<style type="text/css">a[data-mtli~="mtli_filesize85343kB"]:after {content:" (853.43 kB)"}</style>{"id":2024,"date":"2017-06-01T14:00:37","date_gmt":"2017-06-01T18:00:37","guid":{"rendered":"http:\/\/www.solinst.com\/onthelevel-news\/?p=2024"},"modified":"2024-07-04T13:36:30","modified_gmt":"2024-07-04T17:36:30","slug":"barometric-compensation-and-the-importance-of-barometric-data","status":"publish","type":"post","link":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/","title":{"rendered":"Barometric Compensation And The Importance Of Barometric Data"},"content":{"rendered":"<div id=\"solid-grey-box\" class=\"floatRight\"><a href=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/technical-bulletins\/barometric-compensation.pdf\" class=\"mtli_attachment mtli_pdf\" data-mtli=\"mtli_filesize85343kB\" target=\"_blank\" rel=\"noopener noreferrer\">Download Technical Bulletin<\/a><\/div>\n<h2>Barometric Compensation<\/h2>\n<p><a title=\"Solinst Levelogger 5 Water Level Dataloggers\" href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/levelogger\/\" target=\"_blank\" rel=\"noopener noreferrer\">Leveloggers<\/a> measure total pressure (water column equivalent + barometric pressure). In order to accurately determine the true changes in water level only, barometric pressure fluctuations must be removed from the data.<span class=\"Apple-converted-space\">\u00a0<\/span><\/p>\n<p>The simplest method to accomplish this is by the use of a <a title=\"Solinst Barologger 5 Barometric Dataloggers\" href=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/levelogger\/datasheet\/barometric-compensation.php\" target=\"_blank\" rel=\"noopener noreferrer\">Barologger<\/a> suspended above high water level in one well on site. The approximate site compensation coverage is 30 km (20 miles). This records ambient barometric fluctuations over time and allows quick and accurate barometric compensation using the data files from both the Barologger and any Leveloggers in the area.<span class=\"Apple-converted-space\">\u00a0<\/span><\/p>\n<div id=\"attachment_3266\" style=\"width: 635px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3266\" class=\"wp-image-3266 size-large\" title=\"Levelogger 5 and Barologger 5 Dataloggers\" src=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/04\/L5-Baro5-1024x341.jpg\" alt=\"levelogger 5 and barologger 5 dataloggers\" width=\"625\" height=\"208\" srcset=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/04\/L5-Baro5-1024x341.jpg 1024w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/04\/L5-Baro5-300x100.jpg 300w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/04\/L5-Baro5-768x256.jpg 768w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/04\/L5-Baro5-624x208.jpg 624w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/04\/L5-Baro5.jpg 1200w\" sizes=\"auto, (max-width: 625px) 100vw, 625px\" \/><p id=\"caption-attachment-3266\" class=\"wp-caption-text\">Levelogger 5 and Barologger 5 Dataloggers<\/p><\/div>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-large wp-image-3371 alignleft\" title=\"Solinst Levelogger 5 and Barologger 5 Installed on Direct Read Cables\" src=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/3001-Levelogger5-Barologger5-DirectReadDeployment-310x1024.jpg\" alt=\"solinst levelogger 5 and barologger 5 installed on direct read cables\" width=\"310\" height=\"1024\" srcset=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/3001-Levelogger5-Barologger5-DirectReadDeployment-310x1024.jpg 310w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/3001-Levelogger5-Barologger5-DirectReadDeployment-91x300.jpg 91w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/3001-Levelogger5-Barologger5-DirectReadDeployment-465x1536.jpg 465w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/3001-Levelogger5-Barologger5-DirectReadDeployment.jpg 604w\" sizes=\"auto, (max-width: 310px) 100vw, 310px\" \/>The algorithms programmed into the Barologger are strictly for use in air, making this instrument extremely accurate. The barometric data is then used, along with a software Data Wizard, to compensate the Levelogger data and provide true water level readings. To increase the accuracy of barometric compensation data, it is recommended the Barologger and Leveloggers be programmed with the same recording times.<span class=\"Apple-converted-space\">\u00a0<\/span><\/p>\n<p>Once the Levelogger and Barologger data is downloaded to Solinst Levelogger Software, the Data Wizard can be used to barometrically compensate the data, and adjust it to depth measurements. Multiple Levelogger files can be barometrically compensated at once using one Barologger file.<span class=\"Apple-converted-space\">\u00a0<\/span><\/p>\n<p>You can view your data directly, or it can be exported in a standard .csv or .xml format for use in any hydrologic software for further analysis and interpretation.<\/p>\n<p>Note: If you did not have a Barologger on site, further on in the blog post there is a discussion on manual barometric compensation.<\/p>\n<h2>Barometric Data<\/h2>\n<p><span style=\"font-size: inherit;\">When analyzing barometric data it is important to keep in mind that storm events commonly reduce total atmospheric pressure by about 1.7% from pre-existing high pressure conditions. 1.7% converts to approximately 0.2 m or 0.6 ft of water level equivalent barometric fluctuation, see graphic below.<\/span><\/p>\n<p><span style=\"font-size: inherit;\">Raw data can be useful information for calculating <\/span><a style=\"font-size: inherit;\" title=\"Understanding Barometric Efficiency\" href=\"\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/operating-instructions\/user-guide\/10-levelogger-installation-maintenance\/10-1-3-1-barometric-efficiency.php\" target=\"_blank\" rel=\"noopener noreferrer\">barometric efficiency<\/a><span style=\"font-size: inherit;\">, which can be very significant in tight, deep, confined aquifers, when the investigator has a choice not to compensate the readings. <\/span><\/p>\n<p><span style=\"font-size: inherit;\">The use of vented cable technology to provide barometric compensation can be suitable for shallow applications, however, vented pressure sensors assume 100% barometric efficiency, which is a fair assumption in shallow conditions, but the lack of barometric data can make it difficult to confirm\u00a0if the vented transducer is recording correctly. <\/span><\/p>\n<p><span style=\"font-size: inherit;\">It was found that, for many applications, recorded barometric data provided the necessary barometric compensation data our clients require. The absolute pressure method also provides the separate barometric data of local air pressure and ambient air temperature, which can be analyzed to ensure the Levelogger transducer is recording properly.<\/span><\/p>\n<div id=\"attachment_3372\" style=\"width: 1210px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3372\" class=\"wp-image-3372\" title=\"An Example of How a Storm Event Can Affect Barometric Pressure\" src=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/Barometric-Pressure-Fluctuation-Graph.jpg\" alt=\"an example of how a storm event can affect barometric pressure\" width=\"1200\" height=\"366\" srcset=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/Barometric-Pressure-Fluctuation-Graph.jpg 988w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/Barometric-Pressure-Fluctuation-Graph-300x91.jpg 300w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/Barometric-Pressure-Fluctuation-Graph-768x234.jpg 768w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/Barometric-Pressure-Fluctuation-Graph-624x190.jpg 624w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><p id=\"caption-attachment-3372\" class=\"wp-caption-text\">An Example of How a Storm Event Can Affect Barometric Pressure<\/p><\/div>\n<h2>Manual Barometric Compensation<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright size-large wp-image-3374\" title=\"Levelogger 5 Installed On A Direct Read Cable\" src=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/3001-Levelogger5-EdgeDirectRead-Deployment-311x1024.jpg\" alt=\"levelogger 5 installed on a direct read cable\" width=\"311\" height=\"1024\" srcset=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/3001-Levelogger5-EdgeDirectRead-Deployment-311x1024.jpg 311w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/3001-Levelogger5-EdgeDirectRead-Deployment-91x300.jpg 91w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/3001-Levelogger5-EdgeDirectRead-Deployment-467x1536.jpg 467w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/3001-Levelogger5-EdgeDirectRead-Deployment.jpg 601w\" sizes=\"auto, (max-width: 311px) 100vw, 311px\" \/><\/p>\n<p>If an on-site Barologger is not available, your data can be compensated using alternate barometric data (e.g. from a local weather station).<\/p>\n<p>To accomplish an accurate manual barometric compensation, the atmospheric pressure station should <strong>not be greater than 30 km (20 miles) away<\/strong>.<span class=\"Apple-converted-space\">\u00a0<\/span><\/p>\n<p>You should <strong>include the elevation difference between the weather station and Levelogger<\/strong> in your calculation (Step 1 below). As elevation increases, barometric pressure decreases at a rate of approximately 1.21\/1000 ft or meters. This rate can be shown as Elevation\/826.<\/p>\n<p>In addition, <strong>the date and time of the barometric data should cover the range of data collected<\/strong> by the Levelogger.<span class=\"Apple-converted-space\">\u00a0<\/span><\/p>\n<p>Next, your <strong>Levelogger data and barometric data must be in the same units<\/strong><span class=\"Apple-converted-space\">\u00a0 <\/span>(Step 2 below), and assure that any offsets or normalization values are accounted for.<span class=\"Apple-converted-space\">\u00a0<\/span><\/p>\n<p>Although not shown in our example, it is also important to remember that weather station barometric data will often contain a different offset or normalization. Manual data conversion and barometric compensation should account for any variation of the normalization or offset used between the barometric data sourced and Solinst Leveloggers.<\/p>\n<p><strong>Once the final calculated barometric pressure values are obtained, they are subtracted from the Levelogger data set<\/strong> (Step 3 below). Since the Levelogger data can be easily exported as a .csv<span class=\"Apple-converted-space\">\u00a0 <\/span>or .xml file using Levelogger Software, all manual corrections can be performed in external programs.<\/p>\n<div id=\"attachment_3376\" style=\"width: 680px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3376\" class=\"size-full wp-image-3376\" title=\"Pressure Conversion Factors Chart\" src=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/PressureConversionFactorsChart.jpg\" alt=\"pressure conversion factors chart\" width=\"670\" height=\"205\" srcset=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/PressureConversionFactorsChart.jpg 670w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/PressureConversionFactorsChart-300x92.jpg 300w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/PressureConversionFactorsChart-624x191.jpg 624w\" sizes=\"auto, (max-width: 670px) 100vw, 670px\" \/><p id=\"caption-attachment-3376\" class=\"wp-caption-text\">Water Column Equivalents to Common Barometric Units<\/p><\/div>\n<h3>Example Calculation<\/h3>\n<p><strong>1) Elevation Difference:<\/strong><br \/>\nElevation of Levelogger &#8211; Elevation of Weather Station \/ 826<br \/>\n= 800 ft (ASL) &#8211; 500 ft (ASL) \/ 826<br \/>\n= +300 \/ 826<br \/>\n= +0.3632 ft<br \/>\nTherefore, add <span style=\"color: #008000;\">0.3632 ft<\/span> to your Levelogger data set<\/p>\n<p><strong>2) Conversion from psi to feet of water column equivalent<\/strong><br \/>\n15 psi x *2.30666 ft\/psi = 34.5999 ft head<br \/>\nTherefore, subtract <span style=\"color: #ff0000;\">34.5999 ft<\/span> from your Levelogger data<br \/>\n(*<em>value denotes pressure conversion factor from table above)<\/em><\/p>\n<p><strong>3) Manual Barometric Compensation<br \/>\n<\/strong>Where the uncompensated Levelogger 5 data is a water level of <strong>41.1700 ft<\/strong>, from the calculations above, the manual compensation would be:<br \/>\n(<strong>41.1700 ft<\/strong> +<span style=\"color: #008000;\"> 0.3632 ft<\/span>) \u2013 <span style=\"color: #ff0000;\">34.5999<span class=\"Apple-converted-space\">\u00a0 <\/span>ft<\/span> = <strong>6.9333 ft<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Barometric Compensation Leveloggers measure total pressure (water column equivalent + barometric pressure). In order to accurately determine the true changes in water level only, barometric pressure fluctuations must be removed from the data.  The simplest method to accomplish this is by the use of a Barologger suspended above high water level in\u2026 <span class=\"continue-reading\"><a href=\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/\" style=\"color: #666;\">Continue Reading &raquo;<\/a><\/span><\/p>\n","protected":false},"author":2,"featured_media":3276,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[454],"tags":[12,56,88,194,298,409,456,461],"class_list":["post-2024","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-water-level-datalogging","tag-barometric-compensation","tag-absolute-pressure","tag-levelogger-data","tag-barometric-pressure","tag-barometric-efficiency","tag-absolute-pressure-transducer","tag-3001-levelogger","tag-3001-barologger"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Importance of Barometric Compensation &amp; Barometric Data<\/title>\n<meta name=\"description\" content=\"Barologger data not only provides accurate barometric compensation of Levelogger data, it can provide insight on site conditions and instrument accuracy.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Importance of Barometric Compensation &amp; Barometric Data\" \/>\n<meta property=\"og:description\" content=\"Barologger data not only provides accurate barometric compensation of Levelogger data, it can provide insight on site conditions and instrument accuracy.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/\" \/>\n<meta property=\"og:site_name\" content=\"On The Level Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/solinstcanada\/\" \/>\n<meta property=\"article:published_time\" content=\"2017-06-01T18:00:37+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-07-04T17:36:30+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/L5-Baro5-Thumb-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"150\" \/>\n\t<meta property=\"og:image:height\" content=\"150\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Tricia Lane\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/Barometric-Pressure-Fluctuation-Graph.jpg\" \/>\n<meta name=\"twitter:creator\" content=\"@solinstcanada\" \/>\n<meta name=\"twitter:site\" content=\"@solinstcanada\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tricia Lane\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/barometric-compensation-and-the-importance-of-barometric-data\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/barometric-compensation-and-the-importance-of-barometric-data\\\/\"},\"author\":{\"name\":\"Tricia Lane\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/#\\\/schema\\\/person\\\/23ea69464d8e973f9c3ef8091ea2a94d\"},\"headline\":\"Barometric Compensation And The Importance Of Barometric Data\",\"datePublished\":\"2017-06-01T18:00:37+00:00\",\"dateModified\":\"2024-07-04T17:36:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/barometric-compensation-and-the-importance-of-barometric-data\\\/\"},\"wordCount\":782,\"image\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/barometric-compensation-and-the-importance-of-barometric-data\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/wp-content\\\/uploads\\\/2017\\\/06\\\/L5-Baro5-Thumb-1.jpg\",\"keywords\":[\"barometric compensation\",\"absolute pressure\",\"levelogger data\",\"barometric pressure\",\"barometric efficiency\",\"absolute pressure transducer\",\"3001 levelogger\",\"3001 barologger\"],\"articleSection\":[\"Water Level Datalogging\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/barometric-compensation-and-the-importance-of-barometric-data\\\/\",\"url\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/barometric-compensation-and-the-importance-of-barometric-data\\\/\",\"name\":\"Importance of Barometric Compensation & Barometric Data\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/barometric-compensation-and-the-importance-of-barometric-data\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/barometric-compensation-and-the-importance-of-barometric-data\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/wp-content\\\/uploads\\\/2017\\\/06\\\/L5-Baro5-Thumb-1.jpg\",\"datePublished\":\"2017-06-01T18:00:37+00:00\",\"dateModified\":\"2024-07-04T17:36:30+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/#\\\/schema\\\/person\\\/23ea69464d8e973f9c3ef8091ea2a94d\"},\"description\":\"Barologger data not only provides accurate barometric compensation of Levelogger data, it can provide insight on site conditions and instrument accuracy.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/barometric-compensation-and-the-importance-of-barometric-data\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/barometric-compensation-and-the-importance-of-barometric-data\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/barometric-compensation-and-the-importance-of-barometric-data\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/wp-content\\\/uploads\\\/2017\\\/06\\\/L5-Baro5-Thumb-1.jpg\",\"contentUrl\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/wp-content\\\/uploads\\\/2017\\\/06\\\/L5-Baro5-Thumb-1.jpg\",\"width\":150,\"height\":150},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/water-level-monitoring\\\/water-level-datalogging\\\/barometric-compensation-and-the-importance-of-barometric-data\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Barometric Compensation And The Importance Of Barometric Data\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/#website\",\"url\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/\",\"name\":\"On The Level Blog\",\"description\":\"Water Monitoring News and Updates\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/#\\\/schema\\\/person\\\/23ea69464d8e973f9c3ef8091ea2a94d\",\"name\":\"Tricia Lane\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g\",\"caption\":\"Tricia Lane\"},\"url\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/author\\\/tricia-lane\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Importance of Barometric Compensation & Barometric Data","description":"Barologger data not only provides accurate barometric compensation of Levelogger data, it can provide insight on site conditions and instrument accuracy.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/","og_locale":"en_US","og_type":"article","og_title":"Importance of Barometric Compensation & Barometric Data","og_description":"Barologger data not only provides accurate barometric compensation of Levelogger data, it can provide insight on site conditions and instrument accuracy.","og_url":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/","og_site_name":"On The Level Blog","article_publisher":"https:\/\/www.facebook.com\/solinstcanada\/","article_published_time":"2017-06-01T18:00:37+00:00","article_modified_time":"2024-07-04T17:36:30+00:00","og_image":[{"width":150,"height":150,"url":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/L5-Baro5-Thumb-1.jpg","type":"image\/jpeg"}],"author":"Tricia Lane","twitter_card":"summary_large_image","twitter_image":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/Barometric-Pressure-Fluctuation-Graph.jpg","twitter_creator":"@solinstcanada","twitter_site":"@solinstcanada","twitter_misc":{"Written by":"Tricia Lane","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/#article","isPartOf":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/"},"author":{"name":"Tricia Lane","@id":"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/23ea69464d8e973f9c3ef8091ea2a94d"},"headline":"Barometric Compensation And The Importance Of Barometric Data","datePublished":"2017-06-01T18:00:37+00:00","dateModified":"2024-07-04T17:36:30+00:00","mainEntityOfPage":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/"},"wordCount":782,"image":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/L5-Baro5-Thumb-1.jpg","keywords":["barometric compensation","absolute pressure","levelogger data","barometric pressure","barometric efficiency","absolute pressure transducer","3001 levelogger","3001 barologger"],"articleSection":["Water Level Datalogging"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/","url":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/","name":"Importance of Barometric Compensation & Barometric Data","isPartOf":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/#primaryimage"},"image":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/L5-Baro5-Thumb-1.jpg","datePublished":"2017-06-01T18:00:37+00:00","dateModified":"2024-07-04T17:36:30+00:00","author":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/23ea69464d8e973f9c3ef8091ea2a94d"},"description":"Barologger data not only provides accurate barometric compensation of Levelogger data, it can provide insight on site conditions and instrument accuracy.","breadcrumb":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/#primaryimage","url":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/L5-Baro5-Thumb-1.jpg","contentUrl":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/L5-Baro5-Thumb-1.jpg","width":150,"height":150},{"@type":"BreadcrumbList","@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/water-level-datalogging\/barometric-compensation-and-the-importance-of-barometric-data\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.solinst.com\/onthelevel-news\/"},{"@type":"ListItem","position":2,"name":"Barometric Compensation And The Importance Of Barometric Data"}]},{"@type":"WebSite","@id":"https:\/\/www.solinst.com\/onthelevel-news\/#website","url":"https:\/\/www.solinst.com\/onthelevel-news\/","name":"On The Level Blog","description":"Water Monitoring News and Updates","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solinst.com\/onthelevel-news\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/23ea69464d8e973f9c3ef8091ea2a94d","name":"Tricia Lane","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g","caption":"Tricia Lane"},"url":"https:\/\/www.solinst.com\/onthelevel-news\/author\/tricia-lane\/"}]}},"jetpack_featured_media_url":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/06\/L5-Baro5-Thumb-1.jpg","_links":{"self":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts\/2024","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/comments?post=2024"}],"version-history":[{"count":19,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts\/2024\/revisions"}],"predecessor-version":[{"id":4189,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts\/2024\/revisions\/4189"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/media\/3276"}],"wp:attachment":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/media?parent=2024"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/categories?post=2024"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/tags?post=2024"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}