<style type="text/css">a[data-mtli~="mtli_filesize21665kB"]:after {content:" (216.65 kB)"}</style>{"id":1651,"date":"2020-01-13T13:51:00","date_gmt":"2020-01-13T18:51:00","guid":{"rendered":"http:\/\/www.solinst.com\/onthelevel-news\/?p=1651"},"modified":"2024-07-17T12:00:57","modified_gmt":"2024-07-17T16:00:57","slug":"getting-the-best-quality-samples-from-your-double-valve-pump","status":"publish","type":"post","link":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/","title":{"rendered":"Getting The Best Quality Samples From Your Double Valve Pump"},"content":{"rendered":"<h2 class=\"subhead\">Solinst\u00a0Double Valve Pumps<\/h2>\n<div id=\"solid-grey-box\" class=\"floatRight\"><a href=\"\/products\/groundwater-samplers\/408-double-valve-pumps\/technical-bulletins\/getting-best-quality-samples-double-valve-pump.pdf\" class=\"mtli_attachment mtli_pdf\" data-mtli=\"mtli_filesize21665kB\" target=\"_blank\" rel=\"noopener noreferrer\">Download Technical Bulletin<\/a><\/div>\n<p><a href=\"http:\/\/www.solinst.com\/products\/groundwater-samplers\/408-double-valve-pumps\/\" target=\"_blank\" rel=\"noopener noreferrer\">Double Valve Pumps<\/a> can provide high quality, representative groundwater samples. However, to get the best quality samples from your pump, it is critical to understand how the Double Valve Pump works and how to operate it properly.<\/p>\n<div id=\"attachment_3164\" style=\"width: 1210px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3164\" class=\"wp-image-3164 size-full\" title=\"Solinst Double Valve Pumps For Groundwater Sampling\" src=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2020\/01\/408-Set-with-Barbs.jpg\" alt=\"solinst double valve pumps for groundwater sampling\" width=\"1200\" height=\"400\" srcset=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2020\/01\/408-Set-with-Barbs.jpg 1200w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2020\/01\/408-Set-with-Barbs-300x100.jpg 300w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2020\/01\/408-Set-with-Barbs-1024x341.jpg 1024w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2020\/01\/408-Set-with-Barbs-768x256.jpg 768w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2020\/01\/408-Set-with-Barbs-624x208.jpg 624w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><p id=\"caption-attachment-3164\" class=\"wp-caption-text\">Solinst 1.66&#8243; and 5\/8&#8243; Stainless Steel Double Valve Pumps<\/p><\/div>\n<h2 class=\"subhead\">Double Valve Pump Operating Principles<\/h2>\n<p>When a Double Valve Pump is submerged, hydrostatic pressure forces water through the filter intake in the base of the pump, filling the pump body and both the drive and sample lines to static level.<\/p>\n<p>Pressure is applied to the drive line using a compressed air source and a pump control unit. During the drive period on the control unit, the pressure pushes down on the water column in the drive line, which forces the water in the pump up the sample line. A check valve at the bottom of the pump closes to prevent water from exiting the pump during the drive period.<\/p>\n<p>After the drive period, the pump control unit switches to vent, and pressure is released. New formation water flows into the pump and drive line, while a check valve at the top of the pump closes to prevent water from draining back down the sample line.<\/p>\n<p>After venting, pressure is re-applied, again forcing water from the pump and raising the water in the sample line closer to the surface. Repeating the drive and vent cycle will eventually cause the water in the sample line to discharge at surface in a gentle pulsating flow.<\/p>\n<p>See the\u00a0<a title=\"Solinst Double Valve Pump Operating Principles\" href=\"http:\/\/www.solinst.com\/products\/groundwater-samplers\/408-double-valve-pumps\/operating-instructions\/double-valve-pump-operating-principles.php\"><strong>Double Valve Pump Operating Principles<\/strong><\/a>\u00a0document for a detailed illustration of the Double Valve Pump operation, or check out the video below.<\/p>\n<p><iframe loading=\"lazy\" title=\"How Double Valve Pumps Provide Quality Groundwater Samples\" width=\"625\" height=\"352\" src=\"https:\/\/www.youtube.com\/embed\/9kw3jbS_vHA?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>\n<h2 class=\"subhead\">Optimizing Pressure<\/h2>\n<p>The key to a representative sample, especially when monitoring for volatiles, is to not allow drive gas to enter the pump and aerate the sample water during a drive period. This means you need to carefully calculate the appropriate amount of pressure to be applied. Always calculate pressure based on depth to static water level (plus 10 psi for line loss), increasing only incrementally to improve performance.<\/p>\n<p>The pressure needed is calculated based on the fact that it takes about 1 psi of pressure to raise 2.3 ft. of water. To calculate pressure needed in psi, take depth to static level in feet, and multiply by 0.43 psi\/ft. (1 psi \/ 2.3 feet = 0.43 psi\/ft.). E.g., if depth to static water level is 50 ft., the pressure needed is calculated by the following:<br \/>50 ft. to static level x 0.43 psi\/ft. + 10 psi = 32 psi needed.<\/p>\n<h2 class=\"subhead\">Helpful Hints<\/h2>\n<h4><strong>Drive Gas Recommendations<\/strong><\/h4>\n<p>For applications to depths of 100 ft (30 m) or less, a <a href=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/407-bladder-pumps\/operating-instructions\/12-volt-compressor.php\" target=\"_blank\" rel=\"noopener noreferrer\">Solinst 12 Volt Compressor<\/a> is an excellent option. For deeper applications, a larger compressor should be used. When selecting a compressor, keep in mind that it takes about 1 CFM (Cubic Feet per Minute) to deliver 1 US Gallon per Minute (~4000 ml\/min) at 0 psi.<\/p>\n<p>Typically, an air compressor with a 4 to 5 CFM capacity will provide and maintain an output pressure of 100 psi. An oil-less compressor should always be used.<\/p>\n<p>For deeper sampling, a compressed air cylinder with a regulator is also an option. To get a representative sample, you may want to consider using nitrogen instead of air as your compressed gas source. A nitrogen cylinder is ideal as it is an inert, dry gas. It takes about 10 L of compressed gas to supply 1 L of sample water.<\/p>\n<h4><strong><a title=\"Groundwater Sampling Pump Electronic Control Units\" href=\"http:\/\/www.solinst.com\/products\/groundwater-samplers\/464-pneumatic-pump-control-units\/index.php\">Pump Control Units<\/a><\/strong><\/h4>\n<div id=\"attachment_846\" style=\"width: 210px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2010\/06\/Easy-to-Use-Electronic-Pump-Control-Unit.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-846\" class=\"wp-image-846 size-full\" title=\"Solinst 464 Electronic Pneumatic Pump Control Unit\" src=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2010\/06\/Easy-to-Use-Electronic-Pump-Control-Unit.jpg\" alt=\"Model 464 Electronic Pump Control Unit\" width=\"200\" height=\"213\" \/><\/a><p id=\"caption-attachment-846\" class=\"wp-caption-text\">464 Electronic Pump Control Unit<\/p><\/div>\n<p>With the proper pump control unit, Double Valve Pumps can achieve high purge rates, as well as low flow sampling rates. A control unit with preset flow rates, as well as the ability to adjust the drive\/vent cycle is an advantage to ensure you get the optimal sampling rate for your application.<\/p>\n<p>For help determining the proper drive and vent times, see our document <a href=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/407-bladder-pumps\/user-tips\/pump-tips.php\" target=\"_blank\" rel=\"noopener noreferrer\">Sampling Groundwater Using Bladder Pumps and Double Valve Pumps<\/a>.<\/p>\n<h4><strong>Pumping Depth<\/strong><\/h4>\n<p>Because you need a column of water in the drive line to push down on, to circulate water through the pump and up the sample line, the higher the water column present in the drive line &#8211; the better. A large water column makes the pump more efficient and less likely to over pressurize the system and allow air to enter the pump body. Having the pump submerged a minimum of a few meters below static water level is strongly recommended.<\/p>\n<p><strong>Note:<\/strong> If using a Double Valve Pump on a <a href=\"https:\/\/solinst.com\/products\/groundwater-samplers\/408-double-valve-pumps\/datasheet\/dedicated-and-portable-systems.php\" target=\"_blank\" rel=\"noopener\">tubing reel<\/a>, the <a href=\"https:\/\/solinst.com\/products\/level-measurement-devices\/101-power-winder\/101-power-winder.php\" target=\"_blank\" rel=\"noopener\">Solinst Power Winder<\/a> is a great option to add for efficiently and effortlessly lowering the pump to greater depths.\u00a0<\/p>\n<h4><strong>Well Recovery Rate<\/strong><\/h4>\n<p>Having more than a few meters of water in the drive line is also helpful in situations where you know your well is slow to recover. This helps prevent drive gas from entering the pump if your well has not fully recovered to static level before the next drive period. Knowing how quickly your well recovers, also helps you time your drive\/vent cycles properly.<\/p>\n<h4><strong>Purging<\/strong><\/h4>\n<p>If you are concerned about water from different levels mixing while the pump is being lowered, purging the pump a few times when the pump is at its desired sampling depth will eliminate any chemistry from other levels.<\/p>\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile is-image-fill has-background has-very-light-gray-background-color\"><figure class=\"wp-block-media-text__media\" style=\"background-image:url(https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2022\/03\/408-DVP-819x1024.jpg);background-position:50% 50%\"><img loading=\"lazy\" decoding=\"async\" width=\"819\" height=\"1024\" src=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2022\/03\/408-DVP-819x1024.jpg\" alt=\"solinst double valve pump for groundwater sampling\" class=\"wp-image-3874 size-full\" srcset=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2022\/03\/408-DVP-819x1024.jpg 819w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2022\/03\/408-DVP-240x300.jpg 240w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2022\/03\/408-DVP-768x960.jpg 768w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2022\/03\/408-DVP-624x780.jpg 624w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2022\/03\/408-DVP.jpg 1080w\" sizes=\"auto, (max-width: 819px) 100vw, 819px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"has-luminous-vivid-orange-color has-very-light-gray-background-color has-text-color has-background has-normal-font-size\">408 Double Valve Pumps are positive displacement, gas drive pumps providing high quality, consistent samples, and excellent VOC sample results. Pumps are available in stainless steel 5\/8&#8243; diameter and 1.66&#8243; diameter, as well as in PVC 1.66&#8243; diameter. Portable or dedicated versions are available. They can be fitted with packers to control groundwater flow and limit purge requirements. DVPs are easily disassembled for decontamination in minutes, without any tools.<br><a aria-label=\"Get a Quote! (opens in a new tab)\" href=\"https:\/\/www.solinst.com\/products\/groundwater-samplers\/408-double-valve-pumps\/get-quote.php\" target=\"_blank\" rel=\"noreferrer noopener\">Get a Quote!<\/a><\/p>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Double Valve Pumps can provide high quality, representative groundwater samples. However, to get the best quality samples from your pump, it is critical to understand how the Double Valve Pump works and how to operate it properly. Double Valve Pump Operating Principles: When a Double Valve Pump is submerged, hydrostatic pressure&#8230; <span class=\"continue-reading\"><a href=\"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/\" style=\"color: #666;\">Continue Reading &raquo;<\/a><\/span><\/p>\n","protected":false},"author":2,"featured_media":1657,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[450],"tags":[292,479],"class_list":["post-1651","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-low-flow-groundwater-sampling","tag-groundwater-sampling","tag-408-double-valve-pumps"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Getting the Best Quality Samples from Your Double Valve Pump<\/title>\n<meta name=\"description\" content=\"Double Valve Pumps provide high quality groundwater samples. However, to get the best quality samples, it is critical to understand how the Pump works.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Getting the Best Quality Samples from Your Double Valve Pump\" \/>\n<meta property=\"og:description\" content=\"Double Valve Pumps provide high quality groundwater samples. However, to get the best quality samples, it is critical to understand how the Pump works.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/\" \/>\n<meta property=\"og:site_name\" content=\"On The Level Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/solinstcanada\/\" \/>\n<meta property=\"article:published_time\" content=\"2020-01-13T18:51:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-07-17T16:00:57+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2016\/03\/408-PR.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"150\" \/>\n\t<meta property=\"og:image:height\" content=\"150\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Tricia Lane\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@solinstcanada\" \/>\n<meta name=\"twitter:site\" content=\"@solinstcanada\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tricia Lane\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/\"},\"author\":{\"name\":\"Tricia Lane\",\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/23ea69464d8e973f9c3ef8091ea2a94d\"},\"headline\":\"Getting The Best Quality Samples From Your Double Valve Pump\",\"datePublished\":\"2020-01-13T18:51:00+00:00\",\"dateModified\":\"2024-07-17T16:00:57+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/\"},\"wordCount\":960,\"image\":{\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2016\/03\/408-PR.jpg\",\"keywords\":[\"groundwater sampling\",\"408 double valve pumps\"],\"articleSection\":[\"Low Flow Groundwater Sampling\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/\",\"url\":\"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/\",\"name\":\"Getting the Best Quality Samples from Your Double Valve Pump\",\"isPartOf\":{\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2016\/03\/408-PR.jpg\",\"datePublished\":\"2020-01-13T18:51:00+00:00\",\"dateModified\":\"2024-07-17T16:00:57+00:00\",\"author\":{\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/23ea69464d8e973f9c3ef8091ea2a94d\"},\"description\":\"Double Valve Pumps provide high quality groundwater samples. However, to get the best quality samples, it is critical to understand how the Pump works.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/#primaryimage\",\"url\":\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2016\/03\/408-PR.jpg\",\"contentUrl\":\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2016\/03\/408-PR.jpg\",\"width\":150,\"height\":150},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.solinst.com\/onthelevel-news\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Getting The Best Quality Samples From Your Double Valve Pump\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/#website\",\"url\":\"https:\/\/www.solinst.com\/onthelevel-news\/\",\"name\":\"On The Level Blog\",\"description\":\"Water Monitoring News and Updates\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.solinst.com\/onthelevel-news\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/23ea69464d8e973f9c3ef8091ea2a94d\",\"name\":\"Tricia Lane\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g\",\"caption\":\"Tricia Lane\"},\"url\":\"https:\/\/www.solinst.com\/onthelevel-news\/author\/tricia-lane\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Getting the Best Quality Samples from Your Double Valve Pump","description":"Double Valve Pumps provide high quality groundwater samples. However, to get the best quality samples, it is critical to understand how the Pump works.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/","og_locale":"en_US","og_type":"article","og_title":"Getting the Best Quality Samples from Your Double Valve Pump","og_description":"Double Valve Pumps provide high quality groundwater samples. However, to get the best quality samples, it is critical to understand how the Pump works.","og_url":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/","og_site_name":"On The Level Blog","article_publisher":"https:\/\/www.facebook.com\/solinstcanada\/","article_published_time":"2020-01-13T18:51:00+00:00","article_modified_time":"2024-07-17T16:00:57+00:00","og_image":[{"width":150,"height":150,"url":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2016\/03\/408-PR.jpg","type":"image\/jpeg"}],"author":"Tricia Lane","twitter_card":"summary_large_image","twitter_creator":"@solinstcanada","twitter_site":"@solinstcanada","twitter_misc":{"Written by":"Tricia Lane","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/#article","isPartOf":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/"},"author":{"name":"Tricia Lane","@id":"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/23ea69464d8e973f9c3ef8091ea2a94d"},"headline":"Getting The Best Quality Samples From Your Double Valve Pump","datePublished":"2020-01-13T18:51:00+00:00","dateModified":"2024-07-17T16:00:57+00:00","mainEntityOfPage":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/"},"wordCount":960,"image":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2016\/03\/408-PR.jpg","keywords":["groundwater sampling","408 double valve pumps"],"articleSection":["Low Flow Groundwater Sampling"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/","url":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/","name":"Getting the Best Quality Samples from Your Double Valve Pump","isPartOf":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/#primaryimage"},"image":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2016\/03\/408-PR.jpg","datePublished":"2020-01-13T18:51:00+00:00","dateModified":"2024-07-17T16:00:57+00:00","author":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/23ea69464d8e973f9c3ef8091ea2a94d"},"description":"Double Valve Pumps provide high quality groundwater samples. However, to get the best quality samples, it is critical to understand how the Pump works.","breadcrumb":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/#primaryimage","url":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2016\/03\/408-PR.jpg","contentUrl":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2016\/03\/408-PR.jpg","width":150,"height":150},{"@type":"BreadcrumbList","@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/getting-the-best-quality-samples-from-your-double-valve-pump\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.solinst.com\/onthelevel-news\/"},{"@type":"ListItem","position":2,"name":"Getting The Best Quality Samples From Your Double Valve Pump"}]},{"@type":"WebSite","@id":"https:\/\/www.solinst.com\/onthelevel-news\/#website","url":"https:\/\/www.solinst.com\/onthelevel-news\/","name":"On The Level Blog","description":"Water Monitoring News and Updates","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solinst.com\/onthelevel-news\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/23ea69464d8e973f9c3ef8091ea2a94d","name":"Tricia Lane","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g","caption":"Tricia Lane"},"url":"https:\/\/www.solinst.com\/onthelevel-news\/author\/tricia-lane\/"}]}},"jetpack_featured_media_url":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2016\/03\/408-PR.jpg","_links":{"self":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts\/1651","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/comments?post=1651"}],"version-history":[{"count":16,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts\/1651\/revisions"}],"predecessor-version":[{"id":4209,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts\/1651\/revisions\/4209"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/media\/1657"}],"wp:attachment":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/media?parent=1651"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/categories?post=1651"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/tags?post=1651"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}