The TLC Meter uses a smart conductivity sensor with platinum electrodes to read conductivity from 0 80,000 µS. The conductivity is displayed on the rotating screen along with the associated temperature measurement. The smart conductivity probe displays conductivity automatically standardized to 25°C, i.e. specific conductance.
Calibration is simple, using 1413 µS and 80,000 µS solutions for single or two point conductivity calibration.
The TLC Meter operates in a range from 15°C to +50°C (23°F to 122°F). You may choose to have the readings displayed on the LCD screen in °C or °F. Accuracy is +/- 0.3°C in Celsius, or +/-0.5°F in Fahrenheit. Conductivity measurements are temperature sensitive. The smart TLC probe automatically adjusts the measured conductivity values to display as specific conductance. This provides standardized repeatably comparable measurements.
When the probe is turned on, the LCD screen displays both conductivity and temperature. A short wait of 20 seconds per degree Celsius of temperature change is required for the measurements to stabilize at each desired depth, before recording the three measurements.
|
|
|
|
When the zero point of the probe enters water, an electric circuit is completed, briefly activating a buzzer and blanking out the screen for about 1 second. The depth to water is then read off the tape. When the TLC Meter is withdrawn from the water, a short buzz gives a warning that the probe is now out of water.
A Tape Guide/Datum allows the depth measurement to be read at the marked position on the Tape Guide, to give reliable, repeatable, accurate depth measurements when profiling a well. The Tape Guide protects the tape from damage on rough edges of well casing.
|
|
|
|
The high quality polyethylene tape reels smoothly, remains flexible and hangs straight in the well, irrespective of temperature. The tape is mounted on a sturdy, well-balanced Solinst reel, with a convenient battery drawer for the 9 Volt alkaline battery. Permanent markings each 1/100 ft. or millimeter allow accurate readings.
Stranded stainless steel conductors resist corrosion, provide strength and are non-stretch. They make the tape very easy to repair and splice. The dog-bone design reduces adherence to wet surfaces.
M2: Each 1/100 ft. and 1/10 ft. in black; feet in red
M3: Each millimeter in black; meters in red
Lengths: 100 ft., 150 ft., 300 ft., (30 m, 50 m, 100 m)
|
| |
|
| |
|
|