{"id":2234,"date":"2017-03-01T10:22:26","date_gmt":"2017-03-01T15:22:26","guid":{"rendered":"https:\/\/www.solinst.com\/onthelevel-news\/?p=2234"},"modified":"2023-04-06T15:51:09","modified_gmt":"2023-04-06T19:51:09","slug":"manual-or-automatic-level-temperature-conductivity-monitoring","status":"publish","type":"post","link":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/","title":{"rendered":"Manual Or Automatic Level, Temperature &#038; Conductivity Monitoring"},"content":{"rendered":"<p>Conductivity is a parameter that is very useful as a general indication of contamination and salinity levels in water, thus it may be used as a pre-screening tool to help avoid costly laboratory analyses. Conductivity can also be used for measuring and monitoring the impact of pollutants such as road salts, agricultural and highway runoff, chemical spills, and saltwater intrusion on water supplies and aquatic ecosystems.<\/p>\n<p>As conductivity measurements are required to be temperature compensated, and water level data is always necessary, Solinst offers two tools that can provide this information, using either manual methods or by datalogging.<\/p>\n<h2>Depth-Discrete Temperature &amp; Conductivity Monitoring<\/h2>\n<p>The <a title=\"Solinst TLC Meter Water Level: Water Temperature: Water Conductivity Profiling\" href=\"https:\/\/www.solinst.com\/products\/level-measurement-devices\/107-tlc-meter\/\" target=\"_blank\" rel=\"noopener noreferrer\">Solinst TLC Meter<\/a> has been specifically designed to be an easy-to-use, economical temperature and conductivity profiler and water level meter for wells and surface water applications.<\/p>\n<p>It is excellent for detecting contaminant inflows, monitoring salinity levels, and obtaining early warnings of changes in water quality at landfills and industrial sites.<\/p>\n<div id=\"attachment_2236\" style=\"width: 360px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-Front-View-DS.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2236\" class=\"wp-image-2236\" title=\"Solinst Model 107 TLC Meter\" src=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-Front-View-DS-229x300.jpg\" alt=\"solinst model 107 tlc meter\" width=\"350\" height=\"459\" srcset=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-Front-View-DS-229x300.jpg 229w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-Front-View-DS-781x1024.jpg 781w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-Front-View-DS-624x818.jpg 624w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-Front-View-DS.jpg 1200w\" sizes=\"auto, (max-width: 350px) 100vw, 350px\" \/><\/a><p id=\"caption-attachment-2236\" class=\"wp-caption-text\">Solinst Model 107 TLC Meter<\/p><\/div>\n<p>The TLC Meter features a \u2018smart\u2019 probe with platinum electrodes, providing accurate temperature and conductivity measurements from 0\u201380,000 \u00b5S. The 19 mm (3\/4&#8243;) diameter probe measures electrical conductivity that has been standardized to 25 degrees Celsius, that displays as Specific Conductance.<\/p>\n<div id=\"attachment_2239\" style=\"width: 510px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-Conductivity-in-Wells.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2239\" class=\"wp-image-2239\" title=\"Water Level Temperature and Conductivity Profiling Using the TLC Meter\" src=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-Conductivity-in-Wells-807x1024.jpg\" alt=\"water level temperature and conductivity profiling using the tlc meter\" width=\"500\" height=\"634\" srcset=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-Conductivity-in-Wells-807x1024.jpg 807w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-Conductivity-in-Wells-236x300.jpg 236w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-Conductivity-in-Wells-624x792.jpg 624w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-Conductivity-in-Wells.jpg 1287w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><p id=\"caption-attachment-2239\" class=\"wp-caption-text\">Water Level, Temperature &amp; Conductivity Profiling Using the TLC Meter<\/p><\/div>\n<p>The probe is attached to high quality flat tape for depth readings, which is indicated by a light and buzzer. The tape is accurately laser-marked each millimeter or 1\/100 ft, in lengths up to 300 m or 1000 ft. The probe and tape are mounted on a sturdy reel making operation easy. Conductivity and temperature measurements are displayed on an LCD display.<\/p>\n<p><strong>Note:<\/strong> a <a href=\"https:\/\/solinst.com\/products\/level-measurement-devices\/101-power-winder\/101-power-winder.php\" target=\"_blank\" rel=\"noopener\">Power Winder<\/a> can be added to a TLC Meter to help with the lowering and raising of longer tape lengths.<\/p>\n<h2>Add Conductivity to Your Level &amp; Temperature Monitoring Program<\/h2>\n<p>The <a title=\"Solinst Levelogger 5 LTC Water Conductivity Dataloggers\" href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/3001-levelogger-series\/ltc-levelogger\/\" target=\"_blank\" rel=\"noopener noreferrer\">Levelogger 5 LTC<\/a> has been specifically designed for long-term monitoring of conductivity changes over time, especially salt-water intrusion studies. The Levelogger 5 LTC has a compact, waterproof, low maintenance, and durable design.<\/p>\n<div id=\"attachment_3220\" style=\"width: 635px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3220\" class=\"size-large wp-image-3220\" src=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/3001-LTC-5-PointingLeft-10in-1024x109.jpg\" alt=\"Levelogger 5 LTC Water Level, Temperature and Conductivity Datalogger\" width=\"625\" height=\"67\" srcset=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/3001-LTC-5-PointingLeft-10in-1024x109.jpg 1024w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/3001-LTC-5-PointingLeft-10in-300x32.jpg 300w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/3001-LTC-5-PointingLeft-10in-768x82.jpg 768w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/3001-LTC-5-PointingLeft-10in-624x67.jpg 624w, https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/3001-LTC-5-PointingLeft-10in.jpg 1200w\" sizes=\"auto, (max-width: 625px) 100vw, 625px\" \/><p id=\"caption-attachment-3220\" class=\"wp-caption-text\">Model 3001 Levelogger 5 LTC Datalogger<\/p><\/div>\n<p>The Levelogger 5 LTC allows accurate datalogging of conductivity along with temperature and water levels as often as every second. The conductivity sensor is a 4-electrode platinum sensor, with auto-ranging capabilities from 0\u2013100,000 \u00b5S and calibration from 50\u201380,000 \u00b5S. It measures electrical conductivity that has been standardized to 25 degrees Celsius, i.e.: Specific Conductance.<\/p>\n<div id=\"attachment_2237\" style=\"width: 710px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-Tech-Bulletin-Graph.gif\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2237\" class=\"wp-image-2237\" title=\"LTC Levelogger Water Conductivity Data\" src=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-Tech-Bulletin-Graph.gif\" alt=\"ltc levelogger water conductivity data\" width=\"700\" height=\"541\"><\/a><p id=\"caption-attachment-2237\" class=\"wp-caption-text\">Levelogger 5 LTC Water Level, Temperature &amp; Conductivity Monitoring Data<\/p><\/div>\n<p>The Levelogger 5 LTC combines a datalogger, 8-year battery, memory for 100,000 sets of readings, pressure transducer, and temperature and conductivity sensors in a small 22 mm x 208 mm (7\/8&#8243; x 8.2&#8243;) housing. It is simple to deploy, calibrate, and program. Data management is easy using Levelogger Software.<\/p>\n<p>To easily create a network of monitoring wells, the Levelogger 5 LTC can be integrated into a <a href=\"https:\/\/www.solinst.com\/products\/dataloggers-and-telemetry\/solinst-telemetry-systems\/9500-levelsender\/levelsender.php\" target=\"_blank\" rel=\"noopener noreferrer\">Solinst Telemetry System<\/a>, which allows convenient access to remote, real-time data.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Conductivity is a parameter that is very useful as a general indication of contamination and salinity levels in water, thus it may be used as a pre-screening tool to help avoid costly laboratory analyses. Conductivity can also be used for measuring and monitoring the impact of pollutants such as road salts, agricultural and highway runoff,\u2026 <span class=\"continue-reading\"><a href=\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/\" style=\"color: #666;\">Continue Reading &raquo;<\/a><\/span><\/p>\n","protected":false},"author":2,"featured_media":2242,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[453],"tags":[426,427,428,429,430,444,456,473],"class_list":["post-2234","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-water-level-monitoring","tag-ltc-levelogger-edge","tag-conductivity-monitoring","tag-conductivity-profiling","tag-temperature-monitoring","tag-temperature-profiling","tag-water-conductivity-datalogging","tag-3001-levelogger","tag-107-tlc-meter"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Manual or Automatic Level, Temp. &amp; Conductivity Monitoring<\/title>\n<meta name=\"description\" content=\"Solinst offers the manual TLC Meter and automated LTC Levelogger Edge datalogger for water level, temperature &amp; conductivity monitoring.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Manual or Automatic Level, Temp. &amp; Conductivity Monitoring\" \/>\n<meta property=\"og:description\" content=\"Solinst offers the manual TLC Meter and automated LTC Levelogger Edge datalogger for water level, temperature &amp; conductivity monitoring.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/\" \/>\n<meta property=\"og:site_name\" content=\"On The Level Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/solinstcanada\/\" \/>\n<meta property=\"article:published_time\" content=\"2017-03-01T15:22:26+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-04-06T19:51:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-profile-thumb.png\" \/>\n\t<meta property=\"og:image:width\" content=\"150\" \/>\n\t<meta property=\"og:image:height\" content=\"155\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Tricia Lane\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@solinstcanada\" \/>\n<meta name=\"twitter:site\" content=\"@solinstcanada\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tricia Lane\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/\"},\"author\":{\"name\":\"Tricia Lane\",\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/23ea69464d8e973f9c3ef8091ea2a94d\"},\"headline\":\"Manual Or Automatic Level, Temperature &#038; Conductivity Monitoring\",\"datePublished\":\"2017-03-01T15:22:26+00:00\",\"dateModified\":\"2023-04-06T19:51:09+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/\"},\"wordCount\":495,\"image\":{\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-profile-thumb.png\",\"keywords\":[\"ltc levelogger edge\",\"conductivity monitoring\",\"conductivity profiling\",\"temperature monitoring\",\"temperature profiling\",\"water conductivity datalogging\",\"3001 levelogger\",\"107 tlc meter\"],\"articleSection\":[\"Water Level Monitoring\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/\",\"url\":\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/\",\"name\":\"Manual or Automatic Level, Temp. & Conductivity Monitoring\",\"isPartOf\":{\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-profile-thumb.png\",\"datePublished\":\"2017-03-01T15:22:26+00:00\",\"dateModified\":\"2023-04-06T19:51:09+00:00\",\"author\":{\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/23ea69464d8e973f9c3ef8091ea2a94d\"},\"description\":\"Solinst offers the manual TLC Meter and automated LTC Levelogger Edge datalogger for water level, temperature & conductivity monitoring.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/#primaryimage\",\"url\":\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-profile-thumb.png\",\"contentUrl\":\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-profile-thumb.png\",\"width\":150,\"height\":155},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.solinst.com\/onthelevel-news\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Manual Or Automatic Level, Temperature &#038; Conductivity Monitoring\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/#website\",\"url\":\"https:\/\/www.solinst.com\/onthelevel-news\/\",\"name\":\"On The Level Blog\",\"description\":\"Water Monitoring News and Updates\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.solinst.com\/onthelevel-news\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/23ea69464d8e973f9c3ef8091ea2a94d\",\"name\":\"Tricia Lane\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g\",\"caption\":\"Tricia Lane\"},\"url\":\"https:\/\/www.solinst.com\/onthelevel-news\/author\/tricia-lane\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Manual or Automatic Level, Temp. & Conductivity Monitoring","description":"Solinst offers the manual TLC Meter and automated LTC Levelogger Edge datalogger for water level, temperature & conductivity monitoring.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/","og_locale":"en_US","og_type":"article","og_title":"Manual or Automatic Level, Temp. & Conductivity Monitoring","og_description":"Solinst offers the manual TLC Meter and automated LTC Levelogger Edge datalogger for water level, temperature & conductivity monitoring.","og_url":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/","og_site_name":"On The Level Blog","article_publisher":"https:\/\/www.facebook.com\/solinstcanada\/","article_published_time":"2017-03-01T15:22:26+00:00","article_modified_time":"2023-04-06T19:51:09+00:00","og_image":[{"width":150,"height":155,"url":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-profile-thumb.png","type":"image\/png"}],"author":"Tricia Lane","twitter_card":"summary_large_image","twitter_creator":"@solinstcanada","twitter_site":"@solinstcanada","twitter_misc":{"Written by":"Tricia Lane","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/#article","isPartOf":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/"},"author":{"name":"Tricia Lane","@id":"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/23ea69464d8e973f9c3ef8091ea2a94d"},"headline":"Manual Or Automatic Level, Temperature &#038; Conductivity Monitoring","datePublished":"2017-03-01T15:22:26+00:00","dateModified":"2023-04-06T19:51:09+00:00","mainEntityOfPage":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/"},"wordCount":495,"image":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-profile-thumb.png","keywords":["ltc levelogger edge","conductivity monitoring","conductivity profiling","temperature monitoring","temperature profiling","water conductivity datalogging","3001 levelogger","107 tlc meter"],"articleSection":["Water Level Monitoring"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/","url":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/","name":"Manual or Automatic Level, Temp. & Conductivity Monitoring","isPartOf":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/#primaryimage"},"image":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-profile-thumb.png","datePublished":"2017-03-01T15:22:26+00:00","dateModified":"2023-04-06T19:51:09+00:00","author":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/23ea69464d8e973f9c3ef8091ea2a94d"},"description":"Solinst offers the manual TLC Meter and automated LTC Levelogger Edge datalogger for water level, temperature & conductivity monitoring.","breadcrumb":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/#primaryimage","url":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-profile-thumb.png","contentUrl":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-profile-thumb.png","width":150,"height":155},{"@type":"BreadcrumbList","@id":"https:\/\/www.solinst.com\/onthelevel-news\/water-level-monitoring\/manual-or-automatic-level-temperature-conductivity-monitoring\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.solinst.com\/onthelevel-news\/"},{"@type":"ListItem","position":2,"name":"Manual Or Automatic Level, Temperature &#038; Conductivity Monitoring"}]},{"@type":"WebSite","@id":"https:\/\/www.solinst.com\/onthelevel-news\/#website","url":"https:\/\/www.solinst.com\/onthelevel-news\/","name":"On The Level Blog","description":"Water Monitoring News and Updates","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solinst.com\/onthelevel-news\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/23ea69464d8e973f9c3ef8091ea2a94d","name":"Tricia Lane","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/9c522fb6f0f99d65b63635608c87652db187b06dacb08de437026375759ee7e3?s=96&d=mm&r=g","caption":"Tricia Lane"},"url":"https:\/\/www.solinst.com\/onthelevel-news\/author\/tricia-lane\/"}]}},"jetpack_featured_media_url":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2017\/03\/107-profile-thumb.png","_links":{"self":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts\/2234","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/comments?post=2234"}],"version-history":[{"count":7,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts\/2234\/revisions"}],"predecessor-version":[{"id":4079,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts\/2234\/revisions\/4079"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/media\/2242"}],"wp:attachment":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/media?parent=2234"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/categories?post=2234"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/tags?post=2234"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}