solinst  groundwater samplers  dedicated pumps  dedicated sampling pumps  monitoring cmt systems  peristaltic pumps  micro double valve pumps  water level meters  water level indicators image
  .
solinst  groundwater samplers  dedicated pumps  dedicated sampling pumps  monitoring cmt systems  peristaltic pumps  micro double valve pumps  water level meters  water level indicators image  

Model 403 CMT Multilevel System*


Water levels and samples can be accurately obtained using the following quality Solinst instruments:

 

Water Levels:

solinst  groundwater samplers  dedicated pumps  dedicated sampling pumps  monitoring cmt systems  peristaltic pumps  micro double valve pumps  water level meters  water level indicators image
Model 102
Water Level Meter

The narrow coaxial cable Model 102 Water Level Meter with the 1/4" (6.4 mm) diameter probe is ideal for taking water level measurements in either CMT System.

top 

Samples:

solinst  groundwater samplers  dedicated pumps  dedicated sampling pumps  monitoring cmt systems  peristaltic pumps  micro double valve pumps  water level meters  water level indicators image
Model 410
Peristaltic Pump

Groundwater sampling can be performed using the Solinst Peristaltic Pump, which has a suction lift limit of approximately 25 ft (7.5 m).

solinst  groundwater samplers  dedicated pumps  dedicated sampling pumps  monitoring cmt systems  peristaltic pumps  micro double valve pumps  water level meters  water level indicators image
Mini Inertial Pump
1/4" (6mm)

The Mini Inertial Pump can be used with inexpensive polyethylene tubing to depths of 50 ft. (15 m), or using Teflon® tubing to depths of 150 ft. (45 m).

solinst  groundwater samplers  dedicated pumps  dedicated sampling pumps  monitoring cmt systems  peristaltic pumps  micro double valve pumps  water level meters  water level indicators image
Model 408M DVP
3/8" (9.5 mm)

The Micro Double Valve Pump (DVP) is ideal for low flow VOC sampling in narrow applications. The Micro DVP is made of flexible Teflon® or polyethylene tubing which is 3/8” (9.5 mm) in diameter.

solinst  groundwater samplers  dedicated pumps  dedicated sampling pumps  monitoring cmt systems  peristaltic pumps  micro double valve pumps  water level meters  water level indicators image
Model 466
Electronic Control

A manifold at the surface has a quick-connect fitting for attachment to the Solinst Electronic Control Unit and a bypass for easy sample collection. Operation is easy, as the Electronic Control Unit has built in pre-sets. A multi-purge manifold is also available for the Micro DVP.

top 

Vapor Samples:

solinst  groundwater samplers  dedicated pumps  dedicated sampling pumps  monitoring cmt systems  peristaltic pumps  micro double valve pumps  water level meters  water level indicators image
Model 403
Vapor Wellhead

A special Vapor Wellhead Assembly can be used to obtain depth discrete vapor samples.

top 

 
 

CMT Multilevel - Monitoring Options

Measuring Water Levels

Depth to
Water (ft)

Level Measurement Device

Flowing

Flow Through Assembly consisting of:

3 way valve to: pressure gauge, sample tube, & stop flow.

0 to 25

101M - P1 with 1/4" probe.

0 to 300+ft.

102 - P1 with 1/4" probe.


Purging & Sampling

Depth to
Water (ft)

Pump Type

Suggested Tubing

Typical Flow Rates
(mL/min)

< 25

410 Peristaltic Pump

1/4" LDPE

100 to 3000

< 50

Mini Inertial Pump

1/4" LDPE

250

50 to 200

Mini Inertial Pump

1/4" Teflon

50 to 250

< 50

408m Double Valve Pump

3/8" LDPE
& 3/16" Teflon

250

50 to 200

408m Double Valve Pump

3/8" LDPE
& 3/16" Teflon

50 to 250

 
 