00e9tricamente los datos del Levelogger si no se dispone de datos de un Barologger in situ. <\/li>\n<li>V\u00e9ase el bolet\u00edn t\u00e9cnico:<span> <\/span><a href=%22https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/%22 title=%22Compensaci\u00f3n barom\u00e9trica: La importancia de los datos barom\u00e9tricos%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/%22>Compensaci\u00f3n barom\u00e9trica e importancia de los datos barom\u00e9tricos<\/a><\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_3&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfCu\u00e1ntos bar\u00f3logos necesito?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>Como regla general, un<span> <\/span><a href=%22\/?page_id=83470%22 title=%22Solinst Barologger Compensaci\u00f3n barom\u00e9trica de datos de nivel de agua%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/registradores-de-datos-de-nivel-de-agua-levelogger-5\/barologger-para-compensacion-barometrica\/%22>Barologger<\/a><span> <\/span>para un radio de 30 km (20 millas) y\/o cada 300 m (1000 pies) de cambio de elevaci\u00f3n deber\u00eda ser suficiente para captar las variaciones locales de la presi\u00f3n barom\u00e9trica.<\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_3&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfDebo tener en cuenta la altitud o la elevaci\u00f3n de mis registradores de datos desplegados?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>S\u00ed. La presi\u00f3n equivalente de la columna de agua disminuye con el aumento de la altitud a un ritmo aproximado de 1,2:1000 en la baja atm\u00f3sfera por debajo de los 5000 m (16.400 pies). Esto equivale a aproximadamente 0,5 psi por cada 1000 pies de elevaci\u00f3n (37 cm de altura de la columna de agua). <\/li>\n<li>Para los dataloggers Levelogger 5 y Edge Series, la compensaci\u00f3n se puede hacer despu\u00e9s de la recogida de datos utilizando el Asistente de Datos en el Software Levelogger Series (4.5 y superiores).<\/li>\n<li>V\u00e9ase la entrada del blog:<span> <\/span><a href=%22https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/compensating-for-altitude-in-levelogger-data\/%22 title=%22C\u00f3mo tener en cuenta la altitud al compensar los datos del Levelogger%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/compensating-for-altitude-in-levelogger-data\/%22>Contabilizaci\u00f3n de la altitud al compensar los datos del Levelogger<\/a><\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_3&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfDebo medir manualmente el nivel del agua?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>S\u00ed, Solinst recomienda encarecidamente que se realicen mediciones manuales del nivel de agua durante el periodo de monitorizaci\u00f3n. El software Levelogger permite al usuario introducir mediciones manuales del nivel del agua para poner a cero los datos con valores conocidos. Esta pr\u00e1ctica ayuda a garantizar la precisi\u00f3n de los datos y tambi\u00e9n permite al usuario cambiar el punto de referencia del conjunto de datos.  <\/li>\n<li>Si el punto de referencia o el punto de medici\u00f3n (por ejemplo, la parte superior del revestimiento del pozo) est\u00e1 por encima del nivel del agua, el campo cero (profundidad medida hasta el agua) debe introducirse como valor positivo. Si el punto de referencia est\u00e1 por debajo del nivel del agua (por ejemplo, en condiciones artesianas), se introducir\u00e1 un valor negativo. La fecha y la hora de medici\u00f3n del punto de referencia deben registrarse e introducirse para completar el ajuste.  <\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_3&#8243;][\/dsm_faq_child][\/dsm_faq][et_pb_button button_url=\u00bbhttps:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/get-quote.php\u00bb button_text=\u00bbObtener presupuesto\u00bb admin_label=\u00bb3001 get quote\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbc9e00792-1360-4998-8cf9-5f6772c944ba\u00bb custom_margin=\u00bb20px||||false|false\u00bb custom_padding=\u00bb6px|47px|6px|47px|false|false\u00bb global_module=\u00bb62109&#8243; saved_tabs=\u00bball\u00bb global_colors_info=\u00bb{}\u00bb][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bb3676f7e6-7b83-4698-94ce-2cc9fa9ae43d\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_column_inner saved_specialty_column_type=\u00bb3_4&#8243; _builder_version=\u00bb4.27.2&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_text admin_label=\u00bbresearch article\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb hover_enabled=\u00bb0&#8243; global_colors_info=\u00bb{}\u00bb sticky_enabled=\u00bb0&#8243;]<\/p>\n<h2><strong>Mantenimiento y uso adecuado del Levelogger<\/strong><\/h2>\n<ul>\n<li>V\u00e9ase el bolet\u00edn t\u00e9cnico:<span> <\/span><a href=\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/ensuring-proper-use-and-levelogger-maintenance\/\" title=\"Uso y mantenimiento adecuados de los Leveloggers Solinst\" data-uw-rm-brl=\"PR\" data-uw-original-href=\"\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/ensuring-proper-use-and-levelogger-maintenance\/\">Garantizar el uso y mantenimiento adecuados de los Leveloggers<\/a><\/li>\n<\/ul>\n<p>[\/et_pb_text][dsm_faq dsm_make_accordion_toggle=\u00bbon\u00bb dsm_animate_icon=\u00bbon\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bb77be2b9f-999b-455f-afb8-d94da1ded8dc\u00bb hover_enabled=\u00bb0&#8243; global_colors_info=\u00bb{}\u00bb sticky_enabled=\u00bb0&#8243;][dsm_faq_child dsm_title=\u00bb\u00bfQu\u00e9 ocurre si sumerjo el Levelogger a una profundidad superior a la especificada?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>Los Levelogger 5, Levelogger 5 Junior y Levelogger 5 LTC pueden soportar una sobrepresurizaci\u00f3n de 2 veces el rango especificado, por ejemplo, un modelo M10 puede soportar una fluctuaci\u00f3n de 20 metros o 60 pies y seguir registrando la presi\u00f3n sin sufrir da\u00f1os. Sin embargo, no se garantiza la precisi\u00f3n de la sobrepresi\u00f3n. <\/li>\n<\/ul>\n<ul><\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_4&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfCu\u00e1nto duran las pilas de mi Levelogger y se pueden cambiar?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>La duraci\u00f3n de la bater\u00eda del Levelogger 5 es de 10 a\u00f1os, basada en 1 lectura por minuto. Lecturas m\u00e1s r\u00e1pidas reducir\u00e1n la vida de la bater\u00eda. Por ejemplo, si un Levelogger 5 se programa en Modo Continuo a una velocidad de muestreo de 1 segundo, la bater\u00eda se agotar\u00e1 en aproximadamente 4 meses. Las bater\u00edas internas son reemplazables en f\u00e1brica.   <\/li>\n<li>Nota: El Levelogger 5 Junior tiene una duraci\u00f3n de bater\u00eda de 5 a\u00f1os basada en 1 lectura por minuto y el Levelogger 5 LTC tiene una duraci\u00f3n de bater\u00eda de 8 a\u00f1os basada en 1 lectura cada 5 minutos.<\/li>\n<li>Los cambios dr\u00e1sticos de temperatura m\u00e1s all\u00e1 de las temperaturas de funcionamiento podr\u00edan da\u00f1ar la bater\u00eda o reducir su vida \u00fatil.<\/li>\n<li>Consulte el bolet\u00edn t\u00e9cnico:<span> <\/span><a href=%22https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-levelogger-battery-life\/%22 title=%22Comprender la duraci\u00f3n de la bater\u00eda del Levelogger de Solinst%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-levelogger-battery-life\/%22>Comprender la duraci\u00f3n de la bater\u00eda del Levelogger<\/a><\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_4&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfEs necesario recalibrar la presi\u00f3n? \u00bfCu\u00e1ndo? \u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>Los Leveloggers tienen una calibraci\u00f3n de f\u00e1brica de por vida, y no requieren recalibraci\u00f3n si se utilizan en el rango especificado. La recalibraci\u00f3n puede ser necesaria si el Levelogger est\u00e1 sobrepresurizado m\u00e1s de 2 veces su rango de presi\u00f3n previsto, se utiliza en entornos inadecuados o est\u00e1 f\u00edsicamente da\u00f1ado. <\/li>\n<li>Consulte el bolet\u00edn t\u00e9cnico:<span> <\/span><a href=%22https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/%22 title=%22Exactitud, precisi\u00f3n, resoluci\u00f3n y deriva de los sensores de presi\u00f3n%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/%22>Exactitud, precisi\u00f3n, resoluci\u00f3n y deriva del sensor de presi\u00f3n<\/a><\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_4&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfSe puede reparar mi Levelogger?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>S\u00ed, los registradores de datos de la serie Levelogger 5 son totalmente reparables en Solinst. P\u00f3ngase en contacto con Solinst para conocer las opciones de servicio y los detalles de los registradores de datos de generaciones anteriores. <\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_4&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfC\u00f3mo evito que mi Levelogger se congele?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>El rango de temperatura de funcionamiento en un l\u00edquido, para el Levelogger est\u00e1 entre -20\u00b0 a 80\u00b0C (-4\u00b0 a 180\u00b0F). Para evitar la formaci\u00f3n de hielo\/congelaci\u00f3n y da\u00f1os en el transductor, el m\u00e9todo m\u00e1s sencillo es bajar el transductor a un punto de la columna de agua por debajo de la l\u00ednea de congelaci\u00f3n o de la profundidad de formaci\u00f3n de hielo. <\/li>\n<li>En masas de agua como arroyos poco profundos, humedales o estanques en los que el hielo\/congelaci\u00f3n puede penetrar hasta el fondo, instale el Levelogger en un pozo amortiguador ventilado incrustado en el fondo de la masa de agua m\u00e1s all\u00e1 de la l\u00ednea de congelaci\u00f3n.<\/li>\n<li>Si esto no es posible, coloque el Levelogger dentro de dos globos alargados de silicona, goma o l\u00e1tex llenos de una soluci\u00f3n anticongelante no t\u00f3xica y no corrosiva o de una soluci\u00f3n de agua salada. Coloque los globos en una secci\u00f3n de tuber\u00eda perforada de 30 mm (1,25%22) de di\u00e1metro interior e instale el registrador en el agua monitorizada. La soluci\u00f3n anticongelante proteger\u00e1 al Levelogger de la expansi\u00f3n del hielo en el transductor de presi\u00f3n, pero transmitir\u00e1 cualquier fluctuaci\u00f3n de presi\u00f3n y temperatura que se produzca.  <\/li>\n<li>Nota: Aunque se pueden tomar precauciones, colocar un Levelogger en una situaci\u00f3n en la que el agua pueda congelarse puede da\u00f1ar permanentemente el sensor.<\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_4&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfC\u00f3mo puedo proteger mi Levelogger de entornos corrosivos o marinos?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>El Levelogger 5 y el Levelogger 5 LTC tienen un revestimiento resistente a la corrosi\u00f3n que se hornea utilizando tecnolog\u00eda de polimerizaci\u00f3n (por dentro y por fuera). En entornos qu\u00edmicos m\u00e1s duros, puede proteger el Levelogger utilizando un globo lleno de fluido no corrosivo\/no t\u00f3xico (agua del grifo). Al cambiar la presi\u00f3n, el fluido que recubre el registrador transmitir\u00e1 la diferencia de presi\u00f3n al transductor de presi\u00f3n del registrador, sin exponerlo a condiciones corrosivas.  <\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_4&#8243;][\/dsm_faq_child][dsm_faq_child dsm_title=\u00bb\u00bfC\u00f3mo puedo limpiar mi sensor de conductividad Levelogger LTC?\u00bb dsm_content=\u00bb<\/p>\n<ul>\n<li>Las clavijas del<span> <\/span>El sensor de conductividad <a href=%22https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/ltc-levelogger\/%22 title=%22Registrador de nivel de conductividad Solinst LTC Edge%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/ltc-levelogger\/%22>LTC<span> <\/span><\/a>est\u00e1 recubierto de platino, por lo que no debe limpiarse bruscamente ni tocarse con ning\u00fan metal. Pueden limpiarse con un cepillo de cerdas suaves, un bastoncillo o un pa\u00f1o. Para limpiar el sensor se puede elegir casi cualquier soluci\u00f3n \u00e1cida, siempre que est\u00e9 muy diluida (generalmente menos del 10% de \u00e1cido). El tiempo de %22remojo%22 debe controlarse y reducirse al m\u00ednimo. Consulte el<span> <\/span><a href=%22https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/user-guide\/10-levelogger-installation-maintenance\/10-2-levelogger-maintenance.php%22 title=%22Solinst Levelogger Gu\u00eda del usuario%22 data-uw-rm-brl=%22PR%22 data-uw-original-href=%22\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/user-guide\/10-levelogger-installation-maintenance\/10-2-levelogger-maintenance.php%22>Levelogger Series Gu\u00eda del usuario<\/a><span> <\/span>para m\u00e1s recomendaciones generales de mantenimiento.<\/li>\n<\/ul>\n<p>\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb parentOrderClass=\u00bbdsm_faq_4&#8243;][\/dsm_faq_child][\/dsm_faq][et_pb_button button_url=\u00bbhttps:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/get-quote.php\u00bb button_text=\u00bbObtener presupuesto\u00bb admin_label=\u00bb3001 get quote\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbc9e00792-1360-4998-8cf9-5f6772c944ba\u00bb custom_margin=\u00bb20px||||false|false\u00bb custom_padding=\u00bb6px|47px|6px|47px|false|false\u00bb global_module=\u00bb62109&#8243; saved_tabs=\u00bball\u00bb global_colors_info=\u00bb{}\u00bb][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bb3676f7e6-7b83-4698-94ce-2cc9fa9ae43d\u00bb hover_enabled=\u00bb0&#8243; global_colors_info=\u00bb{}\u00bb sticky_enabled=\u00bb0&#8243;][et_pb_column_inner saved_specialty_column_type=\u00bb3_4&#8243; _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_text _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb hover_enabled=\u00bb0&#8243; global_colors_info=\u00bb{}\u00bb sticky_enabled=\u00bb0&#8243;]<\/p>\n<h2><strong>Entradas de blog relacionadas<\/strong><\/h2>\n<p>[\/et_pb_text][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner column_structure=\u00bb1_2,1_2&#8243; disabled_on=\u00bboff|off|off\u00bb _builder_version=\u00bb4.27.2&#8243; _module_preset=\u00bbdefault\u00bb border_width_bottom=\u00bb1px\u00bb border_color_bottom=\u00bb#d3d3d3&#8243; global_module=\u00bb62270&#8243; saved_tabs=\u00bball\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_column_inner type=\u00bb1_2&#8243; _builder_version=\u00bb4.25.0&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_image src=\u00bbhttps:\/\/www.solinst.com\/wp-content\/uploads\/2025\/02\/water-level-table-drawdown-with-cone-of-depression-500w.webp\u00bb alt=\u00bbdescenso del nivel del agua mostrando el cono de depresi\u00f3n\u00bb title_text=\u00bbDescenso del nivel del agua mostrando el cono de depresi\u00f3n\u00bb url=\u00bbhttps:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/the-importance-of-measuring-drawdown\/\u00bb force_fullwidth=\u00bbon\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb border_width_all=\u00bb1px\u00bb border_color_all=\u00bb#bcbcbc\u00bb global_colors_info=\u00bb{}\u00bb][\/et_pb_image][\/et_pb_column_inner][et_pb_column_inner type=\u00bb1_2&#8243; _builder_version=\u00bb4.25.0&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_text _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb header_2_line_height=\u00bb1.3em\u00bb link_option_url=\u00bbhttps:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/multilevel-monitoring\/extensive-groundwater-monitoring-program-at-refinery-in-australia\/\u00bb global_colors_info=\u00bb{}\u00bb]<\/p>\n<h3><strong><a href=\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/the-importance-of-measuring-drawdown\/\" title=\"La importancia de medir la reducci\u00f3n\">La importancia de medir la reducci\u00f3n<\/a><\/strong><\/h3>\n<p>C\u00f3mo utilizar un <strong>Levelogger<\/strong> y <a href=\"https:\/\/www.solinst.com\/es\/productos\/dispositivos-de-medicion-de-nivel\/101d-medidor-de-descenso-del-nivel-de-agua\/\" title=\"101D Medidor de descenso del nivel de agua\"><strong>101D Medidor de Nivel de Agua<\/strong><\/a> proporcionan datos esenciales \u00bfQu\u00e9 es la reducci\u00f3n del nivel? La reducci\u00f3n del nivel fre\u00e1tico es un cambio en el nivel de las aguas subterr\u00e1neas debido a un estr\u00e9s aplicado, causado por sucesos como: Bombeo de un pozo Bombeo de un pozo vecino Extracci\u00f3n intensiva de agua de la zona Disminuciones estacionales a medida que disminuyen las tasas de recarga \u00bfC\u00f3mo se mide la reducci\u00f3n del nivel?[\/et_pb_text][et_pb_button button_url=\u00bbhttps:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/the-importance-of-measuring-drawdown\/\u00bb button_text=\u00bbGarantizar la precisi\u00f3n de las mediciones de DrawDown\u00bb button_alignment=\u00bbright\u00bb button_alignment_tablet=\u00bbcenter\u00bb button_alignment_phone=\u00bbcenter\u00bb button_alignment_last_edited=\u00bbon|phone\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb custom_button=\u00bbon\u00bb button_text_size=\u00bb20px\u00bb button_text_color=\u00bb#000000&#8243; button_bg_color=\u00bb#FFFFFF\u00bb button_border_color=\u00bb#ff8500&#8243; button_border_radius=\u00bb20px\u00bb button_icon=\u00bb&#x3d;||divi||400&#8243; custom_padding=\u00bb0px|||||\u00bb button_text_size_tablet=\u00bb18px\u00bb button_text_size_phone=\u00bb16px\u00bb button_text_size_last_edited=\u00bbon|phone\u00bb global_colors_info=\u00bb{}\u00bb][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner _builder_version=\u00bb4.27.2&#8243; _module_preset=\u00bbdefault\u00bb custom_padding=\u00bb||1px|||\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_column_inner saved_specialty_column_type=\u00bb3_4&#8243; _builder_version=\u00bb4.27.2&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_heading title=\u00bbProductos relacionados\u00bb _builder_version=\u00bb4.27.2&#8243; _module_preset=\u00bbdefault\u00bb title_level=\u00bbh2&#8243; title_font=\u00bb|700|||||||\u00bb title_font_size=\u00bb22px\u00bb global_colors_info=\u00bb{}\u00bb][\/et_pb_heading][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner column_structure=\u00bb1_2,1_2&#8243; disabled_on=\u00bboff|off|off\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb border_width_bottom=\u00bb1px\u00bb border_color_bottom=\u00bb#d3d3d3&#8243; global_module=\u00bb62724&#8243; saved_tabs=\u00bball\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_column_inner type=\u00bb1_2&#8243; _builder_version=\u00bb4.25.0&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_image src=\u00bbhttps:\/\/www.solinst.com\/wp-content\/uploads\/2025\/02\/9500-levelsender-cellular-telemetry-system-1-500&#215;500-1.webp\u00bb alt=\u00bb9500 levelsender sistema de telemetr\u00eda celular construido para los registradores de nivel\u00bb title_text=\u00bb9500 Levelsender Sistema de Telemetr\u00eda Celular Construido Para Leveloggers\u00bb url=\u00bbhttps:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/solinst-telemetry-systems\/9500-levelsender\/levelsender.php\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb border_color_all=\u00bb#bcbcbc\u00bb global_colors_info=\u00bb{}\u00bb][\/et_pb_image][\/et_pb_column_inner][et_pb_column_inner type=\u00bb1_2&#8243; _builder_version=\u00bb4.25.0&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_text _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb header_2_line_height=\u00bb1.3em\u00bb custom_margin=\u00bb60px||||false|false\u00bb custom_margin_tablet=\u00bb0px||||false|false\u00bb custom_margin_phone=\u00bb0px||||false|false\u00bb custom_margin_last_edited=\u00bbon|desktop\u00bb link_option_url=\u00bbhttps:\/\/www.solinst.com\/products\/enhanced-biodegradation\/703-waterloo-emitters\/index.php\u00bb global_colors_info=\u00bb{}\u00bb]<\/p>\n<h2><strong><a href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/solinst-telemetry-systems\/9500-levelsender\/levelsender.php\" data-uw-rm-brl=\"PR\" data-uw-original-href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/solinst-telemetry-systems\/9500-levelsender\/levelsender.php\">Telemetr\u00eda Plug and Play<\/a><\/strong><\/h2>\n<p><span>\u00bfYa tienes Leveloggers? Actualiza r\u00e1pida y f\u00e1cilmente tus pozos de monitorizaci\u00f3n con LevelSender Telemetr\u00eda.  En  <\/span><a href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/solinst-telemetry-systems\/9500-levelsender\/levelsender.php\" title=\"Sistema de telemetr\u00eda Solinst LevelSender 4G con tarjeta SIM incorporada\" data-uw-rm-brl=\"PR\" data-uw-original-href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/solinst-telemetry-systems\/9500-levelsender\/levelsender.php\"><strong>El sistema de telemetr\u00eda 4G LevelSender 5 incorpora una tarjeta SIM Solinst opcional<\/strong><\/a><span>. Se configura por ti de antemano, con un plan de bajo coste gestionado por Solinst. Un bar\u00f3metro interno proporciona lecturas del nivel de agua compensadas autom\u00e1ticamente; configura alarmas de nivel alto\/bajo. <\/span><\/p>\n<p>[\/et_pb_text][et_pb_button button_url=\u00bbhttps:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/solinst-telemetry-systems\/9500-levelsender\/levelsender.php\u00bb button_text=\u00bbTelemetr\u00eda celular simplificada\u00bb button_alignment=\u00bbright\u00bb button_alignment_tablet=\u00bbcenter\u00bb button_alignment_phone=\u00bbcenter\u00bb button_alignment_last_edited=\u00bbon|phone\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb custom_button=\u00bbon\u00bb button_text_color=\u00bb#000000&#8243; button_bg_color=\u00bb#FFFFFF\u00bb button_border_color=\u00bb#ff8500&#8243; button_border_radius=\u00bb20px\u00bb button_icon=\u00bb&#x3d;||divi||400&#8243; custom_padding=\u00bb0px|||||\u00bb button_text_size_tablet=\u00bb18px\u00bb button_text_size_phone=\u00bb16px\u00bb button_text_size_last_edited=\u00bbon|phone\u00bb global_colors_info=\u00bb{}\u00bb][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner column_structure=\u00bb1_2,1_2&#8243; disabled_on=\u00bboff|off|off\u00bb _builder_version=\u00bb4.27.2&#8243; _module_preset=\u00bbdefault\u00bb border_width_bottom=\u00bb1px\u00bb border_color_bottom=\u00bb#d3d3d3&#8243; global_module=\u00bb62677&#8243; saved_tabs=\u00bball\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_column_inner type=\u00bb1_2&#8243; _builder_version=\u00bb4.25.0&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_image src=\u00bbhttps:\/\/www.solinst.com\/wp-content\/uploads\/2025\/02\/9700-solsat-5-satellite-telemetry-system-1-500&#215;500-1.webp\u00bb alt=\u00bbmodelo 9700 solar 5 sistema de telemetr\u00eda por sat\u00e9lite descubre la vigilancia en cualquier lugar\u00bb title_text=\u00bbSistema de Telemetr\u00eda por Sat\u00e9lite Modelo 9700 Solar 5 Descubre la Monitorizaci\u00f3n en Cualquier Lugar\u00bb url=\u00bbhttps:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/solinst-telemetry-systems\/9700-solsat\/solsat.php\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb border_color_all=\u00bb#bcbcbc\u00bb global_colors_info=\u00bb{}\u00bb][\/et_pb_image][\/et_pb_column_inner][et_pb_column_inner type=\u00bb1_2&#8243; _builder_version=\u00bb4.25.0&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_text _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb header_2_line_height=\u00bb1.3em\u00bb custom_margin=\u00bb60px||||false|false\u00bb custom_margin_tablet=\u00bb0px||||false|false\u00bb custom_margin_phone=\u00bb0px||||false|false\u00bb custom_margin_last_edited=\u00bbon|desktop\u00bb link_option_url=\u00bbhttps:\/\/www.solinst.com\/products\/enhanced-biodegradation\/703-waterloo-emitters\/index.php\u00bb global_colors_info=\u00bb{}\u00bb]<\/p>\n<h2><strong><a href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/solinst-telemetry-systems\/9700-solsat\/solsat.php\" title=\"Sistema de telemetr\u00eda SolSat 5\" data-uw-rm-brl=\"PR\" data-uw-original-href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/solinst-telemetry-systems\/9700-solsat\/solsat.php\">Descubre la monitorizaci\u00f3n en cualquier lugar<\/a><\/strong><\/h2>\n<p><a href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/solinst-telemetry-systems\/9700-solsat\/solsat.php\" data-uw-rm-brl=\"PR\" data-uw-original-href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/solinst-telemetry-systems\/9700-solsat\/solsat.php\"><strong>SolSat 5<\/strong><\/a><span>  es un sistema de telemetr\u00eda que aprovecha la tecnolog\u00eda por sat\u00e9lite Iridium para proporcionar conectividad global a los registradores de datos Solinst Serie 5. Utiliza la mensajer\u00eda global por sat\u00e9lite TextAnywhere de bajo coste para enviar datos remotos a un portal web seguro. Cuenta con una robusta carcasa resistente a la intemperie para instalarlo pr\u00e1cticamente en cualquier lugar.  Incorpora aplicaci\u00f3n de configuraci\u00f3n Wi-Fi, panel solar y bar\u00f3metro.  <\/span><\/p>\n<p>[\/et_pb_text][et_pb_button button_url=\u00bbhttps:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/solinst-telemetry-systems\/9700-solsat\/solsat.php\u00bb button_text=\u00bbTelemetr\u00eda por sat\u00e9lite\u00bb button_alignment=\u00bbright\u00bb button_alignment_tablet=\u00bbcenter\u00bb button_alignment_phone=\u00bbcenter\u00bb button_alignment_last_edited=\u00bbon|phone\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb custom_button=\u00bbon\u00bb button_text_color=\u00bb#000000&#8243; button_bg_color=\u00bb#FFFFFF\u00bb button_border_color=\u00bb#ff8500&#8243; button_border_radius=\u00bb20px\u00bb button_icon=\u00bb&#x3d;||divi||400&#8243; custom_padding=\u00bb0px|||||\u00bb button_text_size_tablet=\u00bb18px\u00bb button_text_size_phone=\u00bb16px\u00bb button_text_size_last_edited=\u00bbon|phone\u00bb global_colors_info=\u00bb{}\u00bb][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner column_structure=\u00bb1_2,1_2&#8243; disabled_on=\u00bboff|off|off\u00bb _builder_version=\u00bb4.27.2&#8243; _module_preset=\u00bbdefault\u00bb border_width_bottom=\u00bb1px\u00bb border_color_bottom=\u00bb#d3d3d3&#8243; global_module=\u00bb62709&#8243; saved_tabs=\u00bball\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_column_inner type=\u00bb1_2&#8243; _builder_version=\u00bb4.25.0&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_image src=\u00bbhttps:\/\/www.solinst.com\/wp-content\/uploads\/2025\/02\/4001-sru-solinst-readout-unit-1-500&#215;500-1.webp\u00bb alt=\u00bb4001 sru unidad de lectura de solinst para el acceso instant\u00e1neo a los datos del registrador de nivel en tiempo real\u00bb title_text=\u00bb4001 SRU Unidad de Lectura Solinst Para el Acceso Instant\u00e1neo a los Datos del Registrador de Nivel en Tiempo Real\u00bb url=\u00bbhttps:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/4001\/4001-sru\/sru.php\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb border_color_all=\u00bb#bcbcbc\u00bb global_colors_info=\u00bb{}\u00bb][\/et_pb_image][\/et_pb_column_inner][et_pb_column_inner type=\u00bb1_2&#8243; _builder_version=\u00bb4.25.0&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_text _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb header_2_line_height=\u00bb1.3em\u00bb custom_margin=\u00bb60px||||false|false\u00bb custom_margin_tablet=\u00bb0px||||false|false\u00bb custom_margin_phone=\u00bb0px||||false|false\u00bb custom_margin_last_edited=\u00bbon|desktop\u00bb link_option_url=\u00bbhttps:\/\/www.solinst.com\/products\/enhanced-biodegradation\/703-waterloo-emitters\/index.php\u00bb global_colors_info=\u00bb{}\u00bb]<\/p>\n<h2><strong><a href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/4001\/4001-sru\/sru.php\" title=\"La unidad de lectura Solinst proporciona acceso instant\u00e1neo a los datos del nivel de agua compensado\" data-uw-rm-brl=\"PR\" data-uw-original-href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/4001\/4001-sru\/sru.php\">Unidad de Lectura Solinst (SRU)<\/a><\/strong><\/h2>\n<p><span>La <\/span><strong><a href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/4001\/4001-sru\/sru.php\" data-uw-rm-brl=\"PR\" data-uw-original-href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/4001\/4001-sru\/sru.php\">Unidad de Lectura Solinst (SRU)<\/a><\/strong><span>  es un robusto dispositivo port\u00e1til dise\u00f1ado para conectarse a un registrador de datos Solinst desplegado y mostrar lecturas instant\u00e1neas del nivel del agua, con la opci\u00f3n de compensaci\u00f3n barom\u00e9trica autom\u00e1tica. El registro en tiempo real y los datos descargados pueden guardarse y transferirse a un PC. Comprueba r\u00e1pidamente el estado del datalogger.  <\/span><\/p>\n<p>[\/et_pb_text][et_pb_button button_url=\u00bbhttps:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/4001\/4001-sru\/sru.php\u00bb button_text=\u00bbAcceso a los datos en tiempo real\u00bb button_alignment=\u00bbright\u00bb button_alignment_tablet=\u00bbcenter\u00bb button_alignment_phone=\u00bbcenter\u00bb button_alignment_last_edited=\u00bbon|phone\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb custom_button=\u00bbon\u00bb button_text_color=\u00bb#000000&#8243; button_bg_color=\u00bb#FFFFFF\u00bb button_border_color=\u00bb#ff8500&#8243; button_border_radius=\u00bb20px\u00bb button_icon=\u00bb&#x3d;||divi||400&#8243; custom_padding=\u00bb0px|||||\u00bb button_text_size_tablet=\u00bb18px\u00bb button_text_size_phone=\u00bb16px\u00bb button_text_size_last_edited=\u00bbon|phone\u00bb global_colors_info=\u00bb{}\u00bb][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner column_structure=\u00bb1_2,1_2&#8243; disabled_on=\u00bboff|off|off\u00bb _builder_version=\u00bb4.27.2&#8243; _module_preset=\u00bbdefault\u00bb border_width_bottom=\u00bb1px\u00bb border_color_bottom=\u00bb#d3d3d3&#8243; global_module=\u00bb62564&#8243; saved_tabs=\u00bball\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_column_inner type=\u00bb1_2&#8243; _builder_version=\u00bb4.25.0&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_image src=\u00bbhttps:\/\/www.solinst.com\/wp-content\/uploads\/2025\/02\/301-water-level-temperature-sensor-1-500&#215;500-1.webp\u00bb alt=\u00bbsolinst modelo 301 sensor de temperatura de nivel de agua transmisor sumergible de nivel de agua\u00bb title_text=\u00bbSensor de temperatura de nivel de agua Solinst Modelo 301 Transmisor sumergible de nivel de agua\u00bb url=\u00bbhttps:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/301-water-level-temp-sensor\/water-level-temp-sensor.php\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb border_color_all=\u00bb#bcbcbc\u00bb global_colors_info=\u00bb{}\u00bb][\/et_pb_image][\/et_pb_column_inner][et_pb_column_inner type=\u00bb1_2&#8243; _builder_version=\u00bb4.25.0&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_text _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb header_2_line_height=\u00bb1.3em\u00bb custom_margin=\u00bb60px||||false|false\u00bb custom_margin_tablet=\u00bb0px||||false|false\u00bb custom_margin_phone=\u00bb0px||||false|false\u00bb custom_margin_last_edited=\u00bbon|desktop\u00bb link_option_url=\u00bbhttps:\/\/www.solinst.com\/products\/enhanced-biodegradation\/703-waterloo-emitters\/index.php\u00bb global_colors_info=\u00bb{}\u00bb]<\/p>\n<h2><strong><a href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/301-water-level-temp-sensor\/water-level-temp-sensor.php\" title=\"301 Sensor de temperatura del nivel de agua\" data-uw-rm-brl=\"PR\" data-uw-original-href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/301-water-level-temp-sensor\/water-level-temp-sensor.php\">Transmisor de nivel de agua sumergible vers\u00e1til<\/a><\/strong><\/h2>\n<p><span>El<\/span><strong><a href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/301-water-level-temp-sensor\/water-level-temp-sensor.php\" data-uw-rm-brl=\"PR\" data-uw-original-href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/301-water-level-temp-sensor\/water-level-temp-sensor.php\" title=\" 301 Sensor de temperatura del nivel de agua\"> 301 Sensor de temperatura del nivel de agua<\/a><\/strong><span>  ofrece la opci\u00f3n de transmisi\u00f3n de nivel de agua de gran precisi\u00f3n mediante m\u00faltiples protocolos -MODBUS, SDI-12 y 4-20 mA- para una amplia variedad de aplicaciones. Este transmisor de nivel hidrost\u00e1tico sumergible, compacto y todo en uno, proporciona lecturas continuas y estables del nivel de agua y la temperatura, con opciones para sensores de presi\u00f3n absoluta y manom\u00e9trica. <\/span><\/p>\n<p>[\/et_pb_text][et_pb_button button_url=\u00bbhttps:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/levelogger\/\u00bb button_text=\u00bbSensor de temperatura del nivel de agua\u00bb button_alignment=\u00bbright\u00bb button_alignment_tablet=\u00bbcenter\u00bb button_alignment_phone=\u00bbcenter\u00bb button_alignment_last_edited=\u00bbon|phone\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb custom_button=\u00bbon\u00bb button_text_color=\u00bb#000000&#8243; button_bg_color=\u00bb#FFFFFF\u00bb button_border_color=\u00bb#ff8500&#8243; button_border_radius=\u00bb20px\u00bb button_icon=\u00bb&#x3d;||divi||400&#8243; custom_padding=\u00bb0px|||||\u00bb button_text_size_tablet=\u00bb18px\u00bb button_text_size_phone=\u00bb16px\u00bb button_text_size_last_edited=\u00bbon|phone\u00bb global_colors_info=\u00bb{}\u00bb][\/et_pb_button][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_column_inner saved_specialty_column_type=\u00bb3_4&#8243; _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_code _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb]<script type=\"application\/ld+json\"><!-- [et_pb_line_break_holder] -->{<!-- [et_pb_line_break_holder] -->  \"@context\": \"https:\/\/schema.org\",<!-- [et_pb_line_break_holder] -->  \"@type\": \"FAQPage\",<!-- [et_pb_line_break_holder] -->  \"mainEntity\": [{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"What is the difference between a Levelogger and Barologger?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"Leveloggers record changes in absolute pressure (water column pressure + barometric pressure) with time. The Barologger functions and communicates similarly to the Levelogger, but is used above the water level to record ambient barometric pressure in order to barometrically correct data recorded by the Leveloggers. Typically one Barologger can cover a radius of 30 km (20 miles) and\/or every 300 m (1000 ft) elevation change. See Technical Bulletin: Barometric Compensation and the Importance of Barometric Data.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"What is the difference between absolute and vented (gauged) pressure sensors?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"See Technical Bulletin: Absolute Vs Vented Water Level Dataloggers \u2013 Which Method Is Right For Your Project?\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"How do I select the correct pressure range of Levelogger for my application?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"The choice of pressure range largely depends on the accuracy of the water level required and the desired submergence depth. The selection, however, should be based on the maximum anticipated water level fluctuation.<!-- [et_pb_line_break_holder] -->Example: The Levelogger 5 M5 is designed for 5 meters or 15 feet submergence and provides a typical water level accuracy of \u00b13 mm (0.01 ft). This instrument is ideally suited for surface water and shallow groundwater applications, where precise water level measurements are essential.<!-- [et_pb_line_break_holder] -->If, however, the anticipated water level fluctuation will be greater than the designed range, then the next available range should be chosen for that application.<!-- [et_pb_line_break_holder] -->Example: 10 meters (30 feet) water level fluctuation is expected. To protect from possible over-ranging, the next available pressure range instrument (Levelogger 5 M20) should be selected.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"How do I know that I'm using the most current version of software and firmware?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"The most current Levelogger software and firmware versions are available on the Solinst website Downloads page. You can check from time-to-time to see if you have the most current version, or by registering your software when you download it, you will receive automatic email messages notifying you when new software or firmware becomes available.<!-- [et_pb_line_break_holder] -->In addition, when using Levelogger Software Version (4.0.1 and up) on a computer with an Internet connection, automatic notifications will be provided when new software and firmware releases are available. Clicking on the notification message will take you right to the software\/firmware download page.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"Do I have to pay for software and firmware?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"No, all current software and firmware versions are available to download free from the Solinst website. If you register your software when you download it, you will receive automatic notices when new software or firmware has been released.<!-- [et_pb_line_break_holder] -->See Solinst Downloads page.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"How do I update the software?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"Download new software versions free from the Solinst website as they become available.<!-- [et_pb_line_break_holder] -->See Solinst Downloads page.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"How do I update Levelogger firmware?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"Levelogger software comes equipped with a \\\"Firmware Upgrade Utility\\\". As new firmware versions become available they can be downloaded free from the Solinst website and uploaded to your Levelogger using the Utility. Ensure the software is the latest version, as it contains the most recent Firmware Upgrade Utility.<!-- [et_pb_line_break_holder] -->See Solinst Downloads page.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"What types of applications are Leveloggers suited for?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"Leveloggers are suited for the following applications:<!-- [et_pb_line_break_holder] -->Long-term groundwater monitoring<!-- [et_pb_line_break_holder] -->River, lake, stream gauging<!-- [et_pb_line_break_holder] -->Water resource management<!-- [et_pb_line_break_holder] -->Aquifer tests \u2013 pumping, slug, step, recovery<!-- [et_pb_line_break_holder] -->Remote monitoring with telemetry applications<!-- [et_pb_line_break_holder] -->Harbor and tidal fluctuation and wave action monitoring<!-- [et_pb_line_break_holder] -->Industrial tank level monitoring<!-- [et_pb_line_break_holder] -->Management of water taking\/pumping<!-- [et_pb_line_break_holder] -->Watershed or drainage basin recharge studies<!-- [et_pb_line_break_holder] -->Wetlands and storm water runoff monitoring<!-- [et_pb_line_break_holder] -->Long-term water level monitoring in wells<!-- [et_pb_line_break_holder] -->Dam, reservoir, lock monitoring<!-- [et_pb_line_break_holder] -->Combined Sewer Overflow (CSO) and storm water management<!-- [et_pb_line_break_holder] -->Dewatering projects<!-- [et_pb_line_break_holder] -->Aquifer storage and recovery observation<!-- [et_pb_line_break_holder] -->Salt water intrusion and soil salination monitoring<!-- [et_pb_line_break_holder] -->Plume remediation monitoring and studies<!-- [et_pb_line_break_holder] -->Leachate monitoring at landfills, mine tailings, wastes disposal storage sites<!-- [et_pb_line_break_holder] -->PFAS monitoring applications<!-- [et_pb_line_break_holder] -->Tracer tests<!-- [et_pb_line_break_holder] -->Agricultural and stormwater runoff monitoring<!-- [et_pb_line_break_holder] -->And more...\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"Can the Levelogger be used for continuous groundwater monitoring?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"Yes, Leveloggers are self-contained dataloggers designed to continuously record water level and temperature fluctuations over time. Leveloggers are available in a number of different pressure ranges, which can be used for shallow piezometers to deep pumping well monitoring. The Solinst Levelogger software package includes features that allow you to incorporate manual water level field measurements; conduct barometric compensations; or adjust the data relative to another reference point (depth to water, ground surface elevation, etc.).<!-- [et_pb_line_break_holder] -->Remote monitoring via telemetry is also an option.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"Can the Levelogger be used in pumping tests?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"Yes, Leveloggers are excellent to use during all pumping tests. The Levelogger 5 and Levelogger 5 LTC can be programmed with a customized sampling schedule that sets the rates at which water level data is collected for a number of separate intervals. You can customize different sampling rates and durations to record water level readings before, during and after the pumping test (baseline, pumping and recovery). If deployed on a direct read cable, real-time Levelogger readings can be viewed and saved on a laptop computer or smart device during the pumping test.<!-- [et_pb_line_break_holder] -->See Technical Bulletin: Simplify Your Pumping Test...Use a Water Level Datalogger.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"Can I place a Levelogger beside an electric down hole pump?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"Yes, due to the Faraday cage design, all of the data recorded internally by the Levelogger will be unaffected from nearby electrical noise. Ideally, however, when deploying a Levelogger in a well with a pump, the Levelogger should be placed beyond any potential interference\/turbulence effects from the pump's intake. If a Direct Read Cable is used, a separate insertion pipe, that is grounded, is also recommended to prevent potential electrical interference with communication when collecting or viewing data running in Real-Time mode. In the absence of a grounded insertion pipe, ensure the pump is shutoff before interfacing through the Direct Read Cable.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"Are Leveloggers suited for surface water applications?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"Yes, the M5 Levelogger 5, Levelogger 5 Junior and Levelogger 5 LTC instruments utilize a highly sensitive pressure sensor for precise water level accuracy and resolution, ideally suited for surface water applications (lakes, wetland, watershed, river or stream gauging). The Levelogger 5 M5 used in tandem with a Barologger 5 can attain water level accuracies of \u00b18 mm\/ 0.017 ft.<!-- [et_pb_line_break_holder] -->Also, consider using the Solinst LevelVent 5 or AquaVent 5 vented water level dataloggers for highest accuracy in shallow water applications.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"Can Leveloggers be used in saltwater environments?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"Yes, the Levelogger 5, Levelogger 5 Junior, and Levelogger 5 LTC can be used in short-term to long-term monitoring in salt water or brackish environments. The Levelogger 5 and Levelogger 5 LTC have a corrosion-resistant coating. However, in harsher environments, you can protect the Levelogger 5 Junior using a balloon filled with non-corrosive\/ non-toxic fluid (tap water). As pressure changes, the fluid encasing the loggers will transmit the pressure differential to the logger's pressure transducer, without exposing it to corrosive conditions. Refer to the Levelogger Series User Guide for further maintenance recommendations.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"Can I use the same Levelogger in a shallow stream and then in a deep water well?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"Yes, but as with any pressure sensor, be aware that when selecting a higher range sensor (e.g. M100) it provides less accuracy than a lower range sensor (e.g. M5). Choose a pressure range that best meets the needs of your monitoring program (without submerging beyond the calibrated range).\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"Can I use Solinst Leveloggers in my PFAS monitoring project?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"Yes, PFAS is not used or knowingly present in the manufacture or production of Solinst Products. The wetted materials for the Levelogger 5 are: corrosion-resistant PTFE coating baked-on using polymerization technology, acetal\/Delrin\u00ae nose cone, filter and top cap, 316L SS, Hastelloy pressure sensor, and a Viton\u00ae o-ring. The Levelogger 5 LTC also includes: An acetal conductivity cell and Platinum clad Niobium core wires.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"Can I use Solinst Leveloggers in groundwater with a pH of 4?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"As recommended with all our Products, before starting any environmental monitoring project, it is essential to take some steps to evaluate whether the equipment you choose will work as expected in your specific monitoring location. This means comparing the wetted materials of your Levelogger with the conditions and chemicals you expect to encounter in you monitoring project \u2013 including pH.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"How deep can I install my Levelogger?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"The depth of submergence for the Levelogger (at the highest expected water level) is based on the specified pressure range for the instrument. The Levelogger 5 and Levelogger 5 LTC are available in the following pressure ranges:<!-- [et_pb_line_break_holder] -->Pressure Range:\tMaximum Submergence to Achieve Stated Accuracy:<!-- [et_pb_line_break_holder] -->M5\t5 meters (15 feet)<!-- [et_pb_line_break_holder] -->M10\t10 meters (30 feet)<!-- [et_pb_line_break_holder] -->M20\t20 meters (65 feet)<!-- [et_pb_line_break_holder] -->M30\t30 meters (100 feet)<!-- [et_pb_line_break_holder] -->M100\t100 meters (300 feet)<!-- [et_pb_line_break_holder] -->M200\t200 meters (600 feet)<!-- [et_pb_line_break_holder] -->The Levelogger 5 Junior is available in M5 and M10 pressure ranges.<!-- [et_pb_line_break_holder] -->Note: Levelogger 5 and Edge Series dataloggers can be over-pressurized 2 times (1.5 times for Gold Models) the stated submergence\/calibrated range without damage to the pressure sensor, allowing for deployment flexibility.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"How do I install my Levelogger in a groundwater well?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"Since Leveloggers are designed to record water level and temperature fluctuations over time (conductivity available with Levelogger 5 LTC), for successful performance in a groundwater application, they should be installed just below the lowest expected water level for that well.<!-- [et_pb_line_break_holder] -->Leveloggers are installed by using either a suspension line or direct read deployment. In both deployment options the instruments are freely suspended, from the top of the well to the desired depth, via a support line (stainless steel or Kevlar cord) or a direct read communication cable. The suspension wire offers a lower-cost installation method that is ideal for shallow groundwater wells. The Direct Read Cable enables communication with the deployed Levelogger at the well head.<!-- [et_pb_line_break_holder] -->See the Solinst Levelogger Deployment and Communication Guide.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"How do I install my Levelogger in a surface water application?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"For installations within rivers, streams, wetlands, lakes and watershed or drainage basin monitoring, the shallowest pressure range Levelogger (M5) should be considered.<!-- [et_pb_line_break_holder] -->Also, consider using the Solinst LevelVent 5 or AquaVent 5 vented water level dataloggers for highest accuracy in shallow water applications.<!-- [et_pb_line_break_holder] -->For direct installation in streams or rivers, stilling wells can be constructed which shield the instrument from the water turbulence. Alternatively, Leveloggers can be lowered into a protective pipe or casing and then attached to a permanent fixture such as a bridge, pier or hand driven marker\/rod.<!-- [et_pb_line_break_holder] -->In these types of applications, Solinst recommends that a Barologger also be used, to accurately account for barometric pressure fluctuations.<!-- [et_pb_line_break_holder] -->See Technical Bulletins: Long-term Open Channel and Surface Water Monitoring with Leveloggers and Absolute Vs Vented Water Level Dataloggers \u2013 Which Method Is Right For Your Project?\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"How do I install my Barologger?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"The Barologger is designed to record barometric pressure fluctuations, and hence should be placed where it can capture changes in atmospheric conditions. For groundwater or surface water applications, it is recommended that the Barologger be suspended in a monitoring well or stilling well above the highest expected water level. The Barologger should be installed in a similar thermal environment to that of the Leveloggers. Typically one Barologger can cover a radius of 30 km (20 mile) and\/or every 300 m (1000 ft) elevation change.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"Should I use the Zero Point of the Levelogger, or measure the length of a deployed Kevlar Cord, Wire Line, or Direct Read Cable to calculate water levels?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"Accurately measuring the length of the deployment assembly\/ cord, can be problematic\u2014especially in the field, where you don't want the deployment to come in contact with the (dirty) ground surface. Also, to achieve consistent accurate measurements, you would need to ensure that you have the same amount of measured tension on each assembly. Without having a consistent amount of pulled tension, your measured accuracy will likely be much less than that of the Levelogger. Measuring deployed assemblies to determine water levels, is typically not practical, nor needed.<!-- [et_pb_line_break_holder] -->Before deployment, and before each data download, Solinst recommends measuring the depth to water with a highly accurate water level meter, as well as recording the clock time. Using the Levelogger Software, you now have the ability to add all of your specific clock time \\\"Field Zero\\\" readings into the Data Wizard, allowing all water level readings to be accurately adjusted to that specific clock time and depth.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"What software features are available for my monitoring needs?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"The Levelogger 5 and Levelogger 5 LTC can be programmed using Linear, Event-based, or a Customized Schedule.<!-- [et_pb_line_break_holder] -->Linear: refers to a set time interval between data collection. The sample rate can be set as fast as 0.125 seconds to 99 hours. This method is commonly used for both short term and long term monitoring, respectively. The desired sampling rate is based on how much data is required in the project specifications.<!-- [et_pb_line_break_holder] -->Event-based: allows the user to define a sampling interval (similar to the linear mode) however, the Levelogger will only record if the parameter value has changed by a defined threshold from the last reading. Event-based sampling can be set for specific changes in water level, temperature, or conductivity. This sampling mode is ideal for remote monitoring when only significant events are to be recorded.<!-- [et_pb_line_break_holder] -->Schedule: allows you to set a number of time intervals, each with its own defined sampling rate. This sampling mode is ideal for aquifer tests (slug, pumping, recovery or step) where a fast sampling rate is used at the beginning and\/or end of the test to capture the draw-down and recovery. The sampling rate can be gradually decreased over time (similar to logarithmic sampling).\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"Is barometric pressure important?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"Yes. All Leveloggers measure total or absolute pressure. When the Levelogger is submerged, it is recording a combination of barometric pressure + water pressure. The actual water level is obtained by removing barometric pressure effects.<!-- [et_pb_line_break_holder] -->Solinst recommends the use of the Barologger in tandem with the submersible Leveloggers. The Levelogger software includes a Data Wizard, which guides the user through the automated process of barometric compensation of their data.<!-- [et_pb_line_break_holder] -->See Technical Bulletin: Barometric Compensation and the Importance of Barometric Data.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"What if I do not have a Barologger? (How to conduct manual barometric compensations)\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"When the Levelogger is submerged, it is recording the combination of barometric pressure + water pressure. Locally collected weather data can be used to barometrically correct the Levelogger data if data from an on-site Barologger is not available.<!-- [et_pb_line_break_holder] -->See Technical Bulletin: Barometric Compensation and the Importance of Barometric Data.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"How many Barologgers do I need?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"As a rule of thumb, one Barologger for a 30 km (20 mile) radius and\/or every 300 m (1000 ft) change in elevation should be sufficient to capture local variations in barometric pressure.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"Should I consider the altitude or elevation of my deployed dataloggers?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"Yes. Water column equivalent pressure decreases with an increase in altitude at a rate of approximately 1.2:1000 in the lower atmosphere below 5000 m (16,400 ft). This equates to about 0.5 psi per 1000 ft increase in elevation (37 cm of water column height).<!-- [et_pb_line_break_holder] -->For the Levelogger 5 and Edge Series dataloggers, compensation can be done post data collection using the Data Wizard in the Levelogger Series Software (4.5 and up).<!-- [et_pb_line_break_holder] -->See Blog Post: Accounting For Altitude When Compensating Levelogger Data.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"Should I take manual water level measurements?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"Yes, Solinst strongly recommends that manual water level measurements be taken during the monitoring period. The Levelogger software allows the user to enter manual water level measurements to field zero the data with known values. This practice helps to ensure the accuracy of the data and also allows the user to change the datum reference point for the data set.<!-- [et_pb_line_break_holder] -->If the reference datum or measuring point (e.g. top of well casing) is above water level, the field zero (measure depth to water) must be input as a positive value. If the reference datum is below water level (e.g. artesian condition), a negative value is input. The date and time of measurement of the reference datum must be recorded and input to complete the adjustment.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"What if I submerge my Levelogger deeper than the specified range?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"The Levelogger 5, Levelogger 5 Junior and Levelogger 5 LTC can withstand over-pressurization of 2 times the specified range, e.g. a Model M10 can accommodate a fluctuation of 20 meters or 60 feet and still record pressure without damage. However, over-range accuracy is not guaranteed.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"How long will the batteries in my Levelogger last and are they replaceable?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"The Battery life of the Levelogger 5 is 10 years, based on 1 reading per minute. Readings that are more rapid will reduce the battery life. For example, if a Levelogger 5 is programmed in Continuous Mode at a sampling rate of 1 second, the battery will be depleted in approximately 4 months. The internal batteries are factory replaceable.<!-- [et_pb_line_break_holder] -->Note: The Levelogger 5 Junior has a battery life of 5 years based on 1 reading per minute and Levelogger 5 LTC has a battery life of 8 years based on 1 reading every 5 minutes.<!-- [et_pb_line_break_holder] -->Drastic temperature changes beyond operating temperatures might cause battery damage or reduced battery life.<!-- [et_pb_line_break_holder] -->See Technical Bulletin: Understanding Levelogger Battery Life.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"Is pressure recalibration necessary? When?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"Leveloggers have a lifetime factory calibration, and do not require recalibration if used in the specified range. Recalibration may be required if the Levelogger is over-pressurized by more than 2 times their intended pressure range, used in unsuitable environments, or physically damaged.<!-- [et_pb_line_break_holder] -->See Technical Bulletin: Understanding Pressure Sensor Accuracy, Precision, Resolution & Drift.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"Is my Levelogger repairable?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"Yes, Levelogger 5 Series dataloggers are fully serviceable at Solinst. Please contact Solinst for service options and details for older generation dataloggers.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"How do I protect my Levelogger from freezing?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"The operating temperature range in a liquid, for the Levelogger is between -20\u00b0 to 80\u00b0C (-4\u00b0 to 180\u00b0F). To avoid icing\/ freezing and transducer damage, the easiest method is to lower the transducer to a point in the water column below the frost line or ice formation depth.<!-- [et_pb_line_break_holder] -->In water bodies such as shallow streams, wetlands or ponds where icing\/freezing may penetrate to the bottom, install the Levelogger in a vented stilling well imbedded into the bottom of the water body beyond the frost line.<!-- [et_pb_line_break_holder] -->If this is not possible, place the Levelogger inside two elongated silicon, rubber or latex balloons filled with a non-toxic, non-corrosive anti-freeze solution or saltwater solution. Place the balloons in a section of perforated, 30 mm (1.25\\\") ID pipe and install the logger in the monitored water. The antifreeze solution will protect the Levelogger from ice expansion at the pressure transducer, yet transmit any pressure and temperature fluctuations that occur.<!-- [et_pb_line_break_holder] -->Note: Although precautions can be taken, placing a Levelogger in a situation where the water may freeze solid can permanently damage the sensor.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"How can I protect my Levelogger from corrosive or marine environments?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"The Levelogger 5 and Levelogger 5 LTC have a corrosion-resistant coating that is baked-on using polymerization technology (inside and out). In harsher chemical environments, you can protect the Levelogger using a balloon filled with non-corrosive\/non-toxic fluid (tap water). As pressure changes, the fluid encasing the logger will transmit the pressure differential to the logger's pressure transducer, without exposing it to corrosive conditions.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  },{<!-- [et_pb_line_break_holder] -->    \"@type\": \"Question\",<!-- [et_pb_line_break_holder] -->    \"name\": \"How can I clean my Levelogger LTC Conductivity Sensor?\",<!-- [et_pb_line_break_holder] -->    \"acceptedAnswer\": {<!-- [et_pb_line_break_holder] -->      \"@type\": \"Answer\",<!-- [et_pb_line_break_holder] -->      \"text\": \"The pins of the LTC conductivity sensor are platinum-coated, therefore they should not be roughly cleaned or touched with any metal. They can be cleaned with a soft bristle brush, Q-tip, or cloth. Almost any acid solution can be selected to clean the sensor, provided it is highly diluted (generally less than 10% acid). The \\\"soaking\\\" time should be monitored and kept to a minimum. Refer to the Levelogger Series User Guide for further general maintenance recommendations.\"<!-- [et_pb_line_break_holder] -->    }<!-- [et_pb_line_break_holder] -->  }]<!-- [et_pb_line_break_holder] -->}<!-- [et_pb_line_break_holder] --><\/script>[\/et_pb_code][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner _builder_version=\u00bb4.27.2&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_column_inner saved_specialty_column_type=\u00bb3_4&#8243; _builder_version=\u00bb4.27.2&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][dsm_menu title=\u00bbProductos relacionados\u00bb menu_id=\u00bb37&#8243; submenu_collapse=\u00bbon\u00bb menu_link_text_color=\u00bb#000000&#8243; active_link_color=\u00bb#000000&#8243; menu_link_text_active_color=\u00bb#000000&#8243; menu_link_text_visited_color=\u00bb#000000&#8243; list_style_type=\u00bbnone\u00bb disabled_on=\u00bboff|off|on\u00bb admin_label=\u00bb403 Related Products Mobile\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb header_font=\u00bb|600|||||||\u00bb header_text_align=\u00bbleft\u00bb header_text_color=\u00bb#000000&#8243; header_font_size=\u00bb20px\u00bb menu_font_size=\u00bb16px\u00bb sub_menu_text_color=\u00bb#727272&#8243; background_color=\u00bb#fcfcfc\u00bb custom_padding=\u00bb10px|10px|10px|10px|false|false\u00bb sticky_limit_bottom=\u00bbbody\u00bb sticky_position_tablet=\u00bbnone\u00bb sticky_position_phone=\u00bbnone\u00bb sticky_position_last_edited=\u00bbon|tablet\u00bb border_width_all=\u00bb1px\u00bb border_color_all=\u00bb#e0e0e0&#8243; locked=\u00bboff\u00bb global_colors_info=\u00bb{}\u00bb active_link_color__hover_enabled=\u00bbon|hover\u00bb active_link_color__hover=\u00bb#d1d1d1&#8243;][\/dsm_menu][\/et_pb_column_inner][\/et_pb_row_inner][\/et_pb_column][\/et_pb_section][et_pb_section fb_built=\u00bb1&#8243; admin_label=\u00bbAdobe Analytics Code\u00bb _builder_version=\u00bb4.27.0&#8243; _module_preset=\u00bbdefault\u00bb custom_padding=\u00bb||4px|||\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_row _builder_version=\u00bb4.27.2&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_column type=\u00bb4_4&#8243; _builder_version=\u00bb4.27.0&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_code admin_label=\u00bbC\u00f3digo AA para esta p\u00e1gina\u00bb _builder_version=\u00bb4.27.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb]<!-- SiteCatalyst code version: H.21. Copyright 1996-2010 Adobe, Inc. All Rights Reserved More info available at http:\/\/www.omniture.com --><!-- [et_pb_line_break_holder] --><script language=\"JavaScript\" type=\"text\/javascript\" src=\"\/\/www.solinst.com\/s_code.js\"><\/script><!-- [et_pb_line_break_holder] --><script language=\"JavaScript\" type=\"text\/javascript\"><!--<!-- [et_pb_line_break_holder] -->s.pageName=\"3001 faq\"<!-- [et_pb_line_break_holder] -->s.server=\"\"<!-- [et_pb_line_break_holder] -->s.channel=\"products\"<!-- [et_pb_line_break_holder] -->s.pageType=\"\"<!-- [et_pb_line_break_holder] -->s.prop1=\"dataloggers and telemetry\"<!-- [et_pb_line_break_holder] -->s.prop2=\"3001 levelogger\"<!-- [et_pb_line_break_holder] -->s.prop3=\"3001 faq\"<!-- [et_pb_line_break_holder] -->s.prop4=\"\"<!-- [et_pb_line_break_holder] -->s.prop5=\"\"<!-- [et_pb_line_break_holder] -->s.prop6=\"\"<!-- [et_pb_line_break_holder] -->s.prop7=\"\"<!-- [et_pb_line_break_holder] -->s.prop8=\"\"<!-- [et_pb_line_break_holder] -->s.prop9=\"\"<!-- [et_pb_line_break_holder] -->s.prop10=\"\"<!-- [et_pb_line_break_holder] -->s.prop11=\"\"<!-- [et_pb_line_break_holder] -->s.prop12=\"\"<!-- [et_pb_line_break_holder] -->s.prop13=\"\"<!-- [et_pb_line_break_holder] -->s.prop14=\"\"<!-- [et_pb_line_break_holder] -->s.prop15=\"\"<!-- [et_pb_line_break_holder] -->s.prop16=\"\"<!-- [et_pb_line_break_holder] -->s.prop17=\"\"<!-- [et_pb_line_break_holder] -->s.prop18=\"\"<!-- [et_pb_line_break_holder] -->s.prop19=\"\"<!-- [et_pb_line_break_holder] -->s.prop20=\"\"<!-- [et_pb_line_break_holder] -->s.prop21=\"\"<!-- [et_pb_line_break_holder] -->s.prop22=\"\"<!-- [et_pb_line_break_holder] -->s.prop23=\"\"<!-- [et_pb_line_break_holder] -->s.prop24=\"\"<!-- [et_pb_line_break_holder] -->s.prop25=\"\"<!-- [et_pb_line_break_holder] -->s.prop26=\"\"<!-- [et_pb_line_break_holder] -->s.prop27=\"\"<!-- [et_pb_line_break_holder] -->s.prop28=\"\"<!-- [et_pb_line_break_holder] -->s.prop29=\"\"<!-- [et_pb_line_break_holder] -->s.prop30=\"\"<!-- [et_pb_line_break_holder] -->s.prop31=\"\"<!-- [et_pb_line_break_holder] -->s.prop32=\"\"<!-- [et_pb_line_break_holder] -->s.prop33=\"\"<!-- [et_pb_line_break_holder] -->s.hier1=\"solinst:products:dataloggers and telemetry:3001 levelogger:3001 faq\"<!-- [et_pb_line_break_holder] --><!-- [et_pb_line_break_holder] -->\/* Conversion Variables *\/<!-- [et_pb_line_break_holder] -->s.campaign=\"\"<!-- [et_pb_line_break_holder] -->s.events=\"\"<!-- [et_pb_line_break_holder] -->s.eVar1=\"\"<!-- [et_pb_line_break_holder] -->s.eVar2=\"\"<!-- [et_pb_line_break_holder] -->s.eVar3=\"\"<!-- [et_pb_line_break_holder] -->s.eVar4=\"\"<!-- [et_pb_line_break_holder] -->s.eVar5=\"\"<!-- [et_pb_line_break_holder] -->s.eVar6=\"\"<!-- [et_pb_line_break_holder] -->s.eVar7=\"\"<!-- [et_pb_line_break_holder] -->s.eVar8=\"\"<!-- [et_pb_line_break_holder] -->s.eVar9=\"\"<!-- [et_pb_line_break_holder] -->s.eVar10=\"\"<!-- [et_pb_line_break_holder] -->s.eVar11=\"\"<!-- [et_pb_line_break_holder] -->s.eVar12=\"\"<!-- [et_pb_line_break_holder] -->s.eVar13=\"\"<!-- [et_pb_line_break_holder] -->s.eVar14=\"\"<!-- [et_pb_line_break_holder] -->s.eVar15=\"\"<!-- [et_pb_line_break_holder] -->s.eVar16=\"\"<!-- [et_pb_line_break_holder] -->s.eVar17=\"\"<!-- [et_pb_line_break_holder] -->s.state=\"\"<!-- [et_pb_line_break_holder] -->s.zip=\"\"<!-- [et_pb_line_break_holder] -->\/************* DO NOT ALTER ANYTHING BELOW THIS LINE ! **************\/<!-- [et_pb_line_break_holder] -->var s_code=s.t();if(s_code)document.write(s_code)\/\/--><\/script><!-- [et_pb_line_break_holder] --><script language=\"JavaScript\" type=\"text\/javascript\"><!--<!-- [et_pb_line_break_holder] -->if(navigator.appVersion.indexOf('MSIE')>=0)document.write(unescape('%3C')+'!-'+'-')<!-- [et_pb_line_break_holder] -->\/\/--><\/script><!-- [et_pb_line_break_holder] --><noscript><!-- [et_pb_line_break_holder] -->  <a href=\"https:\/\/www.omniture.com\" title=\"Anal\u00edtica web\"><!-- [et_pb_line_break_holder] -->    <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/solinst.d2.sc.omtrdc.net\/b\/ss\/solinst-prod\/1\/H.21--NS\/0\" height=\"1\" width=\"1\" border=\"0\" alt=\"\"><!-- [et_pb_line_break_holder] -->  <\/a><!-- [et_pb_line_break_holder] --><\/noscript><!-- [et_pb_line_break_holder] --><!--\/DO NOT REMOVE\/--><!-- [et_pb_line_break_holder] --><!-- End SiteCatalyst code version: H.21. -->[\/et_pb_code][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p><div class=\"et_pb_module dsm_breadcrumbs dsm_breadcrumbs_0\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module_inner\">\n\t\t\t\t\t<nav class=\"dsm_breadcrumbs_wrap\">\n\t\t\t\t<ul class=\"dsm_breadcrumbs\" itemscope itemtype=\"https:\/\/schema.org\/BreadcrumbList\">\t\t\t<li class=\"dsm_breadcrumbs_item dsm_home_item dsm_home_item_custom\" itemprop=\"itemListElement\" itemscope\n\t\t\titemtype=\"https:\/\/schema.org\/ListItem\">\n\t\t\t\t<a href=\"https:\/\/www.solinst.com\/es\/\" itemprop=\"item\" target=\"\">\n\t\t\t\t\t<span class='dsm_home_text_wrapper'>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"et-pb-icon dsm_home_icon\">\ue009<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"dsm_home_text\" itemprop=\"name\">\n\t\t\t\t\t\t\t\tHome\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t<\/a>\n\t\t\t\t<meta itemprop=\"position\" content=\"1\" \/>\n\t\t\t<\/li>\n\n\t\t<li class=\"dsm_breadcrumbs_separator\"> <span class=\"et-pb-icon dsm_separator_icon\">5<\/span><\/li><\/ul>\n\t\t\t<\/nav>\n\t\t\t\t<\/div>\n\t\t\t<\/div> &nbsp; Control discreto de la profundidad de las aguas subterr\u00e1neas Reducir costes y tiempo de campo &nbsp; &nbsp; &nbsp;<div class=\"et_pb_module dsm_icon_list dsm_icon_list_0\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module_inner\">\n\t\t\t\t\t<ul class=\"dsm_icon_list_items dsm_icon_list_ltr_direction dsm_icon_list_layout_vertical\"><li class=\"dsm_icon_list_child dsm_icon_list_child_0\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<a href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/levelogger-faq\/3001-faq.pdf\" target=\"_blank\"><span class=\"dsm_icon_list_wrapper\"><span class=\"dsm_icon_list_icon\">\uf1c1<\/span><\/span><span class=\"dsm_icon_list_text\">3001 Levelogger 5 FAQ PDF<\/span><\/a>\n\t\t\t<\/li><\/ul>\n\t\t\t\t<\/div>\n\t\t\t<\/div>Preguntas generales frecuentes sobre Levelogger<div class=\"et_pb_module dsm_faq dsm_faq_0\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module_inner\">\n\t\t\t\t\t<div class=\"dsm-faq-container dsm-front\" data-accordion=\"on\" data-open_first_item=\"off\">\n\t\t\t\t\n\t\t\t <\/div>\n\t\t\t \n\t\t\t\n\t\t\t\t<\/div>\n\t\t\t<\/div><div class=\"dsm_faq_child_0 dsm-faq-item-wrapper\">\n\t\t\t\t<div class=\"dsm-title-wrapper\">\n\t\t\t\t <div class=\"dsm-title-inner-wrapper\">\n\t\t\t\t   <div class=\"dsm_open_icon\"><span>K<\/span><\/div>\n\t\t\t\t   <div class=\"dsm_close_icon\"><span>L<\/span><\/div>\n\t\t\t\t   \n\t\t\t\t   \n\t\t\t\t   <h3 class=\"dsm-faq-title\">\u00bfCu\u00e1l es la diferencia entre un Levelogger y un Barologger?<\/h3>\n\t\t\t\t <\/div> \n\t\t\t\t <div class=\"dsm-faq-item-inner-wrapper\">\n\t\t\t\t   \n\t\t\t\t   \n\t\t\t\t   \n\t\t\t\t   \n\t\t\t\t <\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"dsm-faq-content\"> Los Leveloggers registran los cambios en la presi\u00f3n absoluta (presi\u00f3n de la columna de agua + presi\u00f3n barom\u00e9trica) con el tiempo. El Barologger funciona y se comunica de forma similar al Levelogger, pero se utiliza por encima del nivel del agua para registrar la presi\u00f3n barom\u00e9trica ambiente con el fin de corregir barom\u00e9tricamente los datos registrados por los Leveloggers. Normalmente, un Barologger puede cubrir un radio de 30 km (20 millas) y\/o cada 300 m (1000 pies) de cambio de elevaci\u00f3n. V\u00e9ase el bolet\u00edn t\u00e9cnico: Compensaci\u00f3n barom\u00e9trica e importancia de los datos barom\u00e9tricos <\/div>\n\t\t\t <\/div>\n\t\t\t<div class=\"dsm_faq_child_1 dsm-faq-item-wrapper\">\n\t\t\t\t<div class=\"dsm-title-wrapper\">\n\t\t\t\t <div class=\"dsm-title-inner-wrapper\">\n\t\t\t\t   <div class=\"dsm_open_icon\"><span>K<\/span><\/div>\n\t\t\t\t   <div class=\"dsm_close_icon\"><span>L<\/span><\/div>\n\t\t\t\t   \n\t\t\t\t   \n\t\t\t\t   <h3 class=\"dsm-faq-title\">\u00bb\u00bfCu\u00e1l<\/h3>\n\t\t\t\t <\/div> \n\t\t\t\t <div class=\"dsm-faq-item-inner-wrapper\">\n\t\t\t\t   \n\t\t\t\t   \n\t\t\t\t   \n\t\t\t\t   \n\t\t\t\t <\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"dsm-faq-content\">\u00bb<\/div>\n\t\t\t <\/div>\n\t\t\t<\/p>\n","protected":false},"author":1,"featured_media":189867,"parent":63103,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"folder":[381],"class_list":["post-154681","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v27.2) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Levelogger FAQ Preguntas m\u00e1s frecuentes<\/title>\n<meta name=\"description\" content=\"Obtenga respuestas r\u00e1pidas a sus preguntas t\u00e9cnicas sobre el registrador de nivel Solinst. Encuentre consejos para la resoluci\u00f3n de problemas, gu\u00edas de configuraci\u00f3n detalladas, requisitos de calibraci\u00f3n y ayuda para la descarga de datos.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Levelogger FAQ Preguntas m\u00e1s frecuentes\" \/>\n<meta property=\"og:description\" content=\"Obtenga respuestas r\u00e1pidas a sus preguntas t\u00e9cnicas sobre el registrador de nivel Solinst. Encuentre consejos para la resoluci\u00f3n de problemas, gu\u00edas de configuraci\u00f3n detalladas, requisitos de calibraci\u00f3n y ayuda para la descarga de datos.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/\" \/>\n<meta property=\"og:site_name\" content=\"Solinst Groundwater and Surface Water Monitoring Instrumentation, Water Level Meters, Interface Meters, Dataloggers\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-20T21:26:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solinst.com\/wp-content\/uploads\/2026\/02\/featureimage-3001-faqs.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"47 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/\",\"url\":\"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/\",\"name\":\"Levelogger FAQ Preguntas m\u00e1s frecuentes\",\"isPartOf\":{\"@id\":\"https:\/\/www.solinst.com\/es\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.solinst.com\/wp-content\/uploads\/2026\/02\/featureimage-3001-faqs.jpg\",\"datePublished\":\"2026-01-09T20:51:33+00:00\",\"dateModified\":\"2026-03-20T21:26:34+00:00\",\"description\":\"Obtenga respuestas r\u00e1pidas a sus preguntas t\u00e9cnicas sobre el registrador de nivel Solinst. Encuentre consejos para la resoluci\u00f3n de problemas, gu\u00edas de configuraci\u00f3n detalladas, requisitos de calibraci\u00f3n y ayuda para la descarga de datos.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/#primaryimage\",\"url\":\"https:\/\/www.solinst.com\/wp-content\/uploads\/2026\/02\/featureimage-3001-faqs.jpg\",\"contentUrl\":\"https:\/\/www.solinst.com\/wp-content\/uploads\/2026\/02\/featureimage-3001-faqs.jpg\",\"width\":1200,\"height\":675},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.solinst.com\/es\/inicio\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Productos\",\"item\":\"https:\/\/www.solinst.com\/es\/productos\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Registradores de datos y sistemas de telemetr\u00eda\",\"item\":\"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"3001 Nivelador\",\"item\":\"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"Levelogger FAQ Preguntas m\u00e1s frecuentes\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.solinst.com\/es\/#website\",\"url\":\"https:\/\/www.solinst.com\/es\/\",\"name\":\"Solinst Groundwater and Surface Water Monitoring Instrumentation, Water Level Meters, Interface Meters, Dataloggers\",\"description\":\"High quality groundwater monitoring instruments and surface water monitoring instruments including water level meters, interface meters, groundwater samplers, dataloggers and more!\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.solinst.com\/es\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Levelogger FAQ Preguntas m\u00e1s frecuentes","description":"Obtenga respuestas r\u00e1pidas a sus preguntas t\u00e9cnicas sobre el registrador de nivel Solinst. Encuentre consejos para la resoluci\u00f3n de problemas, gu\u00edas de configuraci\u00f3n detalladas, requisitos de calibraci\u00f3n y ayuda para la descarga de datos.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/","og_locale":"es_ES","og_type":"article","og_title":"Levelogger FAQ Preguntas m\u00e1s frecuentes","og_description":"Obtenga respuestas r\u00e1pidas a sus preguntas t\u00e9cnicas sobre el registrador de nivel Solinst. Encuentre consejos para la resoluci\u00f3n de problemas, gu\u00edas de configuraci\u00f3n detalladas, requisitos de calibraci\u00f3n y ayuda para la descarga de datos.","og_url":"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/","og_site_name":"Solinst Groundwater and Surface Water Monitoring Instrumentation, Water Level Meters, Interface Meters, Dataloggers","article_modified_time":"2026-03-20T21:26:34+00:00","og_image":[{"width":1200,"height":675,"url":"https:\/\/www.solinst.com\/wp-content\/uploads\/2026\/02\/featureimage-3001-faqs.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Tiempo de lectura":"47 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/","url":"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/","name":"Levelogger FAQ Preguntas m\u00e1s frecuentes","isPartOf":{"@id":"https:\/\/www.solinst.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/#primaryimage"},"image":{"@id":"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solinst.com\/wp-content\/uploads\/2026\/02\/featureimage-3001-faqs.jpg","datePublished":"2026-01-09T20:51:33+00:00","dateModified":"2026-03-20T21:26:34+00:00","description":"Obtenga respuestas r\u00e1pidas a sus preguntas t\u00e9cnicas sobre el registrador de nivel Solinst. Encuentre consejos para la resoluci\u00f3n de problemas, gu\u00edas de configuraci\u00f3n detalladas, requisitos de calibraci\u00f3n y ayuda para la descarga de datos.","breadcrumb":{"@id":"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/#primaryimage","url":"https:\/\/www.solinst.com\/wp-content\/uploads\/2026\/02\/featureimage-3001-faqs.jpg","contentUrl":"https:\/\/www.solinst.com\/wp-content\/uploads\/2026\/02\/featureimage-3001-faqs.jpg","width":1200,"height":675},{"@type":"BreadcrumbList","@id":"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/levelogger-faq-preguntas-mas-frecuentes\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.solinst.com\/es\/inicio\/"},{"@type":"ListItem","position":2,"name":"Productos","item":"https:\/\/www.solinst.com\/es\/productos\/"},{"@type":"ListItem","position":3,"name":"Registradores de datos y sistemas de telemetr\u00eda","item":"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/"},{"@type":"ListItem","position":4,"name":"3001 Nivelador","item":"https:\/\/www.solinst.com\/es\/productos\/registradores-de-datos-y-sistemas-de-telemetria\/3001-nivelador\/"},{"@type":"ListItem","position":5,"name":"Levelogger FAQ Preguntas m\u00e1s frecuentes"}]},{"@type":"WebSite","@id":"https:\/\/www.solinst.com\/es\/#website","url":"https:\/\/www.solinst.com\/es\/","name":"Solinst Groundwater and Surface Water Monitoring Instrumentation, Water Level Meters, Interface Meters, Dataloggers","description":"High quality groundwater monitoring instruments and surface water monitoring instruments including water level meters, interface meters, groundwater samplers, dataloggers and more!","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solinst.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"}]}},"_links":{"self":[{"href":"https:\/\/www.solinst.com\/es\/wp-json\/wp\/v2\/pages\/154681","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solinst.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.solinst.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/es\/wp-json\/wp\/v2\/comments?post=154681"}],"version-history":[{"count":58,"href":"https:\/\/www.solinst.com\/es\/wp-json\/wp\/v2\/pages\/154681\/revisions"}],"predecessor-version":[{"id":205574,"href":"https:\/\/www.solinst.com\/es\/wp-json\/wp\/v2\/pages\/154681\/revisions\/205574"}],"up":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/es\/wp-json\/wp\/v2\/pages\/63103"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/es\/wp-json\/wp\/v2\/media\/189867"}],"wp:attachment":[{"href":"https:\/\/www.solinst.com\/es\/wp-json\/wp\/v2\/media?parent=154681"}],"wp:term":[{"taxonomy":"folder","embeddable":true,"href":"https:\/\/www.solinst.com\/es\/wp-json\/wp\/v2\/folder?post=154681"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}