<style type="text/css">a[data-mtli~="mtli_filesize35806kB"]:after {content:" (358.06 kB)"}</style>{"id":1602,"date":"2019-06-03T09:00:19","date_gmt":"2019-06-03T13:00:19","guid":{"rendered":"http:\/\/www.solinst.com\/onthelevel-news\/?p=1602"},"modified":"2022-03-23T16:44:01","modified_gmt":"2022-03-23T20:44:01","slug":"understanding-pressure-sensor-accuracy-precision-resolution-drift","status":"publish","type":"post","link":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/","title":{"rendered":"Understanding Pressure Sensor Accuracy, Precision, Resolution &#038; Drift"},"content":{"rendered":"\n<div id=\"solid-grey-box\" class=\"floatRight\"><a href=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/technical-bulletins\/understanding-pressure-sensor-drift.pdf\" class=\"mtli_attachment mtli_pdf\" data-mtli=\"mtli_filesize35806kB\" target=\"_blank\" rel=\"noopener noreferrer\">Download Technical Bulletin<\/a><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Accuracy, Precision &amp; Resolution<\/h2>\n\n\n\n<p>Accuracy, resolution, and precision are often interchanged when discussing the specifications of a pressure sensor. Here, we will differentiate between the three in relation to <a title=\"Solinst Levelogger 5 Water Level Dataloggers\" href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/levelogger\/\" target=\"_blank\" rel=\"noopener noreferrer\">Solinst Levelogger<\/a>, <a title=\"Solinst LevelVent Vented Water Level Dataloggers\" href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3250-levelvent\/levelvent.php\" target=\"_blank\" rel=\"noopener noreferrer\">LevelVent<\/a>, and <a title=\"Solinst AquaVent Vented Water Level Dataloggers\" href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3500-aquavent\/aquavent.php\" target=\"_blank\" rel=\"noopener noreferrer\">AquaVent<\/a> datalogger pressure sensors.<span class=\"Apple-converted-space\">&nbsp;<\/span><\/p>\n\n\n\n<div class=\"wp-block-image wp-image-3244 size-large\"><figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"476\" src=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2019\/06\/L5-LV5-AV5-1024x476.jpg\" alt=\"solinst absolute and vented water level dataloggers\" class=\"wp-image-3244\" srcset=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2019\/06\/L5-LV5-AV5-1024x476.jpg 1024w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2019\/06\/L5-LV5-AV5-300x140.jpg 300w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2019\/06\/L5-LV5-AV5-768x357.jpg 768w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2019\/06\/L5-LV5-AV5-624x290.jpg 624w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2019\/06\/L5-LV5-AV5.jpg 1103w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption>Solinst Levelogger, LevelVent and AquaVent Water Level Dataloggers<\/figcaption><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Pressure Sensor Accuracy<\/h3>\n\n\n\n<p>Accuracy is how closely the measured value reported by the pressure sensor comes to the actual pressure. It is stated as the difference between the two values, expressed as a percent of the sensor\u2019s full scale (FS).<span class=\"Apple-converted-space\">&nbsp;<\/span><\/p>\n\n\n\n<p>For example, if the Levelogger 5 M100 with a full scale of 100 m reports a pressure of 88.0500 m, and the actual pressure is 88.0000 m, then the difference is 0.0500 m (5 cm); divide 0.0500 m by 100 m and express as a percentage \u2013 accuracy (or error) is 0.05%.&nbsp;The Solinst Levelogger 5, LevelVent 5, and AquaVent 5 have an accuracy of \u00b10.05% FS.<span class=\"Apple-converted-space\">&nbsp;<\/span><\/p>\n\n\n\n<p>An accurate pressure sensor must also limit non-linearity and hysteresis.<span class=\"Apple-converted-space\">&nbsp; <\/span>Non-linearity is the deviation of the sensors output from a specified best fit straight line over the full scale. Hysteresis is the maximum difference in the value of the readings at a specific point, one reading is obtained while increasing the pressure and the other while decreasing from full scale.<span class=\"Apple-converted-space\">&nbsp;<\/span><\/p>\n\n\n\n<div class=\"wp-block-image wp-image-2948 size-full\"><figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"612\" height=\"327\" src=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2012\/03\/Pressure-Sensor-Accuracy.jpg\" alt=\"example of non-linearity and hysteresis\" class=\"wp-image-2948\" srcset=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2012\/03\/Pressure-Sensor-Accuracy.jpg 612w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2012\/03\/Pressure-Sensor-Accuracy-300x160.jpg 300w\" sizes=\"auto, (max-width: 612px) 100vw, 612px\" \/><figcaption>Non-linearity and Hysteresis<\/figcaption><\/figure><\/div>\n\n\n\n<p>The Solinst datalogger calibration procedure ensures linearity and hysteresis specifications are met. During the calibration procedure, the datalogger is fully submerged in a highly accurate water bath. The bath is allowed to stabilize. The pressure is then calibrated to six separate pressure points covering the entire range of pressure to check for any non-linearity and hysteresis (the procedure is repeated at two more temperatures).<span class=\"Apple-converted-space\">&nbsp;<\/span><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pressure Sensor Precision<\/h3>\n\n\n\n<p>Precision is how close all the sensor readings are grouped to each other \u2013 a more precise sensor has a narrow distribution of readings at a given pressure. In other words, a precise pressure transducer produces consistently repeatable measurements.<span class=\"Apple-converted-space\">&nbsp;<\/span><\/p>\n\n\n\n<div class=\"wp-block-image wp-image-2949 size-full\"><figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"612\" height=\"342\" src=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2012\/03\/Pressure-Sensor-Accuracy-2.jpg\" alt=\"pressure sensor accuracy vs precision\" class=\"wp-image-2949\" srcset=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2012\/03\/Pressure-Sensor-Accuracy-2.jpg 612w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2012\/03\/Pressure-Sensor-Accuracy-2-300x168.jpg 300w\" sizes=\"auto, (max-width: 612px) 100vw, 612px\" \/><figcaption>Accuracy vs. Precision<\/figcaption><\/figure><\/div>\n\n\n\n<p>Solinst datalogger pressure sensors are precise with superior stability and low noise.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pressure Sensor Resolution<\/h3>\n\n\n\n<p>Resolution is the smallest degree of pressure change that can be detected and recorded by the pressure sensor. <span class=\"Apple-converted-space\">&nbsp;<\/span><\/p>\n\n\n\n<p>For example, the Levelogger 5 M100 has a resolution of 0.0006% FS. This means with a full scale of 100 m, the sensor will be able to detect a 0.0006 m (0.6 mm) change in pressure. Resolution usually varies over the range of the instruments, e.g. the Levelogger 5 M5 has a resolution of 0.001% FS<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pressure Sensor Drift<\/h2>\n\n\n\n<p>All pressure transducers \u2013 no matter what they are made of, how expensive they are, or how accurate \u2013 are susceptible to sensor drift over time. Pressure sensor drift is a gradual degradation of the sensor and other components that can make readings offset from the original calibrated state.<\/p>\n\n\n\n<div class=\"wp-block-image wp-image-2951 size-full\"><figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"612\" height=\"310\" src=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2012\/03\/Pressure-Sensor-Drift.jpg\" alt=\"example of pressure sensor drift from the calibrated zero point over time\" class=\"wp-image-2951\" srcset=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2012\/03\/Pressure-Sensor-Drift.jpg 612w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2012\/03\/Pressure-Sensor-Drift-300x152.jpg 300w\" sizes=\"auto, (max-width: 612px) 100vw, 612px\" \/><figcaption>Example of Pressure Sensor Drift from the Calibrated Zero Point Over Time<\/figcaption><\/figure><\/div>\n\n\n\n<p>Based on their intended application, sensors are engineered from various materials. When exposed to certain conditions, the sensors will respond differently depending on the physical properties of the materials chosen.<span class=\"Apple-converted-space\">&nbsp;<\/span><\/p>\n\n\n\n<p>Every sensor will undergo some expansion and contraction when subject to pressure and temperature cycles. Pressure change frequency and amplitude, temperature extremes, material responses and environmental changes are all factors contributing to drift. The magnitude a sensor will drift varies with actual usage and the conditions it is exposed to.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><b>Pressure Sensor Calibration<\/b><\/h3>\n\n\n\n<p>It is important to note that manufacturers test and calibrate their sensors in closed environments to achieve desired specifications and a zero point. Some manufacturers provide a value for the expected drift or long term stability, but these numbers are still based on use in very stable environments, making them somewhat irrelevant in normal use.<span class=\"Apple-converted-space\">&nbsp;<\/span><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Solinst Pressure Sensors<\/h3>\n\n\n\n<p>Solinst Leveloggers are water level dataloggers that use an absolute pressure sensor to detect the depth (or pressure) of water above the logger. For the Levelogger 5, Solinst chose to use a Hastelloy pressure sensor because of durability, long term stability, accuracy, and corrosion resistance. LevelVent 5 and AquaVent 5 water level dataloggers also use a Hastelloy pressure sensor, but it is vented to the atmosphere.<span class=\"Apple-converted-space\">&nbsp;<\/span><\/p>\n\n\n\n<p>Hastelloy pressure sensors are more tolerant when it comes to being over-pressurized. Other sensors, such as ceramic sensors, tend to be more brittle and can shatter when they experience over-pressurization, ice accumulation, or water hammer effects.<\/p>\n\n\n\n<div class=\"wp-block-media-text alignwide\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2022\/03\/30015prodtour-i-2x-768x1024.jpg\" alt=\"solinst levelogger 5 series of water level dataloggers\" class=\"wp-image-3868\" srcset=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2022\/03\/30015prodtour-i-2x-768x1024.jpg 768w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2022\/03\/30015prodtour-i-2x-225x300.jpg 225w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2022\/03\/30015prodtour-i-2x-624x832.jpg 624w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2022\/03\/30015prodtour-i-2x.jpg 900w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"has-text-color has-background has-normal-font-size has-luminous-vivid-orange-color has-very-light-gray-background-color\">The Model 3001 Levelogger 5 is an accurate water level and temperature datalogger that provides a compact method of recording uninterrupted, long-term data. The Levelogger 5 consists of an absolute pressure sensor, temperature thermistor, datalogger and 10-year lithium battery, in a stainless steel housing with a PFAS-free corrosion-resistant coating inside and out. A memory for 150,000 sets of readings allows higher-resolution data with more frequent readings. Accuracy is 0.05% FS.<br><a href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/get-quote.php\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\"Get a Quote!  (opens in a new tab)\">Get a Quote! <\/a><\/p>\n<\/div><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Correcting for Drift<\/h3>\n\n\n\n<p>Factory re-calibration can be attempted to correct for drift, but may not be required. Regular \u201cfield zero readings\u201d will serve to eliminate the effects of drift on pressure sensor readings.<span class=\"Apple-converted-space\">&nbsp;<\/span><\/p>\n\n\n\n<p>The best recommendation is to compare barometrically compensated Levelogger data (or raw LevelVent and AquaVent data) with a manually measured water level value (depth to water using a <a title=\"Solinst Model 101 Water Level Meter\" href=\"https:\/\/www.solinst.com\/products\/level-measurement-devices\/101-water-level-meter\/\" target=\"_blank\" rel=\"noopener noreferrer\">Model 101 Water Level Meter<\/a>, <a title=\"Solinst Model 101D Water Level DrawDown Meter\" href=\"https:\/\/www.solinst.com\/products\/level-measurement-devices\/101d-water-level-drawdown-meter\/101d.php\" target=\"_blank\" rel=\"noopener noreferrer\">101D Water Level DrawDown Meter<\/a>, or <a title=\"Solinst Model 102 Water Level Meter\" href=\"https:\/\/www.solinst.com\/products\/level-measurement-devices\/102-water-level-indicator\/\" target=\"_blank\" rel=\"noopener noreferrer\">102 Water Level Meter<\/a>, or a staff gauge depending on your application).<span class=\"Apple-converted-space\">&nbsp;<\/span><\/p>\n\n\n\n<p>By routinely taking manual water level measurements, and comparing these readings to those recorded by the datalogger at the same time, an offset value can be determined. This <a title=\"How to Set an Offset Value for Levelogger Water Level Dataloggers\" href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/user-guide\/5-levelogger-edge-series-setup\/5-1-1-1-level-channel.php\" target=\"_blank\" rel=\"noopener noreferrer\">offset value<\/a> can then be used to correct future datalogger readings.<\/p>\n\n\n\n<p>For example, If using a depth to water measurement for comparison, the deployment depth of the Levelogger, minus the manual depth to water measurement, should equal the compensated Levelogger reading. If not, the difference between the two readings is the offset value, or calculated sensor drift.<\/p>\n\n\n\n<div class=\"wp-block-image size-full wp-image-3382\"><figure class=\"alignright\"><img loading=\"lazy\" decoding=\"async\" width=\"891\" height=\"677\" src=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2019\/06\/Datalogger-Settings-Offset.jpg\" alt=\"levelogger 5 offset setting option\" class=\"wp-image-3382\" srcset=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2019\/06\/Datalogger-Settings-Offset.jpg 891w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2019\/06\/Datalogger-Settings-Offset-300x228.jpg 300w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2019\/06\/Datalogger-Settings-Offset-768x584.jpg 768w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2019\/06\/Datalogger-Settings-Offset-624x474.jpg 624w\" sizes=\"auto, (max-width: 891px) 100vw, 891px\" \/><figcaption>An Offset Value can be entered when programming a datalogger using Levelogger Software to account for pressure sensor drift.<\/figcaption><\/figure><\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Accuracy, resolution, and precision are often interchanged when discussing the specifications of a pressure sensor. Here, we will differentiate between the three in relation to Solinst Levelogger, LevelVent, and AquaVent datalogger pressure sensors.  <span class=\"continue-reading\"><a href=\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/\" style=\"color: #666;\">Continue Reading &raquo;<\/a><\/span><\/p>\n","protected":false},"author":2,"featured_media":2958,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[454],"tags":[88,101,371,456,487,527,543,544,545],"class_list":["post-1602","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-water-level-datalogging","tag-levelogger-data","tag-levelogger-software","tag-pressure-sensor-drift","tag-3001-levelogger","tag-3500-aquavent","tag-3250-levelvent","tag-pressure-sensor-accuracy","tag-pressure-sensor-precision","tag-pressure-sensor-resolution"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Understanding Pressure Sensor Accuracy, Precision, Resolution &amp; Drift<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Understanding Pressure Sensor Accuracy, Precision, Resolution &amp; Drift\" \/>\n<meta property=\"og:description\" content=\"Accuracy, resolution, and precision are often interchanged when discussing the specifications of a pressure sensor. Here, we will differentiate between the three in relation to Solinst Levelogger, LevelVent, and AquaVent datalogger pressure sensors. Continue Reading &raquo;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/\" \/>\n<meta property=\"og:site_name\" content=\"On The Level Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/solinstcanada\/\" \/>\n<meta property=\"article:published_time\" content=\"2019-06-03T13:00:19+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-03-23T20:44:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2012\/03\/Pressure-Sensor-Accuracy-thumb-e1576250157792.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"150\" \/>\n\t<meta property=\"og:image:height\" content=\"150\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Tricia Lane\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2020\/04\/Levelogger-Offset-Setting.png\" \/>\n<meta name=\"twitter:creator\" content=\"@solinstcanada\" \/>\n<meta name=\"twitter:site\" content=\"@solinstcanada\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tricia Lane\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/understanding-pressure-sensor-accuracy-precision-resolution-drift\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/understanding-pressure-sensor-accuracy-precision-resolution-drift\\\/\"},\"author\":{\"name\":\"Tricia Lane\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/#\\\/schema\\\/person\\\/23ea69464d8e973f9c3ef8091ea2a94d\"},\"headline\":\"Understanding Pressure Sensor Accuracy, Precision, Resolution &#038; Drift\",\"datePublished\":\"2019-06-03T13:00:19+00:00\",\"dateModified\":\"2022-03-23T20:44:01+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/understanding-pressure-sensor-accuracy-precision-resolution-drift\\\/\"},\"wordCount\":973,\"image\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/understanding-pressure-sensor-accuracy-precision-resolution-drift\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/wp-content\\\/uploads\\\/2012\\\/03\\\/Pressure-Sensor-Accuracy-thumb-e1576250157792.jpg\",\"keywords\":[\"levelogger data\",\"levelogger software\",\"pressure sensor drift\",\"3001 levelogger\",\"3500 aquavent\",\"3250 levelvent\",\"pressure sensor accuracy\",\"pressure sensor precision\",\"pressure sensor resolution\"],\"articleSection\":[\"Water Level Datalogging\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/understanding-pressure-sensor-accuracy-precision-resolution-drift\\\/\",\"url\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/understanding-pressure-sensor-accuracy-precision-resolution-drift\\\/\",\"name\":\"Understanding Pressure Sensor Accuracy, Precision, Resolution & Drift\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/understanding-pressure-sensor-accuracy-precision-resolution-drift\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/understanding-pressure-sensor-accuracy-precision-resolution-drift\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/wp-content\\\/uploads\\\/2012\\\/03\\\/Pressure-Sensor-Accuracy-thumb-e1576250157792.jpg\",\"datePublished\":\"2019-06-03T13:00:19+00:00\",\"dateModified\":\"2022-03-23T20:44:01+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/#\\\/schema\\\/person\\\/23ea69464d8e973f9c3ef8091ea2a94d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/understanding-pressure-sensor-accuracy-precision-resolution-drift\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/understanding-pressure-sensor-accuracy-precision-resolution-drift\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/understanding-pressure-sensor-accuracy-precision-resolution-drift\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/wp-content\\\/uploads\\\/2012\\\/03\\\/Pressure-Sensor-Accuracy-thumb-e1576250157792.jpg\",\"contentUrl\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/wp-content\\\/uploads\\\/2012\\\/03\\\/Pressure-Sensor-Accuracy-thumb-e1576250157792.jpg\",\"width\":150,\"height\":150,\"caption\":\"pressure sensor non-linearity and hysteresis\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/understanding-pressure-sensor-accuracy-precision-resolution-drift\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Understanding Pressure Sensor Accuracy, Precision, Resolution &#038; Drift\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/#website\",\"url\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/\",\"name\":\"On The Level Blog\",\"description\":\"Water Monitoring News and Updates\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/#\\\/schema\\\/person\\\/23ea69464d8e973f9c3ef8091ea2a94d\",\"name\":\"Tricia Lane\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g\",\"caption\":\"Tricia Lane\"},\"url\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/author\\\/tricia-lane\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Understanding Pressure Sensor Accuracy, Precision, Resolution & Drift","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/","og_locale":"en_US","og_type":"article","og_title":"Understanding Pressure Sensor Accuracy, Precision, Resolution & Drift","og_description":"Accuracy, resolution, and precision are often interchanged when discussing the specifications of a pressure sensor. Here, we will differentiate between the three in relation to Solinst Levelogger, LevelVent, and AquaVent datalogger pressure sensors. Continue Reading &raquo;","og_url":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/","og_site_name":"On The Level Blog","article_publisher":"https:\/\/www.facebook.com\/solinstcanada\/","article_published_time":"2019-06-03T13:00:19+00:00","article_modified_time":"2022-03-23T20:44:01+00:00","og_image":[{"width":150,"height":150,"url":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2012\/03\/Pressure-Sensor-Accuracy-thumb-e1576250157792.jpg","type":"image\/jpeg"}],"author":"Tricia Lane","twitter_card":"summary_large_image","twitter_image":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2020\/04\/Levelogger-Offset-Setting.png","twitter_creator":"@solinstcanada","twitter_site":"@solinstcanada","twitter_misc":{"Written by":"Tricia Lane","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/#article","isPartOf":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/"},"author":{"name":"Tricia Lane","@id":"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/23ea69464d8e973f9c3ef8091ea2a94d"},"headline":"Understanding Pressure Sensor Accuracy, Precision, Resolution &#038; Drift","datePublished":"2019-06-03T13:00:19+00:00","dateModified":"2022-03-23T20:44:01+00:00","mainEntityOfPage":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/"},"wordCount":973,"image":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2012\/03\/Pressure-Sensor-Accuracy-thumb-e1576250157792.jpg","keywords":["levelogger data","levelogger software","pressure sensor drift","3001 levelogger","3500 aquavent","3250 levelvent","pressure sensor accuracy","pressure sensor precision","pressure sensor resolution"],"articleSection":["Water Level Datalogging"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/","url":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/","name":"Understanding Pressure Sensor Accuracy, Precision, Resolution & Drift","isPartOf":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/#primaryimage"},"image":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2012\/03\/Pressure-Sensor-Accuracy-thumb-e1576250157792.jpg","datePublished":"2019-06-03T13:00:19+00:00","dateModified":"2022-03-23T20:44:01+00:00","author":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/23ea69464d8e973f9c3ef8091ea2a94d"},"breadcrumb":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/#primaryimage","url":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2012\/03\/Pressure-Sensor-Accuracy-thumb-e1576250157792.jpg","contentUrl":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2012\/03\/Pressure-Sensor-Accuracy-thumb-e1576250157792.jpg","width":150,"height":150,"caption":"pressure sensor non-linearity and hysteresis"},{"@type":"BreadcrumbList","@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/understanding-pressure-sensor-accuracy-precision-resolution-drift\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.solinst.com\/onthelevel-news\/"},{"@type":"ListItem","position":2,"name":"Understanding Pressure Sensor Accuracy, Precision, Resolution &#038; Drift"}]},{"@type":"WebSite","@id":"https:\/\/www.solinst.com\/onthelevel-news\/#website","url":"https:\/\/www.solinst.com\/onthelevel-news\/","name":"On The Level Blog","description":"Water Monitoring News and Updates","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solinst.com\/onthelevel-news\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/23ea69464d8e973f9c3ef8091ea2a94d","name":"Tricia Lane","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g","caption":"Tricia Lane"},"url":"https:\/\/www.solinst.com\/onthelevel-news\/author\/tricia-lane\/"}]}},"jetpack_featured_media_url":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2012\/03\/Pressure-Sensor-Accuracy-thumb-e1576250157792.jpg","_links":{"self":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts\/1602","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/comments?post=1602"}],"version-history":[{"count":20,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts\/1602\/revisions"}],"predecessor-version":[{"id":3893,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts\/1602\/revisions\/3893"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/media\/2958"}],"wp:attachment":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/media?parent=1602"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/categories?post=1602"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/tags?post=1602"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}