{"id":742,"date":"2010-06-09T16:03:06","date_gmt":"2010-06-09T20:03:06","guid":{"rendered":"http:\/\/www.solinst.com\/onthelevel-news\/?p=742"},"modified":"2017-05-04T16:31:16","modified_gmt":"2017-05-04T20:31:16","slug":"bladder-pumps-exceed-sampling-criteria","status":"publish","type":"post","link":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/bladder-pumps-exceed-sampling-criteria\/","title":{"rendered":"Bladder Pumps Exceed Sampling Criteria"},"content":{"rendered":"<p>A nuclear power facility in England has an extensive groundwater monitoring well network that requires regular sampling. Golder Associates, the project team who developed the network, wished to update their sampling equipment and protocols to improve efficiency, while maintaining accuracy and high safety standards. A set of objectives was defined to help determine the ideal solution:<\/p>\n<ul>\n<li>Minimize purge volumes and wastewater disposal<\/li>\n<li>Sampling possible by one technician<\/li>\n<li>Economical and easy to maintain<\/li>\n<li>Control flow rates to lessen spillage<\/li>\n<li>Ensure high quality of sample<\/li>\n<\/ul>\n<p>Upon review,\u00a0<a style=\"color: #0e2f77;\" title=\"Solinst Integra Bladder Pumps\" href=\"\/products\/groundwater-samplers\/407-bladder-pumps\/index.php\"><strong>Solinst Bladder Pumps<\/strong><\/a>\u00a0were selected, as they are able meet all of the outlined objectives. With the use of a Solinst Pump Controller, the pumps can be easily adjusted to provide a continuous output of 100 ml\/min or less. Over 120 Bladder Pumps were purchased for use at the facility.<\/p>\n<p>At a low level nuclear waste processing facility located in the same region, more than 50 monitoring wells require regular groundwater sampling. Solinst Bladder Pumps were again selected for the job. Initially, twenty-five dedicated pumps were installed in selected wells, and a small portable version was purchased for convenient sampling from other wells. With the success of the initial pump installations, numerous additional pumps have been installed since.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" src=\"\/onthelevel\/spring2010\/images\/Bladder-Pumps-Used-at-Sensitive-Sites.jpg\" alt=\"solinst bladder pump groundwater sampling pumps image\" width=\"350\" height=\"362\" \/><\/p>\n<p>Both these locations adhere to very high requirements in terms of operational standards in order to comply with a demanding combination of technical, disposal, and safety criteria. Using Solinst Bladder Pumps, the project teams successfully introduced low flow sampling protocols, which allowed them to meet all of their goals and provided numerous advantages, including:<\/p>\n<ul>\n<li>Reduced purge volumes<\/li>\n<li>Less time required to obtain each sample<\/li>\n<li>More representative samples<\/li>\n<li>Improved quality control<\/li>\n<li>Cost savings<\/li>\n<\/ul>\n<p><em>Thanks is extended to Waterra UK for providing expert technical support and field assistance to the project teams tasked with instrumenting these two critically sensitive locations.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>A nuclear power facility in England has an extensive groundwater monitoring well network that requires regular sampling. Golder Associates, the project team who developed the network, wished to update their sampling equipment and protocols to improve efficiency, while maintaining accuracy and high safety standards. A set of objectives was defined to help determine the ideal&#8230; <span class=\"continue-reading\"><a href=\"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/bladder-pumps-exceed-sampling-criteria\/\" style=\"color: #666;\">Continue Reading &raquo;<\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":852,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[450],"tags":[47,218,301,462],"class_list":["post-742","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-low-flow-groundwater-sampling","tag-low-flow-sampling","tag-nuclear-power","tag-groundwater-monitoring-program","tag-407-bladder-pump"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Bladder Pump Exceeds Sampling Criteria<\/title>\n<meta name=\"description\" content=\"A nuclear power facility in England has an extensive groundwater monitoring well network that requires regular sampling. Golder Associates, the project team who developed the network, wished to update their sampling equipment and protocols to improve efficiency, while maintaining accuracy and high safety standards.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/bladder-pumps-exceed-sampling-criteria\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Bladder Pump Exceeds Sampling Criteria\" \/>\n<meta property=\"og:description\" content=\"A nuclear power facility in England has an extensive groundwater monitoring well network that requires regular sampling. Golder Associates, the project team who developed the network, wished to update their sampling equipment and protocols to improve efficiency, while maintaining accuracy and high safety standards.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/bladder-pumps-exceed-sampling-criteria\/\" \/>\n<meta property=\"og:site_name\" content=\"On The Level Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/solinstcanada\/\" \/>\n<meta property=\"article:published_time\" content=\"2010-06-09T20:03:06+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2017-05-04T20:31:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2010\/06\/Bladder-Pumps-Used-at-Sensitive-Sites.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t<meta property=\"og:image:height\" content=\"362\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"solinst\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@solinstcanada\" \/>\n<meta name=\"twitter:site\" content=\"@solinstcanada\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"solinst\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/groundwater-sampling\\\/low-flow-groundwater-sampling\\\/bladder-pumps-exceed-sampling-criteria\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/groundwater-sampling\\\/low-flow-groundwater-sampling\\\/bladder-pumps-exceed-sampling-criteria\\\/\"},\"author\":{\"name\":\"solinst\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/#\\\/schema\\\/person\\\/48d40cfbd51a4a1c1d9d0d008f1f410e\"},\"headline\":\"Bladder Pumps Exceed Sampling Criteria\",\"datePublished\":\"2010-06-09T20:03:06+00:00\",\"dateModified\":\"2017-05-04T20:31:16+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/groundwater-sampling\\\/low-flow-groundwater-sampling\\\/bladder-pumps-exceed-sampling-criteria\\\/\"},\"wordCount\":304,\"image\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/groundwater-sampling\\\/low-flow-groundwater-sampling\\\/bladder-pumps-exceed-sampling-criteria\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/wp-content\\\/uploads\\\/2010\\\/06\\\/Bladder-Pumps-Used-at-Sensitive-Sites.jpg\",\"keywords\":[\"low flow sampling\",\"nuclear power\",\"groundwater monitoring program\",\"407 bladder pump\"],\"articleSection\":[\"Low Flow Groundwater Sampling\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/groundwater-sampling\\\/low-flow-groundwater-sampling\\\/bladder-pumps-exceed-sampling-criteria\\\/\",\"url\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/groundwater-sampling\\\/low-flow-groundwater-sampling\\\/bladder-pumps-exceed-sampling-criteria\\\/\",\"name\":\"Bladder Pump Exceeds Sampling Criteria\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/groundwater-sampling\\\/low-flow-groundwater-sampling\\\/bladder-pumps-exceed-sampling-criteria\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/groundwater-sampling\\\/low-flow-groundwater-sampling\\\/bladder-pumps-exceed-sampling-criteria\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/wp-content\\\/uploads\\\/2010\\\/06\\\/Bladder-Pumps-Used-at-Sensitive-Sites.jpg\",\"datePublished\":\"2010-06-09T20:03:06+00:00\",\"dateModified\":\"2017-05-04T20:31:16+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/#\\\/schema\\\/person\\\/48d40cfbd51a4a1c1d9d0d008f1f410e\"},\"description\":\"A nuclear power facility in England has an extensive groundwater monitoring well network that requires regular sampling. Golder Associates, the project team who developed the network, wished to update their sampling equipment and protocols to improve efficiency, while maintaining accuracy and high safety standards.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/groundwater-sampling\\\/low-flow-groundwater-sampling\\\/bladder-pumps-exceed-sampling-criteria\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/groundwater-sampling\\\/low-flow-groundwater-sampling\\\/bladder-pumps-exceed-sampling-criteria\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/groundwater-sampling\\\/low-flow-groundwater-sampling\\\/bladder-pumps-exceed-sampling-criteria\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/wp-content\\\/uploads\\\/2010\\\/06\\\/Bladder-Pumps-Used-at-Sensitive-Sites.jpg\",\"contentUrl\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/wp-content\\\/uploads\\\/2010\\\/06\\\/Bladder-Pumps-Used-at-Sensitive-Sites.jpg\",\"width\":350,\"height\":362},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/groundwater-sampling\\\/low-flow-groundwater-sampling\\\/bladder-pumps-exceed-sampling-criteria\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Bladder Pumps Exceed Sampling Criteria\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/#website\",\"url\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/\",\"name\":\"On The Level Blog\",\"description\":\"Water Monitoring News and Updates\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/#\\\/schema\\\/person\\\/48d40cfbd51a4a1c1d9d0d008f1f410e\",\"name\":\"solinst\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b63e3717450298404899da59ce8a579b1b2613f66f480d2016a3f334a946cd6d?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b63e3717450298404899da59ce8a579b1b2613f66f480d2016a3f334a946cd6d?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b63e3717450298404899da59ce8a579b1b2613f66f480d2016a3f334a946cd6d?s=96&d=mm&r=g\",\"caption\":\"solinst\"},\"url\":\"https:\\\/\\\/www.solinst.com\\\/onthelevel-news\\\/author\\\/solinst\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Bladder Pump Exceeds Sampling Criteria","description":"A nuclear power facility in England has an extensive groundwater monitoring well network that requires regular sampling. Golder Associates, the project team who developed the network, wished to update their sampling equipment and protocols to improve efficiency, while maintaining accuracy and high safety standards.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/bladder-pumps-exceed-sampling-criteria\/","og_locale":"en_US","og_type":"article","og_title":"Bladder Pump Exceeds Sampling Criteria","og_description":"A nuclear power facility in England has an extensive groundwater monitoring well network that requires regular sampling. Golder Associates, the project team who developed the network, wished to update their sampling equipment and protocols to improve efficiency, while maintaining accuracy and high safety standards.","og_url":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/bladder-pumps-exceed-sampling-criteria\/","og_site_name":"On The Level Blog","article_publisher":"https:\/\/www.facebook.com\/solinstcanada\/","article_published_time":"2010-06-09T20:03:06+00:00","article_modified_time":"2017-05-04T20:31:16+00:00","og_image":[{"width":350,"height":362,"url":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2010\/06\/Bladder-Pumps-Used-at-Sensitive-Sites.jpg","type":"image\/jpeg"}],"author":"solinst","twitter_card":"summary_large_image","twitter_creator":"@solinstcanada","twitter_site":"@solinstcanada","twitter_misc":{"Written by":"solinst","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/bladder-pumps-exceed-sampling-criteria\/#article","isPartOf":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/bladder-pumps-exceed-sampling-criteria\/"},"author":{"name":"solinst","@id":"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/48d40cfbd51a4a1c1d9d0d008f1f410e"},"headline":"Bladder Pumps Exceed Sampling Criteria","datePublished":"2010-06-09T20:03:06+00:00","dateModified":"2017-05-04T20:31:16+00:00","mainEntityOfPage":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/bladder-pumps-exceed-sampling-criteria\/"},"wordCount":304,"image":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/bladder-pumps-exceed-sampling-criteria\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2010\/06\/Bladder-Pumps-Used-at-Sensitive-Sites.jpg","keywords":["low flow sampling","nuclear power","groundwater monitoring program","407 bladder pump"],"articleSection":["Low Flow Groundwater Sampling"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/bladder-pumps-exceed-sampling-criteria\/","url":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/bladder-pumps-exceed-sampling-criteria\/","name":"Bladder Pump Exceeds Sampling Criteria","isPartOf":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/bladder-pumps-exceed-sampling-criteria\/#primaryimage"},"image":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/bladder-pumps-exceed-sampling-criteria\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2010\/06\/Bladder-Pumps-Used-at-Sensitive-Sites.jpg","datePublished":"2010-06-09T20:03:06+00:00","dateModified":"2017-05-04T20:31:16+00:00","author":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/48d40cfbd51a4a1c1d9d0d008f1f410e"},"description":"A nuclear power facility in England has an extensive groundwater monitoring well network that requires regular sampling. Golder Associates, the project team who developed the network, wished to update their sampling equipment and protocols to improve efficiency, while maintaining accuracy and high safety standards.","breadcrumb":{"@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/bladder-pumps-exceed-sampling-criteria\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/bladder-pumps-exceed-sampling-criteria\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/bladder-pumps-exceed-sampling-criteria\/#primaryimage","url":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2010\/06\/Bladder-Pumps-Used-at-Sensitive-Sites.jpg","contentUrl":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2010\/06\/Bladder-Pumps-Used-at-Sensitive-Sites.jpg","width":350,"height":362},{"@type":"BreadcrumbList","@id":"https:\/\/www.solinst.com\/onthelevel-news\/groundwater-sampling\/low-flow-groundwater-sampling\/bladder-pumps-exceed-sampling-criteria\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.solinst.com\/onthelevel-news\/"},{"@type":"ListItem","position":2,"name":"Bladder Pumps Exceed Sampling Criteria"}]},{"@type":"WebSite","@id":"https:\/\/www.solinst.com\/onthelevel-news\/#website","url":"https:\/\/www.solinst.com\/onthelevel-news\/","name":"On The Level Blog","description":"Water Monitoring News and Updates","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solinst.com\/onthelevel-news\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.solinst.com\/onthelevel-news\/#\/schema\/person\/48d40cfbd51a4a1c1d9d0d008f1f410e","name":"solinst","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/b63e3717450298404899da59ce8a579b1b2613f66f480d2016a3f334a946cd6d?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/b63e3717450298404899da59ce8a579b1b2613f66f480d2016a3f334a946cd6d?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/b63e3717450298404899da59ce8a579b1b2613f66f480d2016a3f334a946cd6d?s=96&d=mm&r=g","caption":"solinst"},"url":"https:\/\/www.solinst.com\/onthelevel-news\/author\/solinst\/"}]}},"jetpack_featured_media_url":"https:\/\/www.solinst.com\/onthelevel-news\/wp-content\/uploads\/2010\/06\/Bladder-Pumps-Used-at-Sensitive-Sites.jpg","_links":{"self":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts\/742","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/comments?post=742"}],"version-history":[{"count":5,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts\/742\/revisions"}],"predecessor-version":[{"id":2100,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/posts\/742\/revisions\/2100"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/media\/852"}],"wp:attachment":[{"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/media?parent=742"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/categories?post=742"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solinst.com\/onthelevel-news\/wp-json\/wp\/v2\/tags?post=742"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}